Important safeguards
READ ALL INSTRUCTIONS BEFORE USING YOUR PHILIPS AVENT TWIN ELECTRONIC
BREAST PUMP
When using electrical products, especially when children are present, basic safety
precautions should always be followed, including the following.
WARNING
– To reduce the risk of fire, electrocution or other
personal injury:
• Always unplug from the electrical wall socket immediately after use.
• Do not use while bathing.
• Do not place or store the product where it can fall or be pulled into a bath or sink.
• Do not place or drop the pump motor, control handle, electric adaptor or wall plug lead
into water or other liquids.
• Do not reach for a product that has fallen into water. Unplug from the electrical
wall socket immediately.
• Do not allow children or pets to play with the pump motor, tubing, power supply or
accessories as these parts may pose a choking or strangulation danger.
• Before each use inspect the product, including mains power lead, for signs of damage. Never operate this product
if it has a damaged lead or plug, if it is not working properly, if it has been dropped or damaged, or has been
submerged in water.
• Only use attachments recommended by Philips AVENT.
• Do not use outdoors with the wall plug lead or where aerosol spray products are being used, or where oxygen
is being administered.
• Equipment not suitable for use in the presence of flammable anaesthetic mixture with air, or with oxygen or
nitrous oxide.
• Only use the electric adaptor supplied with the product.
• Ensure the unit is not exposed to extreme heat or placed in direct sunlight.
• There are no user serviceable parts inside the breast pump. Do not attempt to open, service or repair the
breast pump yourself.
• Keep leads away from heated surfaces.
• The parts of the pump which come directly into contact with milk are personal care items and should not be
shared between mothers. The only parts which can be shared are the pump motor, the control handle, the tubing
and the double pumping connector.
• Do not attempt to remove the pump body from the breast while under vacuum. Turn the unit off and break the seal
between your breast and the pump funnel with your finger, then remove the pump from your breast.
• Never use while pregnant as pumping can induce labour.
• Never use when sleepy or drowsy.
• This appliance is intended for use by responsible persons, keep out of reach of small children and the infirm.
• This appliance is not intended for use by persons including children with reduced physical, sensory or mental capabilities,
or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
CAUTION
– To reduce the risks of injury, device malfunction or failure:
• The product should not be left unattended when plugged into an electrical wall socket.
• Never drop or insert any foreign object into any opening or tubing.
• Do not shorten the tubing.
• Make sure the voltage of the electrical adaptor is compatible with the power source.
• Plug the electric adaptor into the pump motor first, then securely attach the wall plug lead
into the electric adaptor. Lastly, insert the plug into electrical wall socket.
• Although compliant with applicable EMC directives, this equipment may still be susceptible
to excessive emissions and/or may interfere with more sensitive material.
• Wash, rinse and sterilise the appropriate pump parts before each use.
• Do not continue pumping for more than five minutes at a time if no result is achieved.
• Do not use antibacterial or abrasive cleaners/detergents when cleaning breast pump parts.
• Never put the control handle or breast pump motor in water or steriliser, as you can cause permanent damage
to the pump.
• If the pressure generated is uncomfortable or causing pain, turn the unit off, break the seal between
the breast and the pump body with your finger and remove the pump from your breast.
How to clean and sterilise
your pump
(see diagram A)
NEVER WASH OR STERILISE…
the control handle (a), twin
tubing (k), double pumping
connector (l) or pump motor (m).
These components DO NOT come
into contact with your breast milk
.
You can wipe the pump motor and control handle clean, using a soft cloth.
Cleaning and sterilising the pump bodies
Before you use your breast pump for the first time
and every time before use, you must disassemble,
wash and sterilise all the breast pump parts that
come into contact with your breast milk.
You can use the dishwasher (top rack only) or hand
wash in warm, soapy water and then rinse thoroughly.
Sterilise these parts in a steam steriliser (digital,
electric or microwave), or by boiling in water
for 5 minutes.
Do not use antibacterial or abrasive cleaners or
detergents as they may cause the plastic to crack.
To clean the valve, rub gently between your fingers
in warm soapy water – do not insert objects as this
may cause damage.
Keeping your pump sterile and
compact for travel
After sterilising all parts, insert the white valve and
diaphragm into the pump body (d) and clip the funnel
cover (h) over the Let-down Massage Cushion (g).
Now screw the sealing base (s) onto the pump body (d)
in place of the milk container.
k
a
m
d
g
s
h
l
9
10
Summary of Contents for SCF304/60
Page 7: ...H I 6 7 v 8 1 2 u w 6 ...
Page 21: ...20 ...
Page 22: ...21 ...
Page 23: ...22 ...
Page 24: ...23 ...
Page 25: ...24 ...
Page 26: ...25 ...
Page 27: ...26 ...
Page 28: ...27 ...
Page 29: ...28 ...
Page 30: ...29 30 l k a m d g s h ...
Page 31: ...30 ...
Page 32: ...31 a b c d e f g h i j k l m n o ...
Page 33: ...32 ...