background image

16-Bit Mode

21

PLPROFILE1 MKII LED Luminaires

Installation & User’s Manual

DMX CONTROL

This section contains information for operating the luminaire using DMX control in 16-Bit, 8-Bit, or 3-Channel (3-
Chan) modes. For Menu options and detailed information, see 

"Settings" on page 19

.

Note:  

These tables assume a DMX start address of 1. When a different starting address is used, this address becomes 

channel 1 function and other functions follow in sequence.

1. 16-Bit Mode

Table 3 provides DMX channel mapping of all DMX512 control values when the PLPROFILE1 MKII LED 
Luminaire is in 16-bit DMX512 mode (as set by the luminaire’s menu system).

Table 3: 

PLPROFILE1 MKII LED Luminaire DMX Channel Mapping (16-Bit Mode)

DMX 

Channel

Parameter

Range DMX

Range%

Default 

recommended 

console default 

values

Description

1

Intensity - High

0 - 65535

0 - 100%

0

16-bit control for Intensity of LED settings.

2

Intensity - Low

3

Red - High Byte

0 - 65535

0 - 100%

0

16-bit control of Red LEDs from 0 to full.

4

Red - Low Byte

5

Green - High Byte

0 - 65535

0 - 100%

0

16-bit control of Green LEDs from 0 to full.

6

Green - Low Byte

7

Blue - High Byte

0 - 65535

0 - 100%

0

16-bit control of Blue LEDs from 0 to full.

8

Blue - Low Byte

9

White - High Byte

0 - 65535

0 - 100%

0

16-bit control of White LEDs from 0 to full.

10

White - Low Byte

11

Preset Color Selection

0 - 255

0 - 100%

0

Used to access presets stored in fixture 
firmware, such as CCT presets, defined gel 
presets, etc. 

No Preset Activated = DMX 0-3 

(default)

Color Preset 0 (Off) = DMX 4 - 7
Color Preset 1 (Scratch Pad) = DMX 8 - 11
Color Preset 2 (Warm White) = DMX 12 - 15
Color Preset 3 (Cool White) = DMX 16 - 19
Color Preset 4 (Daylight) = DMX 20 - 23
Color Preset 5 (Arc White) = DMX 24 - 27
Color Preset 6 (Red) = DMX 28 - 31
Color Preset 7 (Yellow) = DMX 32 - 35
Color Preset 8 (Daylight Blue) = DMX 36 - 39
Color Preset 9 (Magenta) = DMX 40 - 43
Color Preset 10 (Aqua) = DMX 44 - 47
Color Preset 11 (Medium Amber) = DMX 48 - 51
Color Preset 12 (Lavender) = DMX 52 - 55
Color Preset 13 (Blue) = DMX 56 - 59
Color Preset 14 (Light Pink) = DMX 60 - 63
Color Preset 15 (Green) = DMX 64 -67
Color Preset 16 (Pink) = DMX 68 - 71
Color Preset 17 (Amber White) = DMX 72 - 75
Color Preset 18 (Dark Fuchsia) = DMX 76 - 79
Color Preset 19 (Light Amber) = DMX 80 - 83
Color Preset 20 (Steel Blue) = DMX 84 - 87
Color Preset 21 (Lt Green/Blue) = DMX 88 - 91
Color Preset 22 (Orange) = DMX 92 - 95
Color Preset 23 (Medium Pink) = DMX 96 - 99
Color Preset 24 (Cyan) = DMX 100 - 103
Color Preset 25 (Purple) = DMX 104 - 107
Color Preset 26 (Custom) = DMX 108 - 111
Color Preset 27 (Custom) = DMX 112 - 115
Color Preset 28 (Custom) = DMX 116 - 119
Color Preset 29 (Custom) = DMX 120 - 123
Color Preset 30 (Custom) = DMX 124 - 127
Color Preset 31 (Custom) = DMX 128 - 131
No Preset Activated = DMX 253 - 255

Summary of Contents for PLZS1MKII-1834-03

Page 1: ...For PLZS1MKII 1834 03 PLZS1MKII 2444 03 ...

Page 2: ...en Le matériel décrit dans ce manuel est pour information seulement et est sujet à changements sans préavis La compagnie Philips Selecon n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s il vous plait contacter le bureau de Philips Selecon le plus proch...

Page 3: ...ure failure of the LED engine When using electrical equipment basic safety precautions should always be followed including the following a READ AND FOLLOW ALL SAFETY INSTRUCTIONS b Do not use outdoors c Do not mount near gas or electric heaters d Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel e The use of access...

Page 4: ...are Cable 4 PLPROFILE1 MKII LED Luminaire Top Box Assembly 4 PLPROFILE1 MKII LED Luminaire OVERVIEW PLPROFILE1 MKII LED Luminaire Components 5 Major Luminaire Components 5 Top Box PLICB Luminaire Connections 6 LCD Display Menu System 6 INSTALLATION AND SET UP Power Requirements 7 Connecting Power 7 Connecting to the DMX512 Network 8 Mounting 9 Using Supplied C Clamp 9 Safety Cable Use 10 Pan and T...

Page 5: ... Channel Detail 25 PLPROFILE1 MKII LED Luminaire RDM Parameter IDs 31 CLEANING AND CARE Special Cleaning and Care Instructions 34 Lens Tray Assembly Cleaning 34 Service and Maintenance 35 Accessories 35 TROUBLESHOOTING Troubleshooting Guide 36 TECHNICAL SPECIFICATIONS PLPROFILE1 MKII LED Luminaire Operational Specifications 37 PLPROFILE1 MKII LED Luminaire Dimensions 37 ...

Page 6: ... Power Input Cable 39 inches 1 meter Powercon without Connector user to supply AC connector PC1GP PLPROFILE1 MKII LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon with Stagepin Connector PC1GTL PLPROFILE1 MKII LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon with Twistlock Connector PC1GR PLPROFILE1 MKII LED Luminaire AC Power Input Cable 39 inches 1 meter Powercon with E...

Page 7: ... LED Luminaire Components For the LCD Display Menu System refer to LCD Display Menu System on page 6 for more information Front of Unit Rear of Unit Lens Tube Assembly Top Box Assembly PLICB AC Input Thru and DMX In Out Connections Safety Cable Anchor Point Beam Angle Adjustment Beam Focus Adjustment Beam Shutter 4 each Yoke Locking Handle LCD Display Menu System Multi Conductor Fixture Connection...

Page 8: ...LED Luminaire LCD Display Menu System DMX512 Output Thru DMX512 Input AC Power Output AC Power Input Multi Conductor Top Box to Luminaire Connection Multi Conductor Top Box to Luminaire Connection Side View 1 Side View 2 1 LCD Display Menu System 2 Preset Intensity Menu Access Buttons 3 Function Menu System Select Push Buttons 1 Note For Menu operation and programming details refer to LCD Menu Ope...

Page 9: ...nch circuit protected by a maximum 20 Amp circuit protector Doit être alimenté par un circuit de dérivation protégé par un maximum de 20 ampères circuit protecteur b When using the daisy chain connection method ONLY connect PLPROFILE1 MKII LED Luminaires to AC Output Connection of PLPROFILE1 MKII LED Luminaires DO NOT CONNECT OTHER TYPES OF LUMINAIRES OR DEVICES c Use only approved cable types d D...

Page 10: ...r DMX512 device to be controlled Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page 1 For PLPROFILE1 MKII LED Luminaire DMX Mapping refer to DMX CONTROL on page 21 Figure 4 PLPROFILE1 MKII LED Luminaires DMX512 Connections Wire Color Purpose Brown Main Line 100 to 240VAC Blue Neutral Green Yellow Ground Neutral Main Ground Earth Line AC Inpu...

Page 11: ...minaire Mounting To mount on a telescopic stand reverse the yoke under the luminaire and bolt to stand Please note luminaire orientation see note in Figure 5 for proper cooling Note After installing Clamp and Top Box assembly connect luminaire cable assembly to Top Box Assembly before mounting luminaire Please note that the cable connector is keyed Yoke Assembly Center Clamp Mounting Hole 13 mm NO...

Page 12: ...e between 0 to 90 degrees When the yoke is in the position shown in Figure 6 you have full range access to shutters the gate etc If you flip the yoke over some access is reduced but the over all volume the luminaire takes up is reduced This is particularly useful in tightly hung lighting positions or in theatres with low grids Figure 6 Luminaire Tilt Adjustment To adjust and set tilt angle of the ...

Page 13: ...operly supported Figure 7 Lens Tray Assembly Removal Step 3 With lens tray assembly open hanging down lift lens tray assembly up and out of its hinged position to free it from luminaire Step 4 To install perform process in reverse CAUTION Ensure the lens tray assembly locking catch is fully engaged before putting fixture into use 2 Zoom and Focus Adjustments To adjust zoom beam angle and focus Ste...

Page 14: ...h PLPROFILE1 MKII LED Luminaire is equipped with four independent shutters as shown in Figure 9 to block or shape light as desired After the luminaire is installed and positioned move the shutters in or out as desired Figure 9 PLPROFILE1 MKII LED Luminaire Beam Shutters Zoom Adjustment Knob Shutter 4 ea Focus Adjustment Knob Lens Tray Assembly Beam Shutter 4 each Front View Move beam shutters in a...

Page 15: ...rchased from your local Authorized Dealer For more information refer to PLPROFILE1 MKII LED Luminaire Imaging Accessories on page 4 To install or change a gobo Step 1 As shown in Figure 10 locate gobo iris access slot Step 2 Install gobo into gobo holder in desired orientation Step 3 Slide gobo holder into luminaire gobo slot making sure to catch slots in interior of gobo slot closest to shutters ...

Page 16: ...ss will appear after power up Figure 11 LCD Display and Menu System Up Down Left Right Arrow Buttons Navigates menu system and used for Escape ESC Menu Button Enters menu options Navigates OK Enter Button Accesses details activates a field or enters a setting depending on the current menu item selecting and setting options backs up one menu level PRESET Button Allows the recall of LCD Display Disp...

Page 17: ...s Step 2 Press OK at desired menu item to access and make changes Step 3 Make changes as desired Note When DMX512 signal is present Edit Preset and Color Mixer options will not appear in menu structure To navigate fixture status menus Step 1 At default screen press LEFT or RIGHT arrow button once The default menu screen will change to allow for quick reference to the following items note depending...

Page 18: ...us recallable presets in the fixture using arrow buttons Note To edit a current set preset see Edit Presets Off Users can Save the current settings look to a specific recallable Preset in the fixture s memory Edit the levels values for Red Green Blue White and Intensity values in percent by using the arrow buttons Once the values are adjusted the preset is saved as desired Only intensities may be ...

Page 19: ... Color Mix is changed 5 thru 25 an asterisk is appended to the end of the name to indicate that it has been modified This only happens if the name matches the original calibrated name stored in EEPROM This does not happen if the Intensity is changed only the color mix Scratch Pad Warm White Cool White Day Light Preset X 5 through 31 Note When DMX512 signal is present Edit a Preset option will not ...

Page 20: ...it user selectable PIN code Step 4 Use LEFT ARROW or RIGHT ARROW keys to highlight YES press OK or ESC twice to cancel action Step 5 Fixture is now locked if locking process was not canceled as described in previous step Continued from previous page Lock Fixture Sub Menu Options Comments Enter PIN Lock Are you sure Use arrow buttons to make selection Press OK to accept Note a PIN code must be esta...

Page 21: ...alues have been changed Note DMX will take priority over any menu selected preset Editing Preset Names On the Edit Preset screen the option is available to edit the name of a preset via Screen button However the names of Presets 0 2 3 and 4 cannot be edited Scratch Pad preset 1 can be changed but retains its original functionality Use the LEFT ARROW and RIGHT ARROW keys to select the character to ...

Page 22: ... luminaire s operational hours Set PIN 0 0 0 0 four zeros A four digit user settable PIN code to lock the fixture Presets Protected No 5 25 5 25 Determines if the factory Presets Color Mix is protected from changes Load Factory No Yes No Reload Factory Presets Intensity changes will also be reloaded DMX Address 001 to 512 001 DMX512 address Note it can be set if displayed Map 8 bit 16 bit or 5 Cha...

Page 23: ... 0 100 0 16 bit control of White LEDs from 0 to full 10 White Low Byte 11 Preset Color Selection 0 255 0 100 0 Used to access presets stored in fixture firmware such as CCT presets defined gel presets etc No Preset Activated DMX 0 3 default Color Preset 0 Off DMX 4 7 Color Preset 1 Scratch Pad DMX 8 11 Color Preset 2 Warm White DMX 12 15 Color Preset 3 Cool White DMX 16 19 Color Preset 4 Daylight ...

Page 24: ...reset 1 Store DMX 20 21 Preset 2 Store Intensity Only DMX 22 23 Preset 3 Store Intensity Only DMX 24 25 Preset 4 Store Intensity Only DMX 26 27 Preset 5 Store DMX 28 29 Preset 6 Store DMX 30 31 Preset 7 Store DMX 32 33 Preset 8 Store DMX 34 35 Preset 9 Store DMX 36 37 Preset 10 Store DMX 38 39 Preset 11 Store DMX 40 41 Preset 12 Store DMX 42 43 Preset 13 Store DMX 44 45 Preset 14 Store DMX 46 47 P...

Page 25: ... Color Preset 5 Arc White DMX 24 27 Color Preset 6 Red DMX 28 31 Color Preset 7 Yellow DMX 32 35 Color Preset 8 Daylight Blue DMX 36 39 Color Preset 9 Magenta DMX 40 43 Color Preset 10 Aqua DMX 44 47 Color Preset 11 Medium Amber DMX 48 51 Color Preset 12 Lavender DMX 52 55 Color Preset 13 Blue DMX 56 59 Color Preset 14 Light Pink DMX 60 63 Color Preset 15 Green DMX 64 67 Color Preset 16 Pink DMX 6...

Page 26: ...37 Preset 10 Store DMX 38 39 Preset 11 Store DMX 40 41 Preset 12 Store DMX 42 43 Preset 13 Store DMX 44 45 Preset 14 Store DMX 46 47 Preset 15 Store DMX 48 49 Preset 16 Store DMX 50 51 Preset 17 Store DMX 52 53 Preset 18 Store DMX 54 55 Preset 19 Store DMX 56 57 Preset 20 Store DMX 58 59 Preset 21 Store DMX 60 61 Preset 22 Store DMX 62 63 Preset 23 Store DMX 64 65 Preset 24 Store DMX 66 67 Preset ...

Page 27: ...zero to 169 seconds To use a timing channel instead of console timing it is recommended to set the timing channel to the desired value and set cue and or console cue fade time to zero A combination of time controls can produce unexpected results The default value setting in the profile should be 255 proportional control to allow smooth operation when using console timing The timing channel data sh...

Page 28: ... 2 22 4 4 9 23 4 6 24 4 8 10 25 5 26 5 2 27 5 4 11 28 5 6 29 5 8 30 6 12 31 6 2 32 6 4 13 33 6 6 34 6 8 35 7 0 14 36 7 2 37 7 4 15 38 7 6 39 7 8 40 8 16 41 8 2 42 8 4 17 43 8 6 44 8 8 45 9 18 46 9 2 47 9 4 19 48 9 6 49 9 8 50 10 20 51 10 2 52 10 4 53 10 6 21 54 10 8 55 11 22 56 11 2 57 11 4 58 11 6 23 59 11 8 60 12 24 61 12 2 Value DMX Seconds ...

Page 29: ... 14 2 72 14 4 73 14 6 29 74 14 8 75 15 30 76 15 2 77 15 4 78 15 6 31 79 15 8 80 16 81 16 2 32 82 16 4 83 16 6 33 84 16 8 85 17 86 17 2 34 87 17 4 88 17 6 35 89 17 8 90 18 91 18 2 36 92 18 4 93 18 6 37 94 18 8 95 19 96 19 2 38 97 19 4 98 19 6 39 99 19 8 100 20 101 21 40 102 22 103 23 104 24 41 105 25 106 26 42 107 27 108 28 109 29 43 110 30 111 31 44 112 32 113 33 114 34 45 115 35 Value DMX Seconds...

Page 30: ... 47 50 128 48 129 49 51 130 50 131 51 132 52 52 133 53 134 54 53 135 55 136 56 137 57 54 138 58 139 59 55 140 60 141 61 142 62 56 143 63 144 64 57 145 65 146 66 147 67 58 148 68 149 69 59 150 70 151 71 152 72 60 153 73 154 74 155 75 61 156 76 157 77 62 158 78 159 79 160 80 63 161 81 162 82 64 163 83 164 84 165 85 65 166 86 167 87 66 168 88 169 89 Value DMX Seconds ...

Page 31: ... 181 101 182 102 183 103 72 184 104 185 105 73 186 106 187 107 188 108 74 189 109 190 110 75 191 111 192 112 193 113 76 194 114 195 115 77 196 116 197 117 198 118 78 199 119 200 120 79 201 121 202 122 203 123 80 204 124 205 125 81 206 126 207 127 208 128 82 209 129 210 130 211 131 83 212 132 213 133 84 214 134 215 135 216 136 85 217 137 218 138 86 219 139 220 140 221 141 87 222 142 223 143 Value D...

Page 32: ...d default will provide the smoothest timing 88 224 144 225 145 226 146 89 227 147 228 148 229 149 90 230 150 231 151 91 232 152 233 153 234 154 92 235 155 236 156 93 237 157 238 158 239 159 94 240 160 241 161 95 242 162 243 163 244 164 96 245 165 246 166 97 247 167 248 168 249 169 98 250 60mS 251 80mS 99 252 100mS 253 120mS 254 140mS 100 255 default 160mS Value DMX Seconds ...

Page 33: ...DM UID UID MSB of ESTA 50H LSB of ESTA 41H 1st of Unique Seq 2nd of Unique Seq 3rd of Unique Seq 4th of Unique Seq Table 6 PLPROFILE1 MKII LED Luminaire RDM Parameters IDs Get Allowed Set Allowed RDM Parameter IDs Value Comment Implemented Category Network Management DISC_UNIQUE_BRANCH 0x0001 DISC_MUTE 0x0002 DISC_UN_MUTE 0x0003 PROXIED_DEVICES 0x0010 PROXIED_DEVICES_COUNT 0x0011 COMMS_STATUS 0x00...

Page 34: ...ITION 0x0200 SENSOR_VALUE 0x0201 RECORD_SENSORS 0x0202 Category Dimmer Settings 0x03xx FUTURE USE Category Power Lamp Settings 0x04xx DEVICE_HOURS 0x0400 LAMP_HOURS 0x0401 LAMP_STRIKES 0x0402 LAMP_STATE 0x0403 LAMP_ON_MODE 0x0404 DEVICE_POWER_CYCLES 0x0405 Category Display Settings 0x05xx DISPLAY_INVERT 0x0500 DISPLAY_LEVEL 0x0501 Category Configuration 0x06xx PAN_INVERT 0x0600 TILT_INVERT 0x0601 ...

Page 35: ...r IDs Value Comment Implemented Table 7 PLPROFILE1 MKII LED Luminaire RDM Manufacturer Status IDs Manufacturer Specific messages are in the range of 0x8000 0xFFDF Each Manufacturer specific Status ID shall have a unique meaning which shall be consistent across all products having a given Manufacturer ID See Table B 2 ANSI E1 20 2010 Status ID Message Value Data Value 1 Data Value 2 Status ID Descr...

Page 36: ...D Luminaire Lint free lens tissue Lint or powder free gloves Reagent grade isopropyl alcohol A mild soap solution Note Reagent grade isopropyl alcohol is good to use on the PLPROFILE1 MKII LED Luminaire optics with anti reflection coatings If the lens is still dirty after using isopropyl alcohol for instance if fingerprints or oil is just redistributed and not cleaned off the optics then a mild so...

Page 37: ...t your local Philips Selecon office or an Authorized Service Center WARNING Disassembly other than as described herein alterations unauthorized service etc will void the product warranty Contact your local Philips Selecon office or an Authorized Service Center for technical support and service 4 Accessories Only Philips Selecon approved accessories should be used with your PLPROFILE1 MKII LED Lumi...

Page 38: ...xture will not respond to DMX commands Not detecting DMX data Disconnect and reconnect DMX input cable Unit is not set to be controlled by DMX check menu settings Check all DMX connections at control source and luminaire DMX data cable not wired correctly or has a broken conductor check DMX data cable for proper wiring See Connecting to the DMX512 Network on page 8 for more information LED light i...

Page 39: ...t 1 2 Amps 115VAC 0 6 Amps 230VAC Frequency 50 60Hz Ambient Temperature 0 to 40 degrees C 32 to 104 degrees F Humidity 5 95 Non condensing Cooling Forced Air Weight 17 2 lbs 7 8 kg Luminaire and topbox only no mount AC input cable or accessories Compliance cETLus Listed CE and C Tick Marked Note Common model specifications shown For specific model specifications features and accessories refer to t...

Page 40: ......