HD7824/50/B
3-5
REPAIR INSTRUCTION & PARTS LIST
Automatic filling procedure:
The Senseo PCB contains an automatic fi lling procedure
software routine.
This fi ll routine is only meant for
back-up
.
Normally the consumer has to follow the guidelines stated in
the DFU.
The fi lling procedure functions as follows:
The consumer has to fi ll the water container and has to plug
the appliance on the mains.
When the Senseo main switch has been pushed the main
switch LED will light continuously. This is only the case
when the Senseo has not fi nished the fi lling procedure
completely! (
First use
)
When the consumer pushes the one or two-cup button, the
Senseo will start automatically the pump to fi ll the boiler.
When the boiler is fi lled the pump stops pumping. (Pump
time approximately 22 seconds)
When the fi lling procedure has been successful the software
will clear a
Boiler_empty_fl ag
in the Eeprom.
By means of this
Boiler_empty_fl ag
the system knows the
boiler is fi lled or not!
When the Senseo is switched off or disconnected from the
mains, the value of the
Boiler_empty_fl ag
is stored in the
Eeprom chip.
Restoring the Boiler_empty_flag to production default:
Some times it is needed that the boiler of the Senseo have to
be emptied.
This for instance in wintertime where the possibility exists
that the boiler becomes frozen during transport e.g.
For those occasions it is handy to restore the
Boiler_empty_
fl ag
again to production default in the Eeprom.
Bringing the Senseo back into production status, has the
benefi t the fl ush routine will be activated automatically
when installed by the consumer, see topic
Automatic fi lling
procedure
.
To
SET
the
Boiler_empty_fl ag
can be done by:
Keep the 1-cup button pressed while plugging in the power
cord of the appliance.
The main switch LED will blink very rapidly for
approximately 1 second.
To check if the
Boiler_empty_fl ag
is really set, you should
reconnect the power cord a second time to the net and push
the main switch.
The main switch LED should light continuously.
Pos
Service code
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
4222 259 37060
4222 259 37070
4222 247 42550
4222 247 48190
4222 259 37920
4222 240 05940
4222 247 41860
4222 247 47970
4222 247 41950
4222 247 06810
4222 240 05990
4222 247 41920
4222 259 34970
4222 259 35440
4222 247 06840
4222 247 05130
4222 259 35500
4222 259 36500
4222 247 45890
4222 247 45780
4222 247 05180
4222 247 35870
4222 247 39890
4222 247 05110
4213 247 05250
Padholder 1 cup
Soft grey Soft grip
Padholder 2 cup
Soft grey Soft grip
Collector Black
Spout cover
Soft grey
Spout assy
Silver grey
Driptray cover
Driptray Black
Lever Soft
grey
Pushrod
Sealing ring
Ejector pin
Distribution disk
Black
3-Way valve
Boiler assy
V7.0 - 230 V
Hose
O-ring (NTC)
NTC assy
Water tank assy TOP
Soft grey
Valve outlet
Soft grey
Back cover
Soft grey
WC sealing
Filter
WC socket hard
Corrugated tube
Foot