ASSEMBLY INSTRUCTIO
N
S
1.
Find the cast aluminum base legs. One at a time, with the hollow side facing down,
place three base legs around the bottom of the yoke tube. Note: either end of tube
can be top or bottom. As you place the legs around the tube, simultaneously insert
the hex head bolts into the pass through holes on each of the base leg. Slide on
the lock washer and hand tighten the hex nuts. Using a 1/2" socket, nut driver or
open end wrench. Proceed to
a
lternately tighten each bolt. To prevent gaps be-
tween the legs do not tighten any one bolt completely, tighten bolts equally.
2.
Next Insert 3 casters into the base legs. Occasionally the base leg through hole
may accumulate excess powder coating, making it difficult to insert casters. Light
filing with a rattail file can be used to clean excess coating. Slide the height collar
ring onto the yoke tube, followed by the height collar washer. Then insert the yoke
into the base insert tube. Screw in the height collar handle and raise or lower to
desired height and lock handle into place.
3.
Slide the small
fiber friction washer followed by the sleeve bearing and
then the
large friction washers onto the threaded stud of the adjustable tilt handle. Thread
handle into the bail until it is flushed to the yoke weld nut
on the other side of the
bail. Spread washers fully apart so that the yoke can be
inserted between them.
4.
Lift the
Ichip Mystére
using the front and rear
black carry Handles
located on
both sides of the chassis.
Position
the bail handle shafts in the U-shaped slots at
the top of the yoke. Ensure that the
washers are positioned properly. Turn the tilt
lock handles to tighten the grip on the
yoke. Push the button on the tilt handle for
suitable handle positioning.
5.
T
he two zinc plated steel control shafts
have been threaded on and secured
a
t
the factory, hand tighten the
two black control knobs
onto the shaft, The Iris and
douser are ready for operation
.
The shafts have flat cut outs at one end of the
shaft
.
Us
e
an
open end wrench
to
tighten the shafts securely. A nyloc nut and
washer are supplied to fully secure shaft. Next, unscrew the two 1/4-20 phillips
head shipping screws and washers, remove and save screws for future shipping
use if needed. Slide the metal washer (first) and then the fibre lens washer onto
the threaded stud of the lens handles. Insert and hand tighten to lock down
(clockwise) and loosen to operate (counterclockwise).
6.
Lastly, Screw the two black control knobs onto the iris and dowser control
shaft
to complete the assembly process. The Ichip Mystére is now ready for
operation.
Ichip Mystére
I
C
M-
150
/120 User Manual
3