2 - 2
2 - 2
Software upgrade will take 5 minutes
Do not switch off!
Package version: 000029.0
Software BE Completed
Software FE Completed
Software MCU1: Not started
Software Dock: 2%
Software MCU3: Not started
Software upgrade will take 5 minutes
Do not switch off!
Package version: 000029.0
Software BE Completed
Software FE Completed
Software MCU1: 1%
Software Dock: Failed
Software MCU3:
f) The set will shut down automatically when the software upgrade
is completed.
6)How to replace the defective Blu-ray Loader
a) Remove the defective Blu-ray Loader.
b) Remove the shield cover at the top of Blu-ray Loader as shown
below.
c) Assembly Blu-ray Loader to “J802”,”J900”,”J906” on the top of
BD Board as shown below.
d) Remove soldered joint on the ESD protection points.
The ESD protection points
on the top of board.
Note: The 2 ESD protection points on any one side must be
soldered if
o the Blu-ray Loader is OK and needs to be disconnected
from connector J802, J900 and J906 of the BD Board.
o the defective Blu-ray Loader is needed to be send back to
supplier for failure analysis and to support backcharging evidence.
7)BD board and Blu-ray Loader OPU matching procedure
Note: This procedure must be performed whenever the defective
Blu-ray Loader or BD Board has been replaced .
a) Assembly Blu-ray Loader to BD Board.
b) Remove soldered joint on the ESD protection points.
c) Power on the set , press “
” <Home> button and input “5” “1”
“7” “7” on R/C.
d) Go into OSD Select mode and select item [5] ,then press <OK>
button on R/C as shown follow:
J906
J900
J802
Top side view of OPU
Bottom side view of OPU
The ESD protection points
on the bottom of board.
e) Insert empty USB device of MSC type and press <OK> button
with R/C as shown follow:
f) Using
“
”
buttons on R/C input the 6-digits OPU data
given on the 1D barcode (see label on the Loader) with the on-
screen selection and press <OK> button to save each digit entered
as shown follow:
g) Press <Back> followed by <OK> button to finish OPU matching
and “
”<Home> button to exit.
h) Repeat step c) and select item [6] ,then press <OK> button on
R/C as shown follow:
i)
Wait laser check to complete,press <stop> button to exit as
shown follow:
1 2 3 4 1 2
CAUTION!
This information is confi dential and may not be
distributed.Only a qualifi ed service person should
reprogram the Region Code.
j) If laser check fails press “
” <Home> button and repeat OPU
matching procedure.
8)DVD Region Code Change
a) In open mode, press “8” “6” “8” “9” “3” “1” on R/C,then input
desired number to change region code:
1 USA
2 EU
3 APAC
4 Australia ,NZ, Latam
5 Russia ,India
6 China
Summary of Contents for HTS3260/12
Page 10: ...2 3 2 3 MAIN UNIT REPAIR CHART REPAIR INSTRUCTIONS ...
Page 14: ...4 1 4 1 BLOCK DIAGRAM ...
Page 15: ...4 2 4 2 WIRING DIAGRAM V8 V7 V6 V2 V4 V5 V3 V1 ...
Page 40: ...9 10 9 10 CIRCUIT DIAGRAM nine A 1 2 3 1 2 3 HA500 A3 ...
Page 50: ...12 1 REVISION LIST Version 1 0 Initial release ...