background image

Summary of Contents for PM5324

Page 1: ... HFGenerator 100kHz 110MHz PM5324 9452 053 240 l 9499 450 05411 73050l l Ol ...

Page 2: ...PHILIPS Operating manual HFGenerator 100 kHz 110MHz PM5324 9452 053 240 1 9499 450 CJS4l l 730501 l 01 ...

Page 3: ...n correspondence concerning this instrument please quote the type number and the serial number as given on the type plate at the rear of the instrument N V PHILIPS GLOEILAMPENFABBIEKEN EINDHOVEN THE NETHERLANDS 1973 ...

Page 4: ...AM 8 2 DIRECTIONS FOR USE 10 2 1 INSTALLATION 10 2 1 1 Position 10 2 1 2 Connection to the mains 10 2 1 3 Earthing 10 2 2 OPERATION 11 2 2 1 Switching on I l 2 2 2 Adjusting the frequency 11 2 2 3 Adjusting the mode 11 2 2 4 Application 11 2 2 4 1 Unmodulated HF signal generator 2 2 4 2 Amplitude modulated AM HF signalgenerator i 2 2 4 3 Frequency modulated FM HF signalgenerator 13 2 2 4 4 Wobble ...

Page 5: ... easv to read linear scale The range which is in use and the scale to be read is indicated by means of LEDs The output voltage is electronically stabilised and is continuously adjustable The AM FM Generator may also be used in the frequency range from 150 MHz to 220 MHz e g in band Ill as a test generator for television sets or as a generator in the frequency range for taxi transmission With an in...

Page 6: ...lluminated scales 1 5 in the ranges 0 1 80 MHz 1 in range 75 110 MHz 0 5 in range 0 4 0 5 MHz 0 2 in range 10 3 11 l MHz 0 1 on calibrated points 0 1 at nominal operating conditions mains voltage variations 10 15 measured over 7 hours Temperature coefficient 5 2 10 4 oc Output HF OUT Frequencv respor se Connection BNC connector Output voltage 50 mV into 75 L at unmodulated signal O lMHz 110 MHz 3c...

Page 7: ...d 97 MHz dependent on frequency 20 Hz 60 kHz 10 kn 3 dB Band width Input impedance Wobbulating sweep 2tif range 0 4 MHz 0 5 MHz 0 40 kHz at 450 kHz range 10 3 MHz 11 3 MHz 0 600 kHz at rn 7 MHz Wobble frequency 25 Hz sawtooth BNC connector combined with sweep output Voltage 2 V Frequency 1 kHz sine wave Impedance 1 kD BNC connector combined with 1 kHz output Voltage 10 Vp p Frequency 25 Hz saw too...

Page 8: ...e 1 2 6 MECHANICAL DATA Dimensions Weight 1 3 Accessories 1 3 1 INCLUDED AS STANDARD Mains cable Directions for use 1 3 2 OPTIONAL Coax cable BNc 2 x 4 mm PM 9072 Coax cable BNC BNC 75 nPM 9075 Impedance transformer PM 9537 7 25 c 5 c 40 c 40 c 70 c Height 192 mm Width 287 mm Depth 290 mm 5 kg ...

Page 9: ...er the signals of the HF output stage and of the calibration oscillator are mixed The low frequency signal which is obtained at approximately equal frequencies of both signals is amplified limited rectified and indicated by a moving coil meter If the HF frequency control is set at a calibration frequency the indicator at exactly equal frequencies indicates a sharp limited minimum between two tull ...

Page 10: ...ECIMAL LIMITER I I I I SCALE I I DIVIDER RECTIFIER I I I I I I I I I I I l I I I AMPLITUD I I F REOUENCV MODULATOR HF OUTPUT HF i o IJLATOR BLANKING AMPLWIER ATTENUATOR 0U1 GATE i i I 1kHz J SWEEP 1 __ 3 __ our f _ 1 r I I LI J WEEPSIGNAl I IB v FM EXT lkHz1 kHz BLANKING _17 v OWER 1 I GENERATOR PULSE SUPPLV I i iIN lF GENERATOR OV y IN l I A M EXT 1 kH z t 1 I j I I I _j L 1 I I I I I l EEPWIDTH ...

Page 11: ...ch is in the inside of side plate Change the mains voltage indication plate at the rear Refit the handle bar Connect up the instrument 2 1 3 EARTHING The instrument must be earthed in accordance with the local safety regulations The mains cable supplied is provided with an earth core which is connected to the earth contacts of the mains plug If the instrument is connected to a mains socket with ea...

Page 12: ...e depressed at a time Button WOB may be unlocked by pressing the button a second time independently of the other buttons The mode buttons may be combined with the frequency range buttons according the table given below Range button Mode button selectable MHz CAL AM FM WOB 0 1 0 3 x x 0 3 _ 1 x x 3 x x 3 10 x x 10 30 x x 30 80 x x 75 110 x x x x 0 4 0 5 x x x 10 3 1 x x x x extra WOB AM x x x 2 2 4...

Page 13: ...12 Fig 4 Front view Fig 5 Rear view ...

Page 14: ...to sub para 2 2 4 5 Press button FM 1 kHz the HF signal is modulated in frequency by 1 kHz and a frequency sweep of about 25 kHz Apply the signal available at BNC connector HF OUT across a cable to the object to be measured Isse accessories chapter 1 3 Adjust the required output voltage by means of potentiometer HF AMPLITUDE Note When using harmonics the frequency sweep is multiplied by he order n...

Page 15: ...u Iating sweep 2 2 4 5 Calibration The calibration points are indicated on the scale by the symbol Y or A A moving coil meter which is illuminated at calibration mode serves as indicator Checking If a very accurate HF signal e g of 21 5 MHz is needed this can be checked as follows Switch on the instrument and wait at least 30 minutes for it to warm up Depress range button 10 30 MHz the diode along...

Page 16: ...851 853 13 2 5322 414 74021 Knob cover 14 2 5322414 74023 Knob 0 18 7 15 1 5322 455 74022 Textplate 16 1 53 2 276 14128 Mains switch 801 17 1 5322 276 64009 Push button switch 803 18 1 5322 450 84015 Pointer 19 1 5322 450 64041 Plexiglass window 20 4 5322 462 50101 Foot 21 4 5322 462 40157 Rubber stud 22 1 5322 492 6434 7 Spring 23 1 5322 265 30066 Mains input connector 854 24 1 5322 255 44064 Hea...

Page 17: ...arbon resistor C Wire wound resistor Kohleschlchtwiderstand Reihe E12 Drahtwlderstand Koolweerstand E12 reeks 0 S W 1 5MO 5 Draadgewonden weerstand lw n 10 Resistance au carbone st rie E12 1 SMn 10 Resistance boblnee 200 n 5 Resistencla de carb6n serle E12 Resistencla bobinada Wire wound resistor Drahtwidersund Draadgewonden weerstand Rbistance boblnee Resistencia bobinada 5 a Tubular ceramic capa...

Page 18: ... Metal film 667 5322 116 50897 18 2 k 1 MR25 Metal film 668 5322 116 50666 73 2 k 1 MR25 Metal film 669 5322 116 50446 66 5 k 1 MR25 Metal film Unit 2 601 5322 116 50524 3 k 2 CR25 Carbon 602 5322 116 54148 9 1 k 2 CR25 Carbon 603 5322 116 50859 91 k 2 CR25 Carbon 604 5322 116 54293 4 7 k 2 CR25 Carbon 605 5322 116 64147 3 9 k 2 CR25 Carbon 606 5322 116 54079 36 k 2 CR25 Carbon 607 5322 116 50872 ...

Page 19: ... 25 p 100 Ceramic 509 4822 122 31177 470 pF 2 100 Ceramic 510 4822 125 50045 2 22 pF 100 Trimmer 511 4822 122 31061 18 pF 2 100 Ceramic 512 4822 125 60045 2 22 pF 100 Trimmer 514 4822 125 60045 2 22 pF 100 Trimmer 515 4822 122 31061 18 pF 2 100 Ceramic 516 4822 125 60045 2 22 pF 100 Trimmer 518 4822 125 50017 5 5 65 pF 100 Trimmer 5 19 4822 122 31081 100 pF 2 100 Ceramic 520 4822 122 31056 12 pF 2...

Page 20: ...olyester 560 5322 122 10107 100 nF 20 80 30 Ceramic 561 4822 121 40232 220 nF 20 100 Polyester 562 5322 122 10107 100 nF 20 80 30 Ceramic 563 4822 122 31211 100 pF 5 400 Ceramic 564 5322 122 30103 22 nF 20 100 40 Ceramic 565 4822 124 20461 47 µF 10 Electrolytic 566 4822 122 31072 47 pF 2 100 Ceramic 567 4822 124 20463 100 µF 10 Electrolytic 568 5322 122 30103 22 nF 20 100 40 Ceramic Unit 2 501 532...

Page 21: ...2 134 44072 La 11p 40 mA 813 5322 134 44072 L amp 40 mA 815 5322 344 6404 Indicator 120 µA Ri 1500 i1 Semi conductors Diodes Type Ordering number Qty Location 88106 5322 130 30769 5 Unit 1 401 402 403 411 412 BAX13 632213040182 6 Unit 1 404 405 406 407 408 410 AA119 6322 30 40229 1 Unit 1 409 BA217 4822 130 30703 4 Unit 1 413 414 415 Unit 2 402 BA216 5322 130 30702 1 Unit 2 401 BZX79 C5V1 5322 130...

Page 22: ...ype Ordering number Oty Location FJH131 7400 5322 209 84 143 1 Unit 1 321 SN7490N 5322 209 84114 2 Unit 1 322 323 TAA310A 5322 209 84361 1 Unit 1 324 CA3086 5322 209 84111 1 Unit 2 321 SN72741P 5322 209 84163 2 Unit 2 322 323 ...

Page 23: ... Replacement 6 Cleaning and or lubrication 7 Operator error 8 Missing items on pre sale test 9 Environmental requirements are not met COMPONENT SEQUENCE NUMBER 1111111 Enter the identification as used in the circuit diagram e g GR1003 Diode GRI003 TS0023 Transistor TS23 ICOIOI RO co BO LA VL SK BU TO LO XO CB RE ME BA TR Integrated circuit ICIO Resistor potentiometer Capacitor variable capacitor T...

Reviews: