Any unauthorized modification to this equipment could result in the revocation of the autho-
rization to operate the equipment.
Lenses
The camera is provided with a standard CS-mount.Therefore, a wide range of lenses can be
used. For example:
•
fixed iris lenses
•
manual iris lenses
•
DC auto-iris lenses
•
active auto-iris lenses
Notes
1.
For indoor use, you can use a fixed iris lens. For outdoor applications, a DC or active auto-
iris lens is recommended.
2.
Try to avoid bright light sources in the camera’s field of view when you use a fixed iris lens.
They may cause smear in the picture.
When you use a DC or active auto-iris lens, the smear will be reduced.
3.
When you use a DC or active iris lens, it is recommended to set the Auto Electronic
Shutter (AES switch; 8) to the ‘OFF‘ position.
4.
When an C/CS-mount adapter (optional) is used, C-mount lenses can also be applied.
Installation (Figure 1, 2 & 3)
a
Use this screw hole to mount the camera. Maximum allowed length of the screw is 8mm.
The screw block can be mounted on the top or bottom side of the camera.
Note: Take care to use the original screws (M2 x 6), when mounting the screwblock on
the top side.
b
The camera is equipped with a standard CS-mount. For C-mount lenses, an optional C to
CS adapter-ring must be used.
c
Back-focus locking screw (must be released before setting the focus with the back-focus
adjustment screw).
d
Back-focus adjustment screw (see back-focus adjustment).
e
Power input/Terminal block.
Low voltage camera
Power input rating:
-
CCIR: 12 - 24 V~(AC) or 12 - 30 V––
7
(DC) + 10%, - 10%
-
EIA: 12 - 28 V~(AC) or 12 - 36 V––
7
(DC) + 10%, - 10%
Recommended operating voltage:
-
12 V––