HD7842
2-5
Volume adjustment
The new PCB circuit board makes it possible to adjust the
volume output by means of pushing the one-cup and two-cup
user controls.
How to adjust the volume output:
1. Be sure the boiler is fi lled properly, other wise perform fi ll
procedure see DFU for instructions.
2. Switch appliance on and wait until the unit is ready to
brew.
3. With volume selection knob be sure to select
normal cup volume (2 stripes on display, see picture)
4. Be sure a
pod holder
is placed, but
without
a Coffee
POD. (Only adjusting with
plain
water)
5. Place a cup on the drip tray cover and push the one-cup
button.
6. When the appliance has fi nished it is stabilized to perform
the volume adjustment.
7. Empty the cup, podholder and push again for one cup
setting, measure the volume output with a graduated
beaker. In the table you can fi nd the requirements for
the minimum / maximum volume output cc/mL values
depending from the country version:
One-cup setting (2 stripes Display setting),
Including Pod holder,
water spec
. (Without Coffee pod)
Min. water cc/mL
Max. water cc/mL
France version
104
120
General version
125
141
8. Unplug the appliance from the mains.
9. Press the 1- and 2 cup button simultaneously and plug the
mains on.
10. When above step succeeded the LED will turn on
continuously and the display will show the Tank
empty symbol. (see picture.)
11. Depending if the volume has to de- or increase you have
to push the 1- or 2 cup button.
Every time you push the 1- or 2 cup button the LED will
turn off for 0.5 second (feedback to user) and the pump
time will be shortened or lengthened for 0.5 seconds
depending which button was pushed.
Pushing 1 cup
button pump, time will be
shorten
with
0.5 sec is approximately − 3.5 cc/mL (less coffee)
Pushing 2 cup
button pump, time will be
lengthen
with
0.5 sec is approxi 3.5 cc/mL (more coffee)
When the volume has to increase with 10 cc for example,
push the
2 cup
button 3 times.
The new value will be stored when you switch the
appliance off by pushing the main switch.
(LED will turn off )
12. Turn appliance on again and brew one cup, measure the
volume. In case the volume is not within specifi cation
repeat steps 7 - 12.
13. End .
To remove the back cover, follow below steps:
- Remove Screw
A
(see exploded view).
- Remove valve outlet.
- Start at the upper side of the back cover and stick a
screwdriver into the 2 snap locks positions and gently pull
the back cover from the appliance so that a little chink
between back cover and brew chamber becomes visible.
- Put the screwdriver into the 4 rectangular holes (snap locks)
at the back and gently pull the screwdriver such away that
the lips of the snap locks are bent outwards.
- If all clicks positions are loose, it is possible to remove the
back cover.
- Reassemble follow steps backwards.
To reach the components placed on the base (for example
exchange the NTC temperature sensor) follow below steps:
- First remove back cover, brew chamber, 3-way valve and
boiler.
- Remove both Torx T15 screws
B
(see exploded view).
- Bend the 2 click snap locks with a screwdriver (see base),
the housing can now be removed.
- To remove the rest of the housing unlock the last 4 snap
locks at the base and gently pull of the front cover.
- To reassemble follow above steps backwards.
OPTIONAL (accessories)
-
No specific issues.
REPAIR INSTRUCTION
Descaling
Regular descaling will prolong the life of your appliance and
will guarantee optimal brewing results for a long time.
• Follow the steps in the section headed “Preparing the
appliance for use” see DFU (Direction for Use manual)
• Instead of only water use a mix of water and Lemon sour.
• For the best result leave the mix of water and Lemon sour
for about 30 Minutes in the appliance, before you start with
flushing the appliance.
• To get the best results repeat above-mentioned step once or
twice.
• When finished, flush the appliance twice by repeating the
above-mentioned steps only use water instead.
DISASSEMBLY- AND RE-ASSEMBLY ADVISE