Installation & User’s Manual
PLFRESNEL1 MKII LED Luminaires
8
INSTALLATION AND SET UP
Table 1:
PLFRESNEL1 MKII LED Luminaire AC Input
Connections
3. Connecting to the DMX512 Network
Basic DMX512 installation consists of connecting multiple PLFRESNEL1 MKII LED Luminaires together (up to 30
luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX
connector on the first PLFRESNEL1 MKII LED Luminaire. Another cable runs from the other DMX connector on
the first unit to a DMX connector on the next PLFRESNEL1 MKII LED Luminaire (or DMX512 device to be
controlled).
Note:
For more information on DMX512 networking and systems, refer to
"Additional Resources for DMX512" on
. For PLFRESNEL1 MKII LED Luminaire DMX Mapping, refer to
.
Figure 4: PLFRESNEL1 MKII LED Luminaires - DMX512 Connections
Wire Color
Purpose
Brown
Main / Line (120 to 240VAC)
Blue
Neutral
Green/Yellow
Ground
Neutral
Main /
Ground / Earth
Line
AC Input Connector
(on back of unit)
DMX512
DMX512
(out from first
to second luminaire)
DMX512
(out to the next luminaire or
DMX512 controlled device)
PLFRESNEL1 MKII LED Luminaires
(from console or
control device)
DMX512 Connections
Data Thru
Cable Pinout
Male Conn
Pin 1
Common
(Drain)
Pin 2
Data (-)
Pin 3
Data (+)
Pin 4
Not Used
Pin 5
Not Used
Data In
Cable Pinout
Female Conn
1
2
3
4
5
1
2
3
4
5
Summary of Contents for PLFRESNEL1