Service Modes, Error Codes, and Fault Finding
5.
How to Exit CSM
Press “MENU” on the RC-transmitter.
5.1.2
Service Alignment Mode (SAM)
How to enter
To enter the factory mode, use the following method:
•
Press the following key sequence on the remote control
transmitter: “0 6 2 5 9 6 INFO”.
After entering the factory mode, the following screen is visible
on the top and right of the panel.
How to Navigate
With the up/down cursor keys can be used to navigate through
the menu, while with the Left/Right cursor the values can be
changed.
How to EXIT
Choose “EXIT”, and press the “OK” button.
Figure 5-4 Example of SAM
Table 5-1 Contents of SAM
1
88
60_20
3
_100429.ep
s
100429
Action Items
Range
Default Value
Description
19"
22"
26"
Brand
PHILIPS
PHILIPS
PHILIPS
brand customer
Ver
TPN1 1E 2.01
TPN1 1E 2.01
TPN1 1E 2.01
software version
Date
Apr 21 2010
Apr 21 2010
Apr 21 2010
software release date
Model name
19PFL3405/12
22PFL3405/12
26PFL3405/12
model name
Scaler
NT72632
NT72632
NT72632
scaler IC type
Panel type
LC185EXN-SCA1(119) LC216EXN-SCA1(120) LC260EXN-SCB1(121) panel type and display code
Current source
TV
TV
TV
select source
Auto color
GO
GO
GO
PC: any pattern has black and white YPbPr: SMPTEbar (colour bar), any
timing.
ADC offset
0 - 255
R 0
G 0
B 0
R 0
G 0
B 0
R 0
G 0
B 0
PC: any pattern has black and white YPbPr: SMPTEbar (colour bar), any
timing.
ADC gain
0 - 255
R 0
G 0
B 0
R 0
G 0
B 0
R 0
G 0
B 0
PC: any pattern has black and white YPbPr: SMPTEbar (colour bar), any
timing.
Color temp
Normal
Normal
Normal
colour temperature, normal, cool, warm
Scaler offset
0 - 255
R 128
G 128
B 128 R 128
G 128
B 128 R 128
G 128
B 128 Back-End Scaler R G B Gain NVM has YPbPr NORMAL, WARM, COOL,
CUSTOMER four sets. Other source use offset with hardcoding
Scaler gain
0 - 255
R 113
G 126
B128
R 102
G 121
B128
R 127
G 127
B123
Back-End Scaler R G B Gain NVM has YPbPr NORMAL, WARM, COOL,
CUSTOMER four sets. Other source use offset with hardcoding
Burn in
Off
Off
Off
Puts the set in Burn In mode, for factory use only
EEPROM init
GO
GO
GO
resets the EEPROM to initial mode
Backlight time
x hours
x hours
x hours
the set backlight running time
Error code
000 000 000 000 000
000 000 000 000 000
000 000 000 000 000
error code layer 2. Store in NVM.
Clear error code
GO
GO
GO
clears error code Layer 2. in NVM.
Reset PBS setting
GO
GO
GO
resets the PBS setting
Virgin mode
Off
Off
Off
resets the set to manufacturer's mode
ACI
On
On
On
ACI on or off
ATS
On
On
On
ATS on or off
NVM address
0×0 (0)
0×0 (0)
0×0 (0)
NVM address
NVM value
0×49 (73)
0×55 (85)
0×35 (53)
NVM value NVM
NVM copy to USB
GO
GO
GO
use this to copy the NVM data from the TV to the USB
NVM paste from USB
GO
GO
GO
use this to restore the NVM data from the USB to the TV
Exit
Press OK
Exit from factory mode