Mount the sPDS-60ca

Make sure the sPDS-60ca device is powered OFF before mounting and connecting. A 
power screwdriver is recommended.

1.    Position the sPDS-60ca device in its designated mounting location. Make sure the 

mounting location is 

fl

 at, suitable for the mounting hardware, and clear of debris 

and other obstructions.

2.    Using four M3.5 or #6 screws suitable for the mounting surface, secure the 

sPDS-60ca device to the surface using the two mounting slots located at both 
ends of the device.

Install EMI Suppression Cores

The sPDS-60ca ships with three EMI suppression cores.

 

These suppression cores 

reduce electromagnetic noise that can interfere with other electrical equipment. 
The white suppression cores are for Flex strands or 

fi

 xture leader cables. The black 

suppression core is for the IEC power cable.

Before attaching the cores, make sure that each set of ferrite metal halves are secure 
in their plastic housing.

1.    Attach the black suppression core to the power cable: 

•  Near the end of the cable that connects to the power / data supply, coil the 

IEC power cable into a small loop.

•  Place the section of the loop where the cord is doubled into the suppression 

core. Be sure the cord is securely in the core’s middle.

•  Snap the core shut around the doubled cord.

2.    Attach a white suppression core to the 

fi

 xture strand or leader cable attached 

to port 1.

•  Near the connection to the power / data supply, coil the strand or cable into 

a small loop.

•  Place the section of the loop where the cord is doubled into the suppression 

core. Be sure the cord is securely in the core’s middle.

•  Snap the core shut.

3.    Repeat step 2 for the second white suppression core, if necessary.

E

 

Make sure that there is adequate 

space to make all connections to the front 
and rear of the device. Also, the vents at 
the top and rear of the device should not 
be obstructed.

E

 

Make sure that the device is securely 

attached to the mounting surface and free 
of excessive vibration.

8.8 in

(224 mm)

8.3 in

(211 mm)

2.3 in

(58 mm)

4.0 in

(102 mm)

DMX IN

ENET IN

OUT 2

AL

T

DA

TA

DMX OUT

Summary of Contents for sPDS-60ca

Page 1: ...sPDS 60ca Compact power data supply for low voltage linear fixtures ...

Page 2: ...de via an external panel for reduced installation time Short circuit protection prevents failure due to incorrectly wired fixtures Onboard push button controls offer the ability to address all connected fixtures eliminating the need for additional addressing tools or software The sPDS 60ca 24 V enclosure is designed for use in dry locations Compatible Fixtures sPDS 60ca 24 V is a compact power dat...

Page 3: ...t IEC 320 receptacle type C13 locking clamp Temperature Ranges 14 104 F 10 40 C Operating 14 122 F 10 50 C Startup 40 176 F 40 80 C Storage Humidity 0 95 non condensing Cooling Thermostatically controlled fan Airflow Top cover input back panel output Heat Dissipation 25 of total power input at maximum load Data Input Philips full range of controllers third party DMX controllers or KiNET compatible...

Page 4: ...n that shows the physical layout of the installation and identifies the locations of all lighting fixtures power data supplies controllers switches and cables DMX and Ethernet Configurations sPDS 60ca can be used in either DMX or Ethernet networks DMX is appropriate for relatively simple installations or for installations in which groups of lights operate in unison for example for accent lighting ...

Page 5: ...amp attached to the housing sPDS 60ca should be installed in a dry location Inspect sPDS 60ca and Accessories Carefully inspect the box containing the sPDS 60ca and the contents for any damage that may have occurred in transit Assemble Additional Items The following items are required to mount and connect the sPDS 60ca The included RJ45 terminator required in DMX lighting networks The included IEC...

Page 6: ...r plastic housing 1 Attach the black suppression core to the power cable Near the end of the cable that connects to the power data supply coil the IEC power cable into a small loop Place the section of the loop where the cord is doubled into the suppression core Be sure the cord is securely in the core s middle Snap the core shut around the doubled cord 2 Attach a white suppression core to the fix...

Page 7: ...hernet Using a CAT 5 cable connect the ETHERNET IN port on the sPDS 60ca to an available port on an Ethernet switch connected to your lighting network Connect Fixtures to the sPDS 60ca Make sure the power is OFF before connecting fixtures to the sPDS 60ca Connect a Flex strand or fixture leader cable to one of the two available ports on the front of the sPDS 60ca Connect the sPDS 60ca to Line Powe...

Page 8: ...em Manager Pro Ethernet lighting controllers from Philips Color Kinetics also automatically discover and address all connected fixtures For complete details on addressing and on using QuickPlay Pro refer to the Addressing and Configuration Guide available at www colorkinetics com support addressing Using the On Board Menu The sPDS 60ca has two buttons and a three digit display that allow you to di...

Page 9: ...wo nodes With a group setting of 02 each pair of consecutive nodes receives the same light number A group setting of 03 means that each group contains three consecutive nodes and so on The maximum group size is 20 nodes but you can set a group setting of ALL to assign the same light number to all connected nodes all nodes work in unison For Ethernet based video displays in which each fixture node ...

Page 10: ...ng the sequence of assigned light numbers begins at the end of the series of nodes connected to port 1 continues to the node nearest to port 1 picks up at port 2 and continues to the end of the series of nodes connected to port 2 To change the group setting 1 Press the menu s Up and Down buttons simultaneously The display shows the number of lights on each port as described in Discovering Nodes ab...

Page 11: ...sPDS 60ca Product Guide 11 ...

Page 12: ...ither registered trademarks or trademarks of Philips Solid State Lighting Solutions Inc in the United States and or other countries All other brand or product names are trademarks or registered trademarks of their respective owners Due to continuous improvements and innovations specifications may change without notice Cover Photo Peeps Company by Mark Philips Color Kinetics 3 Burlington Woods Driv...

Reviews: