background image

8

6. 

Caution

: The mounting flange is provided with pre-punched 

holes, never leave holes or slots unsealed; water can penetrate.  

Caution:

Fasteners should be installed so spacing is not more 

than 10" on center (see figure 4), but may be installed closer 

together if so desired.  Continue installation of the rest of the 

fasteners starting in the center of each member and progressing 

out to the corners.  Fasteners must be installed close enough 

together to ensure the sealant on the back of mounting flange 

makes full contact with the exterior perimeter of the R.O.

7.  

Note:

One (1) fastener must be installed at each corner so that 

it is within ¾” to 1¼” of the end of the frame member extrusion 

joined to form the corner (see figure 4).

O

PTIONAL

I

NSTALLATION

P

ROCEDURES

Insulation – Insulate between the window frame and the interior of the R.O.

at both jambs and at the head.  

Caution

:  Do not over pack insulation, as

bowed frame/jambs may result.  Expandable foam type material may bow

frame also, causing improper operation of the unit.

Cleaning – Do not use abrasive cleaners on the glass as they may perma-

nently scratch or mar the surface.  Any cleaners, other than a mild deter-

gent and soft cloth, should be tried in a small corner of the window so as to

check whether they damage the finish.

Weather-stripping, hardware components, tracks or vinyl components

should not be painted or stained.

Flashing – Philips recommends the use of flashing for proper drainage.

Reference Section 16 (New Construction Installations) of AAMA Installer

Certification Manual.  It is also acceptable to use a “house wrap system”

that is sealed and allows no opportunity for water to penetrate behind the

mounting flange to the interior wall cavity.

When using staple guns to install vinyl windows and sliding doors, it it not

necessary that one leg of the staple pass through the nailing fin hole.  Care

must be taken to not break the fin.  If a fin is cracked or the staple blows

through the fin, it must be repaired by sealing the crack with sealant and

placing a properly installed staple 1” or 2” on each side of the blow through.

O

PTIONAL

F

IELD

M

ULLING

/S

TACKING

P

ROCEDURES

(Series 800 Windows Only)

For mulling/stacking instructions use Lit-1607. 

9

Figure 5

C

ASEMENT

I

NSTALLATION

P

ROCEDURES

1.

Install the window per steps 1 through 5 under window installation.

2.

Install the head and frame/jamb flashing per steps 1 through 5 as 

instructed previously.

3.

Open all operable sashes to remove the shipping clips installed, on 

the top and bottom of the sash, farthest away from the hinges.  

Note:

The clips are applied with adhesive and must be removed for 

proper operation.

Summary of Contents for Manufactured Housing Vinyl Window

Page 1: ...MANUFACTURED HOUSING VINYL WINDOW INSTALLATION INSTRUCTIONS EXCLUDES STORM WINDOWS PHILIPS PRODUCTS PHONE NUMBER 574 296 0000 LIT 1610 3 05 REV 2 PRODUCTS PHILIPS ...

Page 2: ...ducts and methods used in construction and installation conform to all applicable building codes and regulations 4 For casement style windows see page 9 for additional instructions 5 Do not leave windows in direct sunlight when wrapped ROUGH OPENING PREPARATION 1 Make certain the rough opening referred to as R O in the remainder of document is correctly sized and constructed The R O must be greate...

Page 3: ...will not seat flat against the exterior perimeter of the R O If damaged or distorted straighten the mounting flange so that it will make contact with the exterior face of the wall or contact Philips Products Inc for instructions 4 Windows must always be closed and locked during installation Make sure there are no gaps or voids between the window mounting flange and the exterior perimeter of the R ...

Page 4: ...nimum of 1 penetration into the framing members 3 While holding the window flat against the exterior of the wall start a fastener in the approximate center of one of the frame jamb mounting flanges Continue installing fasteners in the following order center of opposite frame jamb center of head and center of sill Note If scaffolding interferes with the top of the window it is acceptable to install...

Page 5: ...rner of the window so as to check whether they damage the finish Weather stripping hardware components tracks or vinyl components should not be painted or stained Flashing Philips recommends the use of flashing for proper drainage Reference Section 16 New Construction Installations of AAMA Installer Certification Manual It is also acceptable to use a house wrap system that is sealed and allows no ...

Page 6: ...ch Truth part number 31887 onto the base of the stud found between the support arm and the track of the lower hinge Swinging the wrench away from the lock side window will decrease the amount of sash drag The maximum sash drag adjustment is reached when the stud flats are parallel to the track Note turning the stud flats beyond parallel will not increase sash drag correction 3 For severe sash drag...