Tel:
+44 (0)1274 657 088
Fax:
+44 (0)1274 657 087
Web:
www.phoebeled.com
Images are for information only. Phoebe LED shall not be held liable for improper operation of the luminaire in circumstances where procedures and
specifications have not been followed correctly.
Brown =
Live
Green/Yellow =
Earth
Blue =
Neutral
Black =
Live-Out
Brown =
Live
Green/Yellow =
Earth
Blue =
Neutral
Black =
Live Out
Brown =
Live
Green/Yellow =
Earth
Blue =
Neutral
To 240V Mains
To 240V Mains
LO
Live-Out unused
for single fitting
L-OUT black
L-IN
brown
N blue
E yellow/green
AC220-240V
L
N
E
Terminal
Box
Terminal
Box
Terminal
Box
Power < 180W
* Max. power load of a sensor is 180W
.
L brown
N blue
E yellow/green
L brown
N blue
E yellow/green
4 PIN terminal
AC220-240V
L-OUT
L
L
E
N
N
E
L-IN
E
N
3 PIN terminal
AC220-240V
L
L
E
N
N
E
L
N
E
This wiring diagram relevant to Phoebe LED Atlas-Mini LED Slimline
Floodlights with part codes:
6416, 6430, 6454, 7581, 10314, 10338, 10352, 10376
This wiring diagram relevant to Phoebe LED Atlas-Mini LED Slimline Floodlights with part codes:
6416, 6423, 6430, 6447, 6454, 6461, 7581, 7598, 10314, 10321, 10338, 10345, 10352, 10369, 10376, 10383
This wiring diagram relevant to Phoebe LED Atlas-Mini LED Slimline
Floodlights with PIR sensor part codes:
6423, 6447, 6461, 7598, 10321, 10345, 10369, 10383
Single Standard Atlas-Mini
Single PIR Sensor Atlas-Mini
Controlling multiple luminaires with one PIR sensor model
WIRING DIOGRAMS