background image

Service Manual

Philips Domestic Appliances and Personal Care

Published by Philips Domestic Appliances and Personal Care 

Printed in the Netherlands 

© Copyright reserved 

Subject to modification

 

 

Coffee Maker Senseo

HD7842

07/09

PRODUCT INFORMATION

-  This product meets the requirements regarding 

interference suppression on radio and TV.

-  After the product has been repaired, it should function 

properly and has to meet the safety requirements as 
officially laid down at this moment.

TECHNICAL INFORMATION

-  Voltage 

:  220 - 240 V

-  Frequency 

:  50 - 60 Hz

- Power consumption 

: 1450 W

-  Standby power consumption  : 

<

 1 W

- Contents reservoir 

: 1200 cc

-  Variable Coffee volume 

:  (Min, Normal and Max)

Coffee volume overview

Min cc/mL

Normal cc/mL

Max cc/mL

France version

80

100

140

General version

80

122

145

-  Colour setting 

:  Black / Aluminium

- Sap coding 

: HD7842

CONTROL

PCB

L

N

Boiler

Pump M

Fuse

Temp.
Sensor

Water level
sensor S1

Water level

sensor S2

Push buttons

 Display 

PCB

Fuse

calc clean

Summary of Contents for Senseo HD7842

Page 1: ...uld function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power consumption 1450 W Standby power consumption 1 W Contents reservoir 1200 cc Variable Coffee volume Min Normal and Max Coffee volume overview Min cc mL Normal cc mL Max cc mL France version 80 100 140 General version 80 122 145 Colour ...

Page 2: ...rease with 10 cc for example push the 2 cup button 3 times The new value will be stored when you switch the appliance off by pushing the main switch LED will turn off 12 Turn appliance on again and brew one cup measure the volume In case the volume is not within specification repeat steps 7 12 13 End To remove the back cover follow below steps Remove Screw A see exploded view Remove valve outlet S...

Page 3: ... main switch LED should light continuously Pos Service code Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 4222 259 42510 4222 259 42520 4222 247 42550 4222 247 52650 4222 259 37910 4222 240 05940 4222 247 41860 4222 247 59790 4222 247 41950 4222 247 06810 4222 240 05990 4222 247 41920 4222 259 37900 4222 259 34970 4222 259 35470 4222 247 05320 4222 259 3690...

Page 4: ...HD7842 4 5 EXPLODEDVIEW 10 12 11 4 3 5 1 2 7 6 9 8 13 Warning Live Voltage applied alway disconnect plug from the mains when repairing B B X ...

Page 5: ...HD7842 5 5 EXPLODEDVIEW X A 20 21 28 17 27 15 16 14 18 19 23 24 25 26 22 ...