background image

SC2001/00

FAQs - Project SC2001 - Philips Lumea

AFTER USE

45.  After using Philips Lumea IPL hair removal system, the hair follicle sheds hair naturally. Isn’t that messy?

 

- No.  Although the hair sheds naturally during the next couple of days after treatment, it will not fall out all at once.  You will 

not even notice this process . 

46.  Are there any side effects from using the appliance?

 

- The appearance of slight to moderate redness immediately after the treatment is both harmless and normal and will disappear 

quickly. 

 

- You may feel warmth, itching and a burning or tingling sensation during the treatment.  Again, this is normal and you will 

fi nd that the sensation disappears immediately after treatment.

 

- Longer-lasting skin reactions are not common so long as the appliance is used according to the instructions in the user 

manual.  Please read the user manual carefully and follow the instructions at all times.  We recommend that you also read the 

list of contraindications

 carefully.  Misuse of the appliance such as using it at a setting that is too high can be linked to skin 

reactions such as redness, burns and/or discoloration.  To prevent the occurrence of skin reactions reduce the intensity as soon 
as the sensation feels uncomfortable.

 

- If these reactions do not disappear within 3 days, we advise you to consult a doctor.  Wait until the skin has healed 

completely before treating again and be sure to use a lower light intensity.

 

- Skin discoloration may occur very rarely and will manifest as either a darker or lighter patch than that of the surrounding 

area.  This is the result of using a light intensity that is too high for your skin color.  If the discoloration does not disappear 
within 2 weeks, we advise you to consult a doctor.  Do not treat discolored areas until the discoloration has disappeared and 
skin has regained its normal color.

 

- Skin infection and infl ammation may occur very rarely and can be caused by using the appliance on wounds or cuts caused 

by shaving, on existing wounds or on ingrown hairs.

 

- Excessive pain can occasionally occur during or after treatment if you have used the appliance on unshaved skin, if you use 

the appliance at a light intensity that is too high for your skin color, if you fl ash the same area repeatedly or if you use the 
appliance on open wounds, infl ammations, infections, tattoos, burns, etc..

 

- Please read the 

user manual

, especially the contraindication list carefully and follow the instructions at all times.

47.  Why do skin reactions occur?

 

- The appliance uses light and light involves heat.  Slight redness of the skin after the treatment is a normal reaction to the heat 

of the light.

 

- Be careful when selecting the light intensity and follow the instructions listed in the user manual to determine the correct 

intensity for your skin type.  You may increase the risk of the occurrence of skin reactions like redness and/or discoloration if 
you select a too high intensity.

 

- If you treat one and the same area twice without lifting the appliance, you may increase the risk of skin reactions such as 

redness and/or discoloration.  It is in gentle enough to treat each area once with the overlap described in the Philips Lumea 

user manual

.

 

- If the removable window, the metallic surface inside the removable window and/or the light exit window with fi lter glass is 

not cleaned properly, you may increase the risk of the occurrence of skin reactions like redness, burning or discoloration.

 

- All types of tanning - exposure to natural sunlight as well as artifi cial tanning methods such as tanning lotions, tanning 

appliances etc. - may cause skin reactions after the treatment with Philips Lumea.  Perform a skin test on the area you intend 
to treat in order to determine the appropriate light intensity for you.

48.  What can I do to prevent skin reactions?

 

- Choose a lower intensity the next time.  Do not use an intensity that you fi nd uncomfortable. 

 

- Check the 

list of contraindications

 to see if any of those listed applies to you.  If a skin reaction lasts longer than 3 days, 

consult your doctor. 

 

- Keep the removable window and the light exit window clean at all times.

 

- To avoid longer-lasting redness, cool the skin with cloth which has been dipped in cold water. 

 

- Never treat the same area twice without lifting the appliance (see instruction in 

user manual

). 

 

- Select the intensity for the treatment areas very carefully.  Do not use an intensity - however high or low - that you fi nd 

uncomfortable.

 

- If the treatment becomes too painful at any time, reduce the light intensity setting until the treatment becomes comfortable 

again.  If you notice skin reactions stronger than slight redness, stop using the appliance immediately.

49.  Do I have to take any precautions after the treatment?

 

- For 48 hours after treatment, avoid intensive sunbathing without proper skin protection (sun blocker) and do not apply 

cosmetic products. 

 

- If you feel warm in the areas treated for a long time after the treatment is over, you may wish to cool your skin with cloth 

dipped in cold water.  Use a lower intensity the next time. 

8-12

Summary of Contents for SC2000

Page 1: ...as officially laid down at this moment TECHNICAL INFORMATION Rated voltage 100 V 240 V Rated frequency 50 Hz 60 Hz Rated input 7 5 W Protection against electric shock Class II Q Protection rating IP 30 EN 60529 Operating conditions Temperature 15 C to 35 C Relative humidity 25 to 75 Storage conditions Temperature 0 C to 60 C Relative humidity 5 to 95 Intense pulsed light lamp Spectrum 570 nm Lithi...

Page 2: ...001 00 EXPLODEDVIEW PARTS LIST 2 3 1 Pos Service code Description 1 2 3 4203 035 86860 4203 035 86870 4203 035 60221 4203 035 60231 Recessed window Assy Pouch Adapter W Eu Adapter GB not shown 2 12 changed ...

Page 3: ...specifically designed for facial hair removal 6 Can this method be used for a full bikini area depilation including sensitive areas Yes Philips Lumea is safe and gentle enough for use on the entire bikini area e g for Brazilian or Hollywood styles On darker more sensitive pigmented areas of the bikini area use a lower setting Do not use in mucous areas vagina and anus 7 Can men use the Philips Lum...

Page 4: ...changed to continuous orange the battery will still contain enough energy for at least 30 flashes This means that you still have enough flashes to treat one underarm or one side of the bikini line before putting the device on charge TREATMENT INTERVAL 20 How often should I use Lumea IPL hair removal solution We recommend that you use the appliance once every two weeks on armpit and bikini area to ...

Page 5: ...ndow can become contaminated with stray hairs and dirt A contaminated removable window will reduce the lifetime and efficacy of the appliance Additionally burns black spots on the removable window may cause treatment to become painful or result in skin reactions such as redness and discoloration You can stop shaving when all the hairs have stopped regrowing usually after approximately five treatme...

Page 6: ...the appliance by switching it off and on again 33 Is it normal that the appliance becomes warm during use Yes it is normal that the appliance becomes warm when used for longer periods of time 34 Why does the appliance switch off completely when I am using it The battery pack may be empty Check to ensure that batteries have been fitted 35 What parts of the appliance can be replaced The adapter the ...

Page 7: ...re intense than before You may be using it at a higher intensity than what you were using it at in earlier treatment sessions Check if the filter glass in the light exit window is broken If so please do not use the appliance anymore Check if you have shaved the treatment area properly and if the areas you are treating are free from oily substances like creams and lotions and water Check if your sk...

Page 8: ...y and follow the instructions at all times 47 Why do skin reactions occur The appliance uses light and light involves heat Slight redness of the skin after the treatment is a normal reaction to the heat of the light Be careful when selecting the light intensity and follow the instructions listed in the user manual to determine the correct intensity for your skin type You may increase the risk of t...

Page 9: ...ips Lumea IPL hair removal system It is normal for some hairs to still be visible after the first few treatments If you have used Philips Lumea more than 5 times but hairs are still visible it is possible that you may have selected an intensity lower than the one recommended for your skin and hair type Try a higher setting and use it ONLY if it is not uncomfortable to use Check if you have used th...

Page 10: ...sk of skin reactions Start by using the lowest recommended intensity according to the skin and hair type table Increase the intensity ensuring it is not inconvenient or painful Pain is linked to skin reactions such as burning redness and discoloration If the application starts to become painful at anytime reduce the intensity to the point that at which it is no longer uncomfortable Different areas...

Page 11: ... the hair to go into the resting phase The hair now sheds naturally and the hair growth is inhibited Hairs can take one or two weeks to shed Optimal hair removal cannot be obtained with a single session since only hairs in the anagen phase are susceptible to treatment with light During a treatment hairs on the treated areas are usually in different stages of the cycle of hair growh Ad MISCELLANEOU...

Page 12: ...oth available in professional salons for hair removal and as at home hair removal solutions Professional salons in general use light intensities at a much higher energy level which makes hair removal results last longer However removing 100 of hairs permanently with laser or IPL is highly unlikely even in professional salon treatments Permanent hair reduction as defined by the FDA Food and Drug Au...

Reviews: