Départ. Technical support- CM640
PROCEDURE
COMPANY RESTRICTED
PHILIPS Consumer
Communications
Centre du Mans
Service Repair Support
VY-V-640-120-2
Page : 26 of 45
Language : EN
Date : 23/04/02
Ó
PHILIPS ELECTRONICS N.V. 1999
VY-V-640-
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
8.3.8
PCN Specification (1800 Mhz)
Test parameter
Channel
Level
Standard specifications
ÉMISSION
Phase error RMS
512, 700, 885
0,5,10
0 to 5 degree
Phase error Peak
0,5,10
-20 to +20 degree
Frequency Error
0,5,10
-180 Hz to + 180 Hz
Power Ramping
0,5,10
Mask
Modulation
0,5,10
Mask
Switching Transients
0,5,10
Mask
Timing Advance
0,5,10
+/- 1.00 bit
Power reading
Output Power
Level 0
30 +/- 2 dBm
Level 10
10 +/- 4.0 dBm
Level 15
0 +/- 5.0 dBm
RECEPTION
Rx Level
512, 700, 885
-102dbm
4 to 12
Rx Qual
-102dbm
0 to 1
Rx Level
512, 700, 885
-85dbm
21 to 29
Rx Qual
-85dbm
0
Rx Level
512, 700, 885
-60dbm
46 to 54
Rx Qual
-60dbm
0
TCH LOOP
SENSITIVITY
BER
512, 700, 885
-85dbm
0%
FER
512, 700, 885
-85dbm
0%
BER
512, 700, 885
-102dbm
2.44%
FER
512, 700, 885
-102dbm
0%
If a phone is out of the specifications, it must be sent to the Repair Center.