LF Generator
e.g. PM5110
Recorder
Use Universal Test Cassette
CrO2
SBC419 4822 397 30069
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter
S/N and distortion meter
e.g. Sound Technology ST1700B
L
R
DUT
or Universal Test Cassette
Fe
SBC420 4822 397 30071
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter
S/N and distortion meter
e.g. Sound Technology ST1700B
L
R
DUT
CD
Use Audio Signal Disc
(replaces test disc 3)
SBC429 4822 397 30184
Bandpass
250Hz-15kHz
e.g. 7122 707 48001
LF Voltmeter
e.g. PM2534
DUT
S/N and distortion meter
e.g. Sound Technology ST1700B
Frame aerial
e.g. 7122 707 89001
Tuner AM (MW,LW)
To avoid atmospheric interference all AM-measurements have to be carried out in a Faraday´s cage.
Use a bandpass filter (or at least a high pass filter with 250Hz) to eliminate hum (50Hz, 100Hz).
RF Generator
e.g. PM5326
Ri=50
Ω
Bandpass
250Hz-15kHz
e.g. 7122 707 48001
LF Voltmeter
e.g. PM2534
DUT
RF Generator
e.g. PM5326
S/N and distortion meter
e.g. Sound Technology ST1700B
Use a bandpass filter to eliminate hum (50Hz, 100Hz) and disturbance from the pilottone (19kHz, 38kHz).
Ri=50
Ω
Tuner FM
MEASUREMENT SETUP
1-4
Summary of Contents for LX2600D
Page 33: ...7 11 7 11 PCB 31311352 pt3 TOP VIEW MAPPING ...
Page 35: ...7 13 7 13 PCB 3139 113 3522 pt3 BOTTOM VIEW MAPPING ...
Page 38: ...8 2 8 2 MECHANICAL EXPLODED VIEW 0010 0006 TECHNICAL REMARKS ...
Page 47: ...MAIN ENCASING EXPLODED VIEW 10 1 10 1 ...