background image

3

SAFETY PRECAUTIONS

CAUTION

RISK OF ELECTRIC

SHOCK. DO NOT OPEN! 

CAUTION: TO REDUCE THE RISK OF
ELECTRICAL SHOCK, DO NOT OPEN
COVERS.  NO USER SERVICEABLE PARTS
INSIDE.  REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

This label may appear on the bottom of the unit due to
space limitations.

The lightning flash with an arrowhead symbol, within
an equilateral triangle, is intended to alert the user
to the presence of uninsulated "dangerous voltage"
within the product's enclosure that may be of
sufficient magnitude to constitute a risk of electric
shock to persons.

The exclamation point within an equilateral triangle
is intended to alert the user to presence of
important operating and maintenance (servicing)
instructions in the literature accompanying the
appliance.

Warning

To prevent fire or shock hazard, do not expose
this unit to rain or moisture.

CONTENTS

1 UNPACKING................................................................3

3 DESCRIPTION .............................................................3

4 INSTALLATION ..........................................................3
4.1 Models.............................................................................................3
4.2 Low Voltage Operation .............................................................3
4.3 Camera/Lens Installation............................................................3

5 ILLUSTRATION...........................................................6

6 RECOMMENDED APPLICATIONS .........................7

7 PARTS LIST ..................................................................8

1

UNPACKING

Unpack carefully. This is electro-mechanical equipment and
should be handled with care.

Check for the following items:

--

Model number of unit.

--

Installation and Operating Instructions.

If an item appears to have been damaged in shipment,
replace it properly in its carton and notify the shipper.  If any
items are missing, notify your Philips Communication &
Security Systems Inc. Sales Representative or Customer
Service.

The shipping carton is the safest container in which the unit
may be transported.  Save it for possible future use.

2

SERVICE

If the unit ever needs repair service, the customer should
contact the nearest Philips Communication & Security
Systems Inc. Service Center for return authorization and
shipping instructions.

Service Centers
U.S.A. & Canada: 800-366-2283
Mexico & Central America: 52-5-564-2726
Europe & Middle East: 44-1932-765666
South America: 54-1-956-0837
Australia: 61-2-888-9000
New Zealand: 64-4-237-7297

3

DESCRIPTION

The LTC 9350 Series of environmental housings are
attractive aluminum enclosures designed for indoor CCD
camera installations.  Slim and compact, the LTC 9350 Series
are available in three lengths.

4

INSTALLATION

THIS INSTALLATION SHOULD BE MADE
BY QUALIFIED SERVICE PERSONNEL AND
SHOULD CONFORM TO ALL LOCAL
CODES.

4.1

Models

LTC 9352/00:

Accepts cameras up to 64 W x 54 H mm (2.5 x 2.1 in),
lenses up to 58 W x 64 H mm (2.3 x 2.5 in), and
camera/lens combinations up to 190 mm L (7.5 in).

LTC 9352/01:

Accepts cameras up to 64 W x 54 H mm (2.5 x 2.1 in),
lenses up to 58 W x 64 H mm (2.3 x 2.5 in), and
camera/lens combinations up to 216 mm (8.5 in).

Caution:  For UL and cUL Approved
LTC 9352/01 Models, Use only Class 2 power
source with this unit.

LTC 9353/00:

Accepts cameras up to 64 W x 54 H mm (2.5 x 2.1 in),
lenses up to 58 W x 64 H mm (2.3 x 2.5 in), and
camera/lens combinations up to 224 mm L (8.8 in).

LTC 9358/00:

Accepts cameras up to 64 W x 54 H mm (2.5 x 2.1 in),
lenses up to 58 W x 64 H mm (2.3 x 2.5 in), and
camera/lens combinations up to 325 mm L (12.8 in).

See RECOMMENDED APPLICATIONS.

4.2

Low Voltage Operation

Do not exceed 30 VAC input on 24 VAC model cameras.
Operation above 30 VAC violates low voltage operation
(Class 2 Specifications).  Normal operation is 24 VAC.

4.3

Camera/Lens Installation

Note:  LTC 9352/01 Models do not contain a wiring
terminal block.

1.

Remove the two (2) 6-32 x 1/2-inch long Phillips head
screws from the end cap.  See Figure 1.

Summary of Contents for LTC 9350 Series

Page 1: ...Eng F Indoor Housings LTC 9350 Series Philips Communication Security Systems D E NL I ...

Page 2: ...ords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords and plugs convenience receptacles and the point where they exit from the appliance 13 Power Lines An outdoor system should not be located in the vicinity of overhead power lines or other electric light or power circuits or where it can fall into suc...

Page 3: ... repair service the customer should contact the nearest Philips Communication Security Systems Inc Service Center for return authorization and shipping instructions Service Centers U S A Canada 800 366 2283 Mexico Central America 52 5 564 2726 Europe Middle East 44 1932 765666 South America 54 1 956 0837 Australia 61 2 888 9000 New Zealand 64 4 237 7297 3 DESCRIPTION The LTC 9350 Series of environ...

Page 4: ...er Is In Place W9407404AE Mounting Position For TC9948 6X Zoom Lens Use 1 4 20 Screw Provided Figure 4a Camera Zoom Lens Mounting Positions LTC 9353 00 and LTC 9358 00 Only Note Refer to section 5a for LTC 9352 01 model power wiring instructions 5 When installing 120 or 220 volt cameras the camera power cord must be cut leaving enough cable to strip and attach to the terminal block Strip no less t...

Page 5: ...g Cradle BNC Connector Terminal Block W9407407AE Figure 7 BNC Connection 7 If installing a zoom lens insert the lens control cable through the lower left fitting of the end cap Attach the lens wiring to the lens mating connector if supplied and connect to the lens If a mating connector is not available connect directly to the lens cables Pull any excess wire out of the cradle assembly Tighten the ...

Page 6: ... Thick Front View 111 4 4 51 2 0 Side View 95 3 8 mm in 274 10 8 TC9352 330 13 0 TC9353 433 17 0 TC9358 Bottom View 76 3 0 38 1 5 2x 25 1 0 333 13 1 TC9352 391 15 4 TC9353 493 19 4 TC9358 W9406400BE Figure 9 Dimensional Outline ...

Page 7: ...0 VAC 24 VAC 12 VDC Fixed Fixed Fixed TC9938 TC9948A TC652BT 24 VAC Fixed Fixed TC9948A TC652B 24 VAC Fixed Fixed Fixed TC9948A Fixed TC9948A TC952 24 VAC Fixed Fixed Fixed Fixed TC972 24 VAC Fixed Fixed Fixed Fixed 50 Hz Cameras LTC 0142 50 220 VAC with 3 mm lens with 3 mm lens with 3 mm lens with 3 mm lens LTC 0143 50 220 VAC with 6 mm lens with 6 mm lens with 6 mm lens with 6 mm lens LTC 0142 1...

Page 8: ...A TC9938 TC554AX 220 240 VAC Fixed Fixed TC9948A TC9938 TC594X 220 240 VAC Fixed Fixed Fixed TC9938 TC9948A TC654BX 220 240 VAC Fixed Fixed TC9948A Suggested CS Mount Auto Iris Fixed and Zoom Lenses TC9902 1 3 inch 2 8 mm f 1 2 fixed TC9904 1 3 inch 4 mm f 1 2 fixed TC9908 1 3 inch 8 mm f 1 2 fixed TC9903A 1 2 inch 3 7 mm f 1 6 fixed TC9906A 1 2 inch 6 mm f 1 4 fixed TC9907 1 2 inch 6 mm f 1 4 fix...

Page 9: ...8 Ring Tongue Terminal 22 1 8 Lock Washer 23 1 M4 x 8 Screw 17 inch Cradle Assembly Kit 315 2792 001 7 1 17 inch Cradle Assembly 15 1 1 Terminal Block 16 1 1 M2 5 x 12 Screw 18 1 1 M2 5 PEM Nut 19 1 17 inch Plastic Sunshield 21 1 8 Ring Tongue Terminal 22 1 8 Lock Washer 23 1 M4 x 8 Screw End Cap Kit 315 2793 001 8 1 End Cap 10 2 8 32 x 5 8 Screw 11 1 315 1740 900 O Ring 12 1 315 1741 900 Small Fl...

Reviews: