background image

1.2

CONTENTS

1 UNPACKING

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

1.2

2 SERVICE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

1.2

3 DESCRIPTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

1.2

4 INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

1.2

4.1 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2
4.2 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2
4.3 Video Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2
4.4 Monitor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3

5 OPERATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

1.3

5.1 RUN Button and Indicator . . . . . . . . . . . . . . . . . . . . 1.3
5.2 DWELL Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3
5.3 Camera Buttons and Indicators. . . . . . . . . . . . . . . . . . 1.3

6 ILLUSTRATIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . 

1.3

6.1 LTC 5121/60, LTC 5121/50 . . . . . . . . . . . . . . . . . . . 1.3
6.2 LTC 5141/60, LTC 5141/50 . . . . . . . . . . . . . . . . . . . 1.3

1

UNPACKING

Unpack carefully. This is electronic equipment and should be
handled carefully.
Check for the following items:

Verify the model no. of unit.

If an item appears to have been damaged in shipment, replace it
properly in its carton and notify the shipper. If any items are
missing, notify your Philips Communication & Security
Systems Inc. Sales Representative or Customer Service.

The shipping carton is the safest container in which the unit
may be transported. Save it for possible future use.

2

SERVICE

If the unit ever needs repair service, the customer should contact
the nearest Philips Communication & Security Systems Inc.
Service Center for authorization to return and shipping
instructions.

Service Centers

U.S.A. & Canada: 800-366-2283
Mexico & Central America: 52-5-564-2726
Europe & Middle East: 44-1932-765666
South America: 54-1-956-0837
Australia: 61-2-888-9000
New Zealand: 64-4-237-7297

NOTE:

Grounded wrist straps must be worn and proper ESD

safety precautions observed when handling the electrostatic-
sensitive printed circuit boards.

3

DESCRIPTION

The LTC 5121/60, LTC 5121/50, LTC 5141/60 and 
LTC 5141/50 are automatic sequential video switchers.  The
LTC 5121/60 and LTC 5121/50 have 2-camera inputs and 
1-monitor output; the LTC 5141/60 and LTC 5141/50 have 
4-camera inputs and 1-monitor output.

4

INSTALLATION

4.1

Power

LTC 5121/60 and LTC 5141/60 models operate from 120
VAC, 50/60 Hz power. LTC 5121/50 and LTC 5141/50
models operate from 220-240 VAC, 50/60 Hz power.  The
model number and operating voltage are shown on the label
located on the bottom of the unit.  These units are supplied
with ground power cords; grounding should not be defeated.

4.2

Mounting

These switchers are supplied as desk-top units. For rack
mounting, the LTC 9101/00 rack-mount kit is available.

4.3

Video Inputs

The LTC 5121/60 and LTC 5121/50 both have two video
inputs labeled “CAM 1” and “CAM 2”.  The LTC 5141/60
and LTC 5141/50 both have four video inputs labeled “CAM
1”, “CAM 2”, “CAM 3”, and “CAM 4”.

The LTC 5141/60 and LTC 5141/50 incorporate an auto-skip
feature on CAM 3 and CAM 4.  If video is not supplied to
video input 4, the unit will skip over CAM 4 when sequencing
(run mode).  If video is not supplied to video input 3, the unit
will skip over CAM 3 and CAM 4 when sequencing.  When
using only 3 video inputs, use inputs CAM 1, CAM 2 and
CAM 3.  When using only 2 video inputs, use inputs CAM 1
and CAM 2.

All video inputs are 75 ohm terminated.

ATTENTION

OBSERVE PRECAUTIONS

FOR HANDLING

ELECTROSTATIC

SENSITIVE

DEVICES

WARNING: ELECTROSTATIC-SENSITIVE
DEVICE. USE PROPER CMOS/MOSFET
HANDLING PRECAUTIONS TO AVOID
ELECTROSTATIC DISCHARGE.

Summary of Contents for LTC 5121/50

Page 1: ...LTC 5121 LTC 5141 Series 2 and 4 Position Economical Sequential Switcher Philips Communication Security Systems Installation Instructions Eng F D E NL I ...

Page 2: ...Eng Installation Instructions 1 1 F Manuel d utilisation 2 1 D Installationshinweise 3 1 E Instrucciones para la instalación 4 1 NL Bedieningsvoorschrift 5 1 I Istruzioni per l installazione 6 1 i 2 ...

Page 3: ...ects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the unit 16 Servicing Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 17 Damag...

Page 4: ...i 4 ...

Page 5: ... accordance with the National Electrical Code or applicable local codes Power Disconnect Units with or without ON OFF switches have power supplied to the unit whenever the power cord is inserted into the power source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power disconnect for all units External Power Supplies Use only the Recomm...

Page 6: ...cuit boards 3 DESCRIPTION The LTC 5121 60 LTC 5121 50 LTC 5141 60 and LTC 5141 50 are automatic sequential video switchers The LTC 5121 60 and LTC 5121 50 have 2 camera inputs and 1 monitor output the LTC 5141 60 and LTC 5141 50 have 4 camera inputs and 1 monitor output 4 INSTALLATION 4 1 Power LTC 5121 60 and LTC 5141 60 models operate from 120 VAC 50 60 Hz power LTC 5121 50 and LTC 5141 50 model...

Page 7: ...the cameras are sequenced during the run mode Rotating the control clockwise slows the rate of sequencing increases the dwell time Rotating the control counter clockwise causes the switcher to sequence faster decreases the dwell time The dwell time is approximately 2 seconds when the control is turned fully counter clockwise full clockwise rotation of the control provides a dwell time of approxima...

Page 8: ...Typical Installation 1 4 ...