background image

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

Philips T8 Lamps featuring ALTO II

Technology

Ordering, Electrical and Technical Data

Color

Nom.

Rated Average Life (hrs)

1

Approx.

Product

Ordering

Pack.

Temp.

Length

12-hr on

12-hr on

Initial

Design

Lumen

Number

Code

Watts

Qty.

(Kelvin)

(In.)

Ins. Start

Prog. Start

Lumens

2

Lumens

3

CRI

Maint.

36787-0

F17T8/TL830/ALTO

17

25

3000

24

30,000

36,000

1400

1330

85

95%

36791-2

F17T8/TL835/ALTO

17

25

3500

24

30,000

36,000

1400

1330

85

95%

36793-8

F17T8/TL841/ALTO

17

25

4100

24

30,000

36,000

1400

1330

85

95%

14123-4

F17T8/TL850/ALTO

17

25

5000

24

30,000

36,000

1325

1260

82

95%

36807-6

F17T8/TL730/ALTO

17

25

3000

24

30,000

36,000

1325

1260

78

95%

36808-4

F17T8/TL735/ALTO

17

25

3500

24

30,000

36,000

1325

1260

78

95%

36812-6

F17T8/TL741/ALTO

17

25

4100

24

30,000

36,000

1325

1260

78

95%

36813-4

F25T8/TL830/ALTO

25

25

3000

36

30,000

36,000

2225

2115

85

95%

36814-2

F25T8/TL835/ALTO

25

25

3500

36

30,000

36,000

2225

2115

85

95%

36825-8

F25T8/TL841/ALTO

25

25

4100

36

30,000

36,000

2225

2115

85

95%

14124-2

F25T8/TL850/ALTO

25

25

5000

36

30,000

36,000

2150

2040

82

95%

36826-6

F25T8/TL730/ALTO

25

25

3000

36

30,000

36,000

2125

2020

78

95%

36828-2

F25T8/TL735/ALTO

25

25

3500

36

30,000

36,000

2125

2020

78

95%

36829-0

F25T8/TL741/ALTO

25

25

4100

36

30,000

36,000

2125

2020

78

95%

24667-8

F32T8/TL830/ALTO

32

25

3000

48

30,000

36,000

2950

2800

85

95%

24670-2

F32T8/TL835/ALTO

32

25

3500

48

30,000

36,000

2950

2800

85

95%

24671-0

F32T8/TL841/ALTO

32

25

4100

48

30,000

36,000

2950

2800

85

95%

27229-4

F32T8/TL850/ALTO

32

25

5000

48

30,000

36,000

2850

2700

82

95%

27252-6

F32T8/TL730 ALTO

32

25

3000

48

30,000

36,000

2800

2660

78

95%

27249-2

F32T8/TL735/ALTO

32

25

3500

48

30,000

36,000

2800

2660

78

95%

27248-4

F32T8/TL741/ALTO

32

25

4100

48

30,000

36,000

2800

2660

78

95%

38351-3

F32T8/TL741/ALTO

32

10

4100

48

30,000

36,000

2800

2660

78

95%

27268-2

F32T8/TL750/ALTO

32

25

5000

48

30,000

36,000

2700

2565

78

95%

Specifications are subject to change without notice.
© 2007 Philips Lighting Company. All rights reserved.
Printed in USA 06/07

P-5338-G

www. philips.com

Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050

A Division of Philips Electronics North America Corporation

Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050

A Division of Philips Electronics Ltd.

1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
2) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory

conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a
multiplier applied to the designated lamp lumen output.

3) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under

standard laboratory conditions.

* It’s anticipated that lamp will be available Quarter 1, 2008.

Lamp meets US Federal Minimum Efficiency Standards.

This lamp is better for the environment because of its reduced mercury content. All Philips ALTO II

lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state

and local regulations.

E

0

10,000

20,000 30,000 40,000 50,000

 

0

10,000

20,000 30,000 40,000 50,000

Rated Average Life in Hours

Rated Average Life in Hours

BASED ON 3 HOURS PER START

4

Programmed Start Ballast

Instant Start Ballast

24,000

30,000

30,000

36,000

BASED ON 12 HOURS PER START

1

Rated Average Life

Philips T8 Lamps

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

40,000

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

40,000

100%

98%

96%

94%

92%

90%

100%

98%

96%

94%

92%

90%

Lamp Operating Hours

Lamp Operating Hours

Li

gh

t

O

ut

pu

t

(%

)

Li

gh

t

O

ut

pu

t

(%

)

95% Lumen Maintenance

Philips T8 Lamps

E

E

E

E

E

E

E

E

E

4) Average life under specified test conditions with lamps turned off

and restarted no more frequently than once every 3 operating hours.
Lamp life is appreciably longer if lamps are started less frequently.