Philips 1
5
⁄
8
" T8 U-Bent Lamps featuring ALTO
®
Lamp Technology
Ordering, Electrical and Technical Data
(Subject to change without notice.)
Color
Nom.
Rated Average Life (hrs.)
Approx.
Product
Ordering
Pack.
Temp.
Leg
Length
3-hr on
12-hr on
Initial
Design
Lumen
Number
Watts
Code
Qty.
(Kelvin)
Spacing
(In.)
Ins. Start
1
Ins. Start
2
Lumens
3
Lumens
4
CRI
Maint.
22675-3
29
FB29T8/TL830/EA/ALTO
15
3000K
1
5
⁄
8
"
22
3
⁄
5
24,000
30,000
2600
2470
85
95%
22676-1
29
FB29T8/TL835/EA/ALTO
15
3500K
1
5
⁄
8
"
22
3
⁄
5
24,000
30,000
2600
2470
85
95%
22677-9
29
FB29T8/TL841/EA/ALTO
15
4100K
1
5
⁄
8
"
22
3
⁄
5
24,000
30,000
2600
2470
85
95%
22671-2
31
FB31T8/TL830/ALTO
15
3000K
1
5
⁄
8
"
22
3
⁄
5
24,000
30,000
2775
2636
85
95%
22672-0
31
FB31T8/TL835/ALTO
15
3500K
1
5
⁄
8
"
22
3
⁄
5
24,000
30,000
2775
2636
85
95%
22674-6
31
FB31T8/TL841/ALTO
15
4100K
1
5
⁄
8
"
22
3
⁄
5
24,000
30,000
2775
2636
85
95%
1) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
2) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 12 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
3) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under
standard laboratory conditions.
4) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under
standard laboratory conditions.
0
0
10,000
10,000
20,000
20,000
30,000
30,000
40,000
40,000
Rated Average Life in Hours
Rated Average Life in Hours
BASED ON 3 HOURS PER START
1
Programmed Start Ballast
Instant Start Ballast
24,000
30,000
30,000
36,000
BASED ON 12 HOURS PER START
2
Rated Average Life
Philips 1
5
⁄
8
" T8 U-Bent Lamps
P-5987 1_5-8 UBent Product Bulletin:Layout 1 1/6/09 1:20 PM Page 2