Connecting to the DMX512 Network
7
PLCYC1 MKII LED Luminaire
Installation & User’s Manual
If the unit is supplied with an AC input cable but you did not order an AC input connector, Table 1 describes how to
connect power to your PLCYC1 MKII LED Luminaire. Field wiring of the PLCYC1 MKII LED Luminaire is
straight forward. A total of 3 wires/conductors need to be brought to the unit. The following wiring scheme is
required:
Table 1:
PLCYC1 MKII LED Luminaire AC Input
Connections
3. Connecting to the DMX512 Network
Basic DMX512 installation consists of connecting multiple PLCYC1 MKII LED Luminaires together (up to 30
luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX
connector on the first PLCYC1 MKII LED Luminaire. Another cable runs from the other DMX connector on the first
unit to a DMX connector on the next PLCYC1 MKII LED Luminaire (or DMX512 device to be controlled).
Note:
For more information on DMX512 networking and systems, refer to
"Additional Resources for DMX512" on
page 1
. For PLCYC1 MKII LED Luminaire DMX Mapping, refer to
"DMX CONTROL" on page 16
.
Figure 4: PLCYC1 MKII LED Luminaire - DMX512 Connections
Wire Color
Purpose
Brown
Main / Line (120 to 240VAC)
Blue
Neutral
Green/Yellow
Ground
Neutral
Main /
Ground / Earth
Line
AC Input Connector
(on back of unit)
DMX512
DMX512
(out from first
to second luminaire)
DMX512
(out to the next luminaire or DMX512
controlled device)
PLCYC1 MKII LED Luminaires
(from console or
control device)
DMX512 Connections
Data Thru
Cable Pinout
Male Conn
Pin 1
Common
(Drain)
Pin 2
Data (-)
Pin 3
Data (+)
Pin 4
Not Used
Pin 5
Not Used
Data In
Cable Pinout
Female Conn
1
2
3
4
5
1
2
3
4
5