background image

HD7824/50/B

3-5

REPAIR INSTRUCTION & PARTS LIST

Automatic filling procedure:

The Senseo PCB contains an automatic fi lling procedure 
software routine.
This fi ll routine is only meant for 

back-up

.

Normally the consumer has to follow the guidelines stated in 
the DFU.
The fi lling procedure functions as follows:
The consumer has to fi ll the water container and has to plug 
the appliance on the mains.
When the Senseo main switch has been pushed the main 
switch LED will light continuously.  This is only the case 
when the Senseo has not fi nished the fi lling procedure 
completely! (

First use

)

When the consumer pushes the one or two-cup button, the 
Senseo will start automatically the pump to fi ll the boiler.
When the boiler is fi lled the pump stops pumping.  (Pump 
time approximately 22 seconds)
When the fi lling procedure has been successful the software 
will clear a 

Boiler_empty_fl ag

 in the Eeprom.

By means of this 

Boiler_empty_fl ag

 the system knows the 

boiler is fi lled or not!

When the Senseo is switched off or disconnected from the 
mains, the value of the 

Boiler_empty_fl ag

 is stored in the 

Eeprom chip.

Restoring the Boiler_empty_flag to production default:

Some times it is needed that the boiler of the Senseo have to 
be emptied.
This for instance in wintertime where the possibility exists 
that the boiler becomes frozen during transport e.g.
For those occasions it is handy to restore the 

Boiler_empty_

fl ag

 again to production default in the Eeprom.

Bringing the Senseo back into production status, has the 
benefi t the fl ush routine will be activated automatically 
when installed by the consumer, see topic 

Automatic fi lling 

procedure

.

To 

SET

 the 

Boiler_empty_fl ag

 can be done by: 

Keep the 1-cup button pressed while plugging in the power 
cord of the appliance.

The main switch LED will blink very rapidly for 
approximately 1 second.

To check if the 

Boiler_empty_fl ag

 is really set, you should 

reconnect the power cord a second time to the net and push 
the main switch.
The main switch LED should light continuously.

Pos

Service code

Description

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

4222 259 37060
4222 259 37070
4222 247 42550
4222 247 48190
4222 259 37920
4222 240 05940
4222 247 41860
4222 247 47970
4222 247 41950
4222 247 06810
4222 240 05990
4222 247 41920
4222 259 34970
4222 259 35440
4222 247 06840
4222 247 05130
4222 259 35500
4222 259 36500
4222 247 45890
4222 247 45780
4222 247 05180
4222 247 35870
4222 247 39890
4222 247 05110
4213 247 05250

Padholder 1 cup 

Soft grey Soft grip

Padholder 2 cup 

Soft grey Soft grip

Collector Black
Spout cover 

Soft grey

Spout assy 

Silver grey

Driptray cover
Driptray Black
Lever Soft 

grey

Pushrod
Sealing ring
Ejector pin
Distribution disk 

Black

3-Way valve
Boiler assy 

V7.0 - 230 V

Hose
O-ring (NTC)
NTC assy
Water tank assy TOP 

Soft grey

Valve outlet 

Soft grey

Back cover 

Soft grey

WC sealing
Filter
WC socket hard
Corrugated tube
Foot