HD7811/94
REPAIR INSTRUCTION
Restoring the Boiler_empty_fl ag to production default:
Some times it is needed that the boiler of the Senseo have to
be emptied.
This for instance in wintertime were the possibility exists that
the boiler becomes frozen during transport e.g.
For those occasions it is handy to restore the
Boiler_empty_
fl ag
again to production default.
Bringing the Senseo back into production status, has the
benefi t the fl ush routine will be activated automatically
when installed by the consumer, see topic
Automatic fi lling
procedure
.
To
SET
the
Boiler_empty_fl ag
can be done by:
Keep the 1-cup button pressed while plugging in the power
cord of the appliance
.
The main switch LED will blink very rapidly for
approximately 1 second.
To check if the
Boiler_empty_fl ag
is really set, you should
reconnect the power cord a second time to the net and push
the main switch.
The main switch LED should light continuously.
4-6
PARTS LIST
Pos
Service code
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
4222 259 48531
4222 259 48731
4222 259 48741
4222 247 39540
4222 247 37140
4222 240 06670
4222 247 35790
4222 247 35820
4222 240 06400
4222 247 06810
4222 259 06890
4222 259 34970
4222 259 44281
4222 247 06511
4222 259 35569
4222 247 05130
4222 259 35500
4222 259 48661
4222 259 20100
4222 247 37200
4222 259 36953
4222 259 37384
4213 247 05250
4222 259 48521
4222 247 39902
4222 247 39913
4222 247 39941
Brew chamber assy (Brazil)
Deep Red
Padholder 1-cup (Brazil)
Black
Padholder 2-cup (Brazil)
Black
Foam chamber
Foam chamber cover
Black
Drip tray cover
Drip tray
Push rod
Slider spring
Brew chamber radial seal
Distrubutor assy
3-Way valve assy
Boiler assy TCO
V7.0 - 120 V
Pressure hose
Base PCB assy basic
1)
120
V
O-ring (NTC)
NTC assy
Water tank assy (Brazil)
Soft grey
XL(10 Cups) Water tank assy
Silent blue
Valve outlet
Raven black
Back cover assy
Raven black
Pump
ULKA HF 120 V ~60 Hz
Foot
Front Cover
Deep Red
Button Frame
Silver
On/Off button
Button Cover
Silver
1)
When you replace the PCB the coffee volume has to be re-set to your country specific setting.
Please carry out the Volume Adjustment Procedure to align the volume to your local specification
(see table).