HR8572 /A /D
DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- To open the appliance, first remove the 2 screws of the
control panel (
item 11
) then with a big screw driver
disconnect the 2 snap locks of panel and lower housing
(see drawing).
- The component configuration shown in the exploded view
may differ in case of specific versions. The components are
distinguished by means of code numbers.
- When the repair is finished, check whether all functions of
the appliance work properly.
- To (dis)assemble the appliance use TORX screw driver no
T15 (4822 395 10329), which is one of a set consisting of
T20, T15, TI0, T9, T8, T7 and T6 = 4822 395 50145.
- To connect the nozzle, the telescopic tube and the handle:
insert the narrowed section into the wider section while
turning it a little.
To disconnect: Pull while rotating. To adjust the telescopic
tube (
item 74
) to the required length, use the knob in the
direction of the arrow while sliding the top section of the
telescopic tube into or out of the lower section.
REPAIR INSTRUCTION
- The spare parts have been standardized as much as possible.
-
Item 6
, cotton dustbag, is used in those countries where
paper dustbags are not available.
- The cordwinder (
item 21)
is provided with a long cord-
winder spring; both long and short cords can be used in
combination with this spring.
- The cord winder spring must be tensioned to the maximum
level and then be rewound approx. 1.5 turn.
- Depending on the original cord, the spare cord must be
shortened to the length of the original cord.
- If the cord comes without AMP clamps, it can be soldered
onto the terminals.
- If the reel half spring unit is replaced, shaft
A
must be
lubricated with
silicone grease
(A). Do not apply any
silicone grease to or spill any grease on the terminals or
conductors.
- The assembly of accessories depends on the national
version.
- Adjusting the PCB on the motor to 220V, 60Hz.
1. Make sure that the potentiometer (
item 36
) is set at
min. position.
2. Adjust the potentiometer on the PCB
item 45
, on the
motor to 220V/60Hz to allow the motor to run
smoothly.
Please note: the standard setting of the spare PCB is
230V/50Hz.
There are open-circuit voltages on all wires.
M
MOTOR
POWER
MODULE
ROTARY
POTMETER
CORD WINDER
MAIN
SWITCH
2-7
Summary of Contents for HR8572
Page 4: ...HR8572 A D EXPLODEDVIEW 4 7 ...
Page 5: ...HR8572 A D EXPLODEDVIEW 5 7 ...
Page 7: ...HR8572 A D 7 7 ...