THANK  YOU  FOR  PURCHASING  A  PHILIPS  SELECON  PLCYC2  LED  LUMINAIRE.  
WE  HAVE  DESIGNED  THIS  LUMINAIRE  TO  PROVIDE  YOU  WITH  A  SUPERIOR 
FITTING  IN PERFORMANCE, DESIGN  AND  ENGINEERING.  WE ARE CONFIDENT 
THAT IT WILL PERFORM TO YOUR EXPECTATIONS FOR MANY YEARS TO COME. 

Caution! 

Installation is entirely at your risk.  Do not attempt installation unless you are suitably qualified.  If you do 

not understand a point in this manual, don’t guess.  Don’t take short cuts.  If in doubt, stop!  Contact Philips Selecon 
or one of its authorised distributors for advice.  Don’t be afraid to ask for help. 

 
This SHORT FORM MANUAL is designed to provide you with the information that you will need IMMEDIATELY upon 
unpacking your new luminaire.  This manual covers information required for PLCYC2-03 products. 

We recommend making a note of the serial numbers of your purchased luminaires for future reference. 

(The serial number can be found on the sticker on the side of the yoke on the unit and on the outside of the box the unit was packed in).

 

 

Important Note

:  Before discarding the packaging ensure you have the suspension bolt set 

 

Electrical Installation 

WARNING!!!

  Risk of fire and electric shock.   This product is to be installed by  a qualified electrician only.   Ensure  that the AC 

power is switched off before attempting to make any wiring connections.   
This fixture employs a grounded type receptacle and is not intended for connection to a two-wire, ungrounded source of supply. 
To  avoid  the  chance  of  product  damage  or  malfunction,  disconnect  power  before  connecting  wires,  and  do  not  connect  or 
disconnect cables (supply, data, lamps and interface cables) when voltage is supplied to the luminaire. 
 

Mains Voltage:

 100-240VAC (+/- 10%). 

unit must be direct switching mains only, not via a dimmer system.

 

When installing this fixture use wire conductor colour codes as follows:  

 

 

 

 

Brown   

- Phase, live 

 

 

 

 

Blue 

 

- Neutral, return 

 

 

 

 

Green/Yellow 

- Earth, ground 

 
PLCYC2  luminaires  can  be  linke

d  together  in  a  ‘daisy  chain’  fashion,  using  a  Powercon  interconnect  cable.    The  MAXIMUM 

number of luminaires which can be linked together on one circuit is limited by the 

Input Voltage

, the Maximum power supply limit 

of 

300W

 and the Maximum Allowable input current of 

20A

.  So on a circuit capable of supplying the maximum 20A and: 

 
 

on a 

100V supply, a maximum of 6 units

 can be used 

 

on a 

240V supply, a maximum of 16 units

 can be used 

REFER TO FULL MANUAL FOR MORE DETAILS 

 

Mounting 

A safety bond MUST always be used when rigging luminaires on bars, trusses, etc.  The safety bond is fixed to the luminaire 
lamp-house anchor point, located at the top of the luminaire, and is wrapped around the bar and attached to itself.  This is the 
only recommended anchor point for the luminaire.  Philips Selecon supplies a fitted safety bond with all theatrical / entertainment 
luminaires. 
 
The PLCYC range has been designed to meet demanding quality 
light level applications 

– multiple luminaires are required to obtain 

a  visually  even  wash  of  light.    Recommended  spacing  of 
luminaires is to have a ratio of 5:4 (spacing apart : distance from 
the  wall).  For  example if the luminaires  are  1.5m away from the 
wall  the  optimum  spacing  between  the  luminaires  for  an  even 
wash of light would be 1.2m. 

For optimum light distribution the PLCYC2 has been designed to be installed at a 45deg 
nominal angle as indicated. 
 
 
 
 
 
 
Ambient Operating Temperature: 

0°C to 40°C 

To  guarantee  product  lifetime,  the  user  should  ensure  that  the  ambient  temperature 
remains within the recommended temperature range. 

 

 

Philips Selecon has packaged this product using environmentally friendly packaging. Please consider 
either reuse of the packaging or dispose of responsibly with your nearest recycling collection agency.

Adjusting the tilt angle 

Loosen the lock off handle on each side of the 
luminaire, tilt and retighten finger tight 

Summary of Contents for Selecon PLCYC2

Page 1: ... When installing this fixture use wire conductor colour codes as follows Brown Phase live Blue Neutral return Green Yellow Earth ground PLCYC2 luminaires can be linked together in a daisy chain fashion using a Powercon interconnect cable The MAXIMUM number of luminaires which can be linked together on one circuit is limited by the Input Voltage the Maximum power supply limit of 300W and the Maximu...

Page 2: ...lows the customisation of current intensity light output Note using the LEFT and RIGHT arrow buttons you can select each RGBW channel individually and using the UP and DOWN arrows change their intensity OK Enter Button Accesses details activates a field or enters a setting depending on the current menu item Up Down Left Right Arrow Buttons Navigates menu system and used for selecting and setting o...

Page 3: ...3 of 4 MAIN MENU CONTINUED Settings available for editing are dependent on the current security level These include General Presets DMX Fan and Display Unwanted changes to a luminaire s settings can be locked see security on pg4 ...

Page 4: ...o prevent tampering A 4 digit password can be set for each of three different levels of security within the settings menu when in security level 3 The fixture can be locked by scrolling to Lock Fixture in the menu and choosing Yes when asked if you want to lock the fixture To unlock the fixture the chosen password will be required Service and Maintenance Philips Selecon has manufactured this lumin...

Reviews: