4-1
Spindle motor does not move
Yes
Yes
No
No
No
No
Yes
Check whether “AVCC”
(+5V) voltage is normal.
Correct connection
Check the AVCC power
supply
Check/Replace Q8
、
Q9.
Check/ Replace U3.
Have no to focus
1. Check U3 42pin FOO signals
2.If there are F+, F-, T+ and T-
signals output from U2.
Check/Replace the loader
Yes
Yes
No
Go
Check whether laser voltage
(2V for VCD & 2.2V for DVD)
on Collector of Q8 and Q9
Check the FFC connection
between 24P and the loader.
1.Whether voltage on pin 44 of U3
varies between 0 and 3.3V (3.3V for
VCD and 0V for DVD),
2.Whether peripheral components
are eroded or badly soldered.
Trouble shooting chart
Motor no move
Summary of Contents for SDV434/19
Page 23: ...Service Engineer Remarks 6 2 ...
Page 25: ...6 4 6 4 Front Board Top Side Front Board Bottom side ...
Page 29: ...7 3 7 3 Power Board Top Side ...
Page 36: ...8 6 8 6 Mpeg Board Top Side ...
Page 37: ...8 7 8 7 Mpeg Board Bottom Side ...
Page 42: ...Mechanical Exploded view 9 1 ...
Page 44: ...REVISION LIST Version 1 0 Initial release 10 1 ...