background image

4

SAFETY PRECAUTIONS

This label may appear on the bottom of the unit due to space
limitations.

The lightning flash with an arrowhead symbol within
an equilateral triangle is intended to alert the user to
the presence of uninsulated "dangerous voltage" within
the product's enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons. 

The exclamation point within an equilateral triangle is
intended to alert the user to presence of important
operating and maintenance (servicing) instructions in
the literature accompanying the appliance.

Attention:  Installation should be performed by
qualified service personnel only in accordance with the
National Electrical Code or applicable local codes.

Power Disconnect. Units with or without ON-OFF
switches have power supplied to the unit whenever the
power cord is inserted into the power source; however,
the unit is operational only when the ON-OFF switch
is in the ON position. The power cord is the main
power disconnect for all units.

SECURITE

En raison d’une limitation de la place disponible, il est possible
que cette étiquette soit apposée sur le dessous de l’appareil.

L’éclair fléché dans un triangle équilatéral avertit
l’utilisateur de la présence d’une “tension dangereuse” non
isolée à l’intérieur de l’appareil et d’une valeur suffisante
pour présenter un risque d’électrocution aux personnes.

Le point d’exclamation contenu dans un triangle
équilatéral avertit l’utilisateur de la présence de
consignes d’utilisation et de maintenance importantes
dans la documentation qui accompagne l’appareil.

Attention

.

L’installation ne doit être effectuée que par

un personnel technique qualifié conformément à la
réglementation du Code Électrique National ou à la
réglementation locale pertinente.

Disjonction de l’alimentation. Les appareils avec ou sans
commutateurs ON-OFF sont alimentés à chaque fois
que le cordon d’alimentation est branché à la source
d’alimentation; toutefois, les appareils disposant de
commutateurs ON-OFF ne fonctionnent que lorsque le
commutateur ON-OFF est dans la position ON. Le
cordon d’alimentation constitue le moyen de disjonction
de l’alimentation principale de tous les appareils.

CAUTION: TO REDUCE THE RISK OF
ELECTRICAL SHOCK, DO NOT OPEN
COVERS. NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

WARNING
TO PREVENT FIRE OR SHOCK HAZARD, DO
NOT EXPOSE UNITS NOT SPECIFICALLY
DESIGNED FOR OUTDOOR USE TO RAIN OR
MOISTURE.

ATTENTION

RISQUE D’ÉLECTROCUTION. 

NE PAS OUVRIR !

DANGER : POUR ÉVITER TOUT RISQUE
D’ÉLECTROCUTION, VEUILLEZ NE PAS
OUVRIR LE BOÎTIER. IL N’Y A PAS DE
PIÈCES REMPLAÇABLES PAR L’UTILISATEUR
À L’INTÉRIEUR DU BOÎTIER. POUR TOUTE
MAINTENANCE, VEUILLEZ VOUS ADRESSER
À UN TECHNICIEN SPÉCIALISÉ.

ATTENTION 
POUR ÉVITER TOUT RISQUE
D’ÉLECTROCUTION OU D’INCENDIE,
VEUILLEZ NE PAS EXPOSER À LA PLUIE OU
À L’HUMIDITÉ UN APPAREIL NON CONÇU
POUR UNE UTILISATION EXTÉRIEURE.

Summary of Contents for VidQuad LTC 2372

Page 1: ...LTC 2372 LTC 2375 LTC 2376 LTC 2377 VidQuad DigitalVideo Processors Installation Instructions Philips Communication Security Imaging Eng B Series ...

Page 2: ...2 ...

Page 3: ...s that could result in a fire or electric shock Never spill liquid of any kind on the unit 16 Servicing Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 17 Damage Requiring Service Unplug the unit from the outlet and refer servicing to qualified service personnel under ...

Page 4: ...ctrocution aux personnes Le point d exclamation contenu dans un triangle équilatéral avertit l utilisateur de la présence de consignes d utilisation et de maintenance importantes dans la documentation qui accompagne l appareil Attention L installation ne doit être effectuée que par un personnel technique qualifié conformément à la réglementation du Code Électrique National ou à la réglementation l...

Page 5: ...magnitud suficiente como para presentar un riesgo de descarga eléctrica para las personas El punto de exclamación dentro de un triángulo equilátero pretende alertar al usuario de la existencia de instrucciones de funcionamiento y mantenimiento reparación en la documentación suministrada con el aparato Atención La instalación debe realizarla personal cualificado en cumplimiento estricto del código ...

Page 6: ...iciente per costituire pericolo di elettrocuzione Il punto esclamativo racchiuso in un triangolo equilatero intende avvisare l utente in merito alla presenza di importanti istruzioni operative e di manutenzione nella documentazione di accompagnamento all unità Precauzione affidare l installazione al solo personale qualificato e nel rispetto del Codice elettrico nazionale USA o dei codici locali pe...

Page 7: ...els LTC 2372 60 120 VAC 60 Hz 105 to 135 4 W EIA LTC 2372 50 230 VAC 50 Hz 210 to 260 4 W CCIR LTC 2376 60 120 VAC 60 Hz 105 to 135 4 W EIA LTC 2376 50 230 VAC 50 Hz 210 to 260 4 W CCIR Color Models LTC 2375 60 120 VAC 50 60 Hz 100 to 240 6 W NTSC LTC 2375 50 230 VAC 50 60 Hz 100 to 240 6 W PAL LTC 2377 60 120 VAC 50 60 Hz 100 to 240 6 W NTSC LTC 2377 50 230 VAC 50 60 Hz 100 to 240 6 W PAL 1 One 1...

Page 8: ...SS II MON PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS GND ALARM REMOTE 1 2 3 4 CLASS II MON VCR IN MADE IN KOREA OUT 1 2 3 4 VCR or DVR In Out 1 8 9 15 Alarm Auto terminating Video Loop Outputs PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS GND Figure 2 Configuration for LTC 2376 LTC 2377 VidQuad Digital Processor Unit with Monitor Option ...

Page 9: ...hielded and the shield must be grounded NOTES 1 The LTC 2377 provides a COLOR Adjustment menu to assist initial monitor adjustment 2 If the video line ends at the system monitor set the monitor s termination switch to 75 Ohm If the video is looped through the monitor to some other item of equipment set the monitor termination switch to HIGH Z or HIGH IMPEDANCE The last video in the line must be te...

Page 10: ...e the effects of image interference Attach a wire compliant with local codes between the grounding screw on the rear panel and a suitable earth ground Table Key Functions Key Label Operating Function Programming Function VCR Selects VCR input for display on monitor NONE Menu Selects on screen menu Enter the programming mode Seq Selects the sequential switching function NONE 1 Selects camera 1 for ...

Page 11: ...the required position Press the and keys to establish the necessary digit calenders until the year of 2097 are in this menu Press the key 5 3 4 Display Mode Set Select the DISPLAY function Press the key to toggle through BOTTOM TOP and OFF The Date Time will be displayed on the monitor in the selected position Select EXIT and press the key to exit the menu 5 4 Camera Sequence Setup This menu allow...

Page 12: ... 5 2 Alarm Dwell Time The ALARM DWELL function allows you to set the automatic reset period after an alarm is generated Select ALARM DWELL and press the key The following menu is displayed Press the and keys to adjust the time Options are as follows 1 60 SEC automatic reset period HOLD alarm continues until the alarm camera key is pressed followed by the key FOLLOW alarm continues until the alarm ...

Page 13: ...mode or as the selected monitor output Select VCR OUT MODE and press the key The following menu is displayed Press the and keys to toggle the mode for the following DISPLAY QUAD ONLY the output to the VCR DVR will be quad mode in all conditions SAME AS MONITOR OUT the VCR output will be the same as the selected monitor output Press the key to exit the menu 5 7 Camera Titles You can set up camera t...

Page 14: ...ividual camera input for optimum display Key codes used for adjusting are as follows Change option Increase Decrease Advance camera Select COLOR ADJUST and press the key The following menu is displayed Press the and keys to adjust the brightness to display the optimum image Press the key to display the next menu Press the and keys to adjust the contrast to display the optimum image Press the key t...

Page 15: ...igit password Press the key to exit the menu Select EXIT to exit the main menu Attempt to access the Menu by pressing Menu Enter your 4 digit password When a correct password is entered the main menu is displayed If incorrect the message Wrong Password is displayed for 3 seconds and will then display the camera images 5 9 1 Disable Password The password function can be disabled Select DISABLE PASS...

Page 16: ...unction is selected 3 The VCR DVR images can be viewed as recorded in a quad format or any quad can be zoomed to full screen Press the 1 key The upper left hand quad is zoomed to full screen Press the 2 key The upper right hand quad is zoomed to full screen Press the 3 key The lower left hand quad is zoomed to full screen Press the 4 key The lower right hand quad is zoomed to full screen Press the...

Page 17: ...l the alarm is reset by the operator Press the key to cancel the alarm If an Alarm Dwell Time is set to the FOLLOW mode the alarm remains active until the alarm is reset Press the key to cancel the alarm instantly 6 2 7 Video Loss Alert The LTC 2376 and LTC 2377 may be programmed to produce an alarm if the video signal to any of the four camera channels is lost NOTE Video Loss Alert must be ON for...

Page 18: ...LES Display as CH1 CH2 CH3 CH4 VCR OUT MODE Set up as Same as Monitor Out mode LTC 2376 always Quad Only mode ALARM SETUP Alarm Channels are all ON and Video Loss Channels are all OFF Dwell Time is set up as 5 sec Alarm input polarities are all normally open NO SEQ SETUP Each 2 seconds 1 4 and Quad TIME DATE Time and Date are not changed Format is set up as MM DD YEAR PASSWORD SET Password is disa...

Page 19: ...19 ...

Page 20: ...2 09 2002 Philips Electronics N V Printed In U S A 2002 Philips Communication Security Imaging Inc All Rights Reserved Philips is a registered trademark of Philips Electronics N V Data subject to change without notice ...

Reviews: