Architectural Decorative

  FS01

Page 2 of 2 

Vetro Pendant

Catalog No. FS01, 13W 4-Pin Twin Tube, 800 Lumens.

Catalog No. FS01Q, 13W 4-Pin Quad Tube, 900 Lumens.

Report No. 3108FR

54

41

27

14

60°

30°

0

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 74 74 74 74 69 69 58 58 49 49 36
1 64 60 56 52 55 48 46 40 37 33 23
2 57 50 44 40 46 37 38 31 31 25 17
3 51 43 37 32 39 29 33 24 26 20 13
4 46 37 31 26 34 24 28 20 23 16 10
5 42 33 26 22 30 20 25 17 20 14

8

6 39 29 23 18 27 17 22 14 18 12

7

7 36 26 20 16 24 15 20 12 16 10

6

8 33 24 18 14 22 13 18 11 15

9

5

9 31 22 16 12 20 11 17

9 14

8

4

10 29 20 14 11 18 10 15

8 13

7

4

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 16.0

Report No. 3105FR

Catalog No. IS01, 50W T-4, 950 Lumens.

60°

30°

0

158

119

79

40

1

Report No. 3101FR

CANDLEPOWER SUMMARY

Angle Mean CP Angle Mean CP

0

39

90

54

5

42

95

54

10

45

100

54

15

43

105

53

20

38

110

51

25

34

115

49

30

34

120

47

35

35

125

44

40

37

130

41

45

40

135

37

50

43

140

33

55

45

145

29

60

47

150

25

65

50

155

20

70

51

160

15

75

53

165

10

80

54

170

5

85

54

175

2

90

54

180

1

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

32.14

4

5.8

0-40

54.24

6.8

9.8

0-60

125.68

15.7

22.8

0-90

289.44

36.2

52.4

90-120

163.26

20.4

29.6

90-130

202.8

25.4

36.7

90-150

249.85

31.2

36.7

90-180

262.55

32.8

47.6

0-180

551.99

69

100

**  Efficiency = 69%  ** 

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

4.1

10-20

11.89

20-30

16.15

30-40

22.11

40-50

31.03

50-60

40.41

60-70

49.15

70-80

55.68

80-90

58.92

90-100

58.92

100-110

55.68

110-120

48.66

120-130

39.53

130-140

28.74

140-150

18.32

150-160

9.51

160-170

2.91

170-180

.29

CANDLEPOWER SUMMARY

Angle Mean CP Angle Mean CP

0

54

90

49

5

54

95

49

10

48

100

48

15

43

105

47

20

37

110

46

25

28

115

45

30

28

120

42

35

30

125

40

40

32

130

37

45

35

135

34

50

37

140

30

55

40

145

26

60

42

150

22

65

44

155

18

70

46

160

13

75

47

165

8

80

48

170

4

85

48

175

2

90

49

180

1

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

28.52

3.2

5.8

0-40

47.41

5.3

9.6

0-60

110.28

12.3

22.4

0-90

256.23

28.5

52

90-120

147.51

16.4

29.9

90-130

183.11

20.3

37.1

90-150

225.8

25.1

37.1

90-180

236.85

26.3

48

0-180

493.07

54.8

100

**  Efficiency = 54.8%  ** 

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

4.96

10-20

10.5

20-30

13.06

30-40

18.89

40-50

27.06

50-60

35.81

60-70

43.7

70-80

49.73

80-90

52.51

90-100

53.33

100-110

49.99

110-120

44.19

120-130

35.6

130-140

26.11

140-150

16.58

150-160

8.29

160-170

2.51

170-180

.25

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 59 59 59 59 55 55 46 46 39 39 28
1 51 47 44 41 43 38 36 32 30 26 18
2 45 40 35 31 36 29 30 24 24 20 13
3 41 34 29 25 31 23 26 19 21 16 10
4 37 30 24 20 27 19 22 16 18 13

8

5 34 26 21 17 24 16 20 13 16 11

6

6 31 23 18 15 21 13 18 11 14

9

5

7 28 21 16 13 19 12 16 10 13

8

5

8 26 19 14 11 17 10 14

9 12

7

4

9 25 17 13 10 16

9 13

8 11

6

4

10 23 16 11

9 14

8 12

7 10

5

3

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 14.0

CANDLEPOWER SUMMARY

Angle Mean CP Angle Mean CP

0

158

90

33

5

104

95

34

10

43

100

33

15

23

105

33

20

18

110

32

25

17

115

31

30

19

120

29

35

20

125

27

40

22

130

25

45

24

135

23

50

26

140

21

55

28

145

18

60

29

150

16

65

31

155

13

70

32

160

9

75

33

165

5

80

33

170

1

85

33

175

1

90

33

180

1

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

23.21

2.4

6.8

0-40

36.04

3.8

10.5

0-60

79.48

8.4

23.1

0-90

180.42

19

52.5

90-120

101.76

10.7

29.6

90-130

126.02

13.3

36.7

90-150

155.48

16.4

36.7

90-180

163.04

17.2

47.5

0-180

343.46

36.2

100

**  Efficiency = 36.2%  ** 

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

8.06

10-20

6.98

20-30

8.18

30-40

12.83

40-50

18.63

50-60

24.81

60-70

30.42

70-80

34.52

80-90

36.01

90-100

36.82

100-110

34.52

110-120

30.42

120-130

24.26

130-140

17.85

140-150

11.61

150-160

5.93

160-170

1.53

170-180

.1

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 39 39 39 39 36 36 31 31 26 26 19
1 34 31 29 27 29 25 24 21 20 18 12
2 30 26 23 21 24 19 20 16 16 13

9

3 27 23 19 17 21 15 17 13 14 11

7

4 25 20 16 14 18 13 15 11 12

9

5

5 22 18 14 12 16 11 13

9 11

7

5

6 21 16 12 10 14

9 12

8 10

6

4

7 19 14 11

9 13

8 11

7

9

6

3

8 18 13 10

8 12

7 10

6

8

5

3

9 16 12

9

7 11

6

9

5

7

4

3

10 15 11

8

6 10

6

8

5

7

4

2

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 50.0