HD6596/50/G /51/G
6-18
Repair instruction
Descaling
Scale builds up inside the machine during use. It is essential to descale the SENSEO® coff ee machine when the CALC light
starts fl ashing. If the descaling procedure is not performed correctly, scale residue remains behind in the machine. This
causes scale to build up more quickly and may cause permanent and irreparable damage to the machine.
Use the correct descaling agent (HD7011, HD7012 only). It has been developed to ensure better machine performance and
operation. Never use a descaling agent based on mineral acids such as Sulphuric acid, Acetic acid (vinegar) or Hydrochloric
acid. These descaling agents may damage your SENSEO® coff ee machine.
For detailed instructions, please refer to the Directions For Use, chapter CALC.
Note:
HD659x the descaling routine has changed to 2x descale cycles and 2x flushing cycles.
Intensity select
The new PCBA (03-2018 onwards) has an extra feature onboard “Intensity select”, which need to be enabled for the
following type numbers (HD6592 & HD6596).
Intensity select how does that work:
•
Select the strong short coffee recipe by double tap on the 1-cups button for 1 cup of strong short coffee.
•
Press the 1-cup button once for one large mild cup of coffee.
•
Select the strong short coffee recipe by double tap on the 2-cups button for a double cup of strong short coffee.
•
Press the 2-cup button once for two large mild cups of coffee.
2x
2x