background image

10

HD7806/50 /51 /52 /59

Adjusting the scale factor for the strong/short 
(60 ml) cup volume.

13. Remove the 

water tank

 from the machine. (for 

adjusting the right parameter, the internal 

SW

 

will check if 

the water level sensor

 is 

activated

 

yes/no)

14. Press the 1- and 2 cup button simultaneously 

and plug the mains on.

15. Release the 1- and 2 cup button, if successful, 

the on/off LED will switch on less bright/
intense as normal, indicating the scale factor 
reprogramming has entered.

16. Depending if the volume has to de- or increase 

you have to push the one- or two-cup button. 
Every time you push the 1- or 2-cup button, 
the LED will turn off for 0.5 second (feedback 
to user) and the scale factor will be shortened 
or lengthened depending which button was 
pushed. 

Pushing 1-cup button

, scale factor will be 

shorten

 approximately   - 1 cc/ml (less coffee) 

Pushing 2-cup button

, scale factor will be 

lengthen

 approxi 1 cc/mL (more 

coffee) 
The new value will be stored when you switch 
the appliance off by pushing the main switch. 
(LED will turn off)

17. Turn appliance on again and brew one strong 

coffee cup by pressing the 1-cup button twice, 
measure the volume. In case the volume is not 
within specification repeat steps 13 – 17.

18. End

Example table, switching from WEU to French/
Spain specification or vice versa, you need to 
execute below:

Restoring the Boiler_empty flag to production 
default:

Sometimes it is needed, that the boiler of the 
SENSEO have to be emptied.

This for instance in wintertime were the possibility 
exists that the boiler becomes frozen during 
transport e.g.

For those occasions, it is handy to restore the 

Boiler_empty_flag

 again to production default.

Bringing the SENSEO back into production status, 
has the benefit the flush routine will be activated 
automatically when installed by the consumer, see 
topic 

Automatic filling procedure

.

How to 

SET

 the 

Boiler_empty_flag

:

Keep the 1-cup button pressed while plugging 
in the power plug of the appliance in the mains 
socket

.

The main switch LED will blink very rapidly for 
approximately 1 second.

To check if the 

Boiler_empty_flag

 is really set, 

reconnect the power plug to the mains a second 
time and push the main switch. The main switch 
LED should light continuously.

Change volume setting

Adjusting normal/smooth 1-cup volume 

step 6- 12

Adjusting short/strong 1-cup volume 

step 13 - 17

WEU => French/Spain

Push 7x  1-cups with water in tank

16x  2cups without tank

French/Spain => WEU

Push 7x  2-cups with water in tank

16x  1cups without tank

Functions/features explanation

Summary of Contents for Senseo HD7806/50

Page 1: ...in d un conseil Une question sur ce produit RDV sur la communauté SAV Darty https sav darty com Déjà 1 2 million de solutions grâce à l avis des utilisateurs PHILIPS CAFETIERE HD7806 51 MANUEL D UTILISATION ...

Page 2: ...Service Manual Senseo Original HD7806 50 HD7806 52 HD7806 51 HD7806 59 ...

Page 3: ...product is void if you do not use genuine Philips spare parts to repair critical components of your appliance The critical components are indicated with a warning triangle in the service exploded view and or service manual HD7806 50 51 52 59 Contents General information 3 Technical information Consumer Replaceable Parts Optional accessories Technical information 4 Materials Production date or seri...

Page 4: ...0 C 10 KΩ 0 4 KΩ T 100 C 0 8 KΩ 0 02 KΩ Consumer Replaceable Parts HD5009 01 Podholder 1 cup Black HD5010 01 Podholder 2 cup Black HD5011 01 Water container Sepia grey CP0216 01 Water container Translucent specific models CP0220 01 XL Water container Sepia grey only for HD6555 CP0217 01 Driptray cover Black CRP116 01 Driptray cover Metal only for HD6556 CRP117 01 Driptray CP0602 01 Spout CP0603 01...

Page 5: ... normal cup 122 ml 133 10 266 10 French Spanish version normal cup 100 ml 109 20 218 20 All countries short cup 60 ml 71 10 142 10 Difference between left right volume 10 ml 10 ml Measure equipment needed Thermometer with K sensor 0 100 C 2 C Plastic cup Scale balance 0 300 g 2 g Materials Housing PP Housing ABS only for HD6556 Water container PP Brew chamber PA Spout POM Hoses Silicon Drip tray D...

Page 6: ...5 Functional diagram Boiler Pump 3 way valve Brew head Water Container Electical diagram CONTROL PCB L N Boiler Pump M Push buttons TCO Fuse Fuse Temp Sensor Water level Sensor Technical information ...

Page 7: ... the positions see picture 1 and lift the cover over the snap locks on both positions The cover lid can now be lifted up a little and to remove the complete cover including lever and push rod squeeze strongly with two fingers both legs of the push rod see picture 2 to each other so that the two pins will get out of the hinge position on the brew chamber To remove lever from lid cover take a screwd...

Page 8: ...ew chamber comes loose Reassemble follow above steps backwards To reach the components placed on the base handle as follows First remove back cover brew chamber and 3 way valve Remove both Torx T15 screws see exploded view in the near of position A Bend the 2 click snap locks with a screwdriver see base and the housing can now be removed To remove the rest of the housing unlock the last 4 snap loc...

Page 9: ...hort coffee Press the 1 cup button once for one large mild cup of coffee Select the strong short coffee recipe by double tap on the 2 cups button for a double cup of strong short coffee Press the 2 cup button once for two large mild cups of coffee Selecting the right PCBA modus Enable Disable the Intensity select feature The PCBA is standard delivered with the Intensity select feature disabled thi...

Page 10: ...he appliance has finished you are able to perform the volume adjustment Adjusting the normal 1 cup volume WEU or French Spain 6 Empty the cup podholder and push again for one cup setting measure the volume output with a graduated beaker In the table above you can find the requirements for the minimum maximum water volume output cc ml values 7 Unplug the appliance from the mains 8 Make sure the wat...

Page 11: ...olume is not within specification repeat steps 13 17 18 End Example table switching from WEU to French Spain specification or vice versa you need to execute below Restoring the Boiler_empty flag to production default Sometimes it is needed that the boiler of the SENSEO have to be emptied This for instance in wintertime were the possibility exists that the boiler becomes frozen during transport e g...

Page 12: ...pliance according instruction for use Boiler NTC defect Exchange boiler NTC Too less coffee Podholder blocked Descale podholder or exchange Boiler full of scale Descale appliance according instructions for use 3 way valve defect Exchange 3 way valve None of the above Adjust the SW in the PCBA Too less coffee 1st cup Pump backflow Exchange pump Too much coffee Bypass podholder Exchange podholder Tr...

Page 13: ... holder assy 1 cup Black HD5009 01 3 4222 259 62791 Pad holder assy 2 cup Black HD5010 01 4 4222 247 77141 Spout cover Black CP0603 01 5 4222 247 77132 Spout Black CP0602 01 6 4222 247 66481 Drip tray cover Black CP0217 01 7 4222 247 72531 Drip tray CRP117 01 8 4222 247 77601 Front cover printed Mystic blue 9 4222 247 77621 Housing Mystic blue 101 Torx T15 screw Service parts ...

Page 14: ...rts Pos Service code Description Remark 10 Brew chamber lid 11 Lever 12 4222 247 72881 Pushrod 13 4222 240 06911 Slider spring 14 4222 247 35837 Slider 15 4222 247 07461 Brew chamber seal 16 4222 259 67752 Distributor assy Coffee boost ...

Page 15: ...2 59 Service parts Pos Service code Description Remark Online CRP 30 4222 247 39963 Sensor housing 31 4222 259 48666 Water container Sepia Grey HD5011 01 32 4222 247 40983 Valve outlet Black 33 4222 259 60151 Back cover assy Black ...

Page 16: ...emark 17 4222 259 59541 3 way valve 18 4222 259 65482 Boiler assy OPR 230 V 19 4222 247 75271 TCO cap for OPR boiler 20 4222 24743694 Boiler pin cap 21 4222 247 72551 Suspension bracket 22 4222 247 06511 Pressure hose 28 4222 247 05136 O ring NTC 29 4222 259 39373 NTC assy ...

Page 17: ...3 4222 259 68452 PCB assy OPR Intensity select 230 V 24 4222 259 68401 Button frame printed Black 26 4222 259 63422 On off button printed 27 3000 016 66541 Base plate Black 34 4222 259 37248 Pump 230 V 50 Hz 35 4222 247 05191 Pump damper 36 4213 247 05256 Foot 100 4222 244 50684 Tie wrap Not shown ...