Coil Upgrade:
Remove by de-soldering and upgrade the following coils to the new turns, with the same diameter on the PA
board.
Coil Original Turns
New Turns
Wire Size
Drill Size for winding coil
L101
2.5
3.5
0.63mm
L103
2.5
3.5
0.63mm
L104
2.5
3.5
0.63mm
L105
0.75 1.0
0.63mm
L106
No
change
L107
No
change
L108
8.5
10.5 0.80mm
L109
2.5
3.5
0.80mm
L110
1.0
1.5
0.80mm
L111
No
change
L112
No
change
L113
No
change
L114
2.5
0.80mm
L115
1.0
1.5
0.80mm
L116
2.5
3.5
0.80mm
L117
No
change
L118
6.5
0.80mm
L119
5.5
6.5
0.80mm
L120
4.5
5.5
0.80mm
L121
5.5
5.5
0.80mm
L122
5.0
0.63mm
Philips FM92E Conversion to 6 Meters: Version 3.9 Page