setting the fragrance level

 1 

 To set the fragrance level, turn the cartridge forwards (maximum emission) or backwards 

(minimum emission) (Fig. 1).

  

 Close the cartridge when you store the vacuum cleaner or do not want any fragrance to be 

emitted. Turn the cartridge backwards until the openings of the cartridge are no longer 

visible.

storage

 1 

 Switch off the appliance and remove the mains plug from the wall socket.

  

 Press the cord rewind button to rewind the mains cord (Fig. ).

  

 Put the appliance in upright position and insert the ridge on the nozzle into the slot to attach 

the nozzle to the appliance (Fig. 23).

  

 Always put the Tri-Active nozzle in the carpet setting when you store it. Also prevent the side 

brushes from becoming bent (Fig. 9).

Replacing/emptying the dustbag

Always unplug the appliance before you replace or empty the dustbag,

Replacing the paper dustbag

Replace the dustbag as soon as the dustbag-full indicator has changed colour permanently, i.e. 

even when the nozzle is not placed on the floor (Fig. 24).

 1 

 Pull at the release tab to open the dustbag compartment cover (Fig. 25).

  

 Lift the dustbag holder out of the appliance (Fig. 6).

Make sure you hold the dustbag upright when you lift it out of the appliance.

  

 Pull at the cardboard tag to remove the full dustbag from the holder (Fig. 27).

When you do this, the dustbag is sealed automatically.

  

 Slide the cardboard front of the new dustbag into the two grooves of the dustbag holder as 

far as possible (Fig. 28).

 5 

 Reinsert the dustbag holder into the vacuum cleaner (Fig. 29).

If you have not inserted a dustbag, you cannot close the dustbag compartment cover.

Cleaning/replacing filters

Always unplug the appliance before you clean or replace the filters.

Cleaning the Motor Protection Filter

Clean the Permanent Motor Protection Filter every time you replace the dustbag. 

 1 

 Remove the dustbag holder with the dustbag (Fig. 26).

  

 Take the Motor Protection Filter holder out of the appliance and shake it over a 

dustbin (Fig. 0).

  

 Put the clean filter back into the filter holder. Fit the two lugs of the filter holder behind the 

ridge at the bottom to ensure that it fits properly at the top. Then press the filter holder 

home (‘click’) (Fig. 1).

  

 Place the dustbag holder with the dustbag back into the appliance.

-

,

English

9

Summary of Contents for FC9060

Page 1: ...FC9066 FC9060 ...

Page 2: ... ...

Page 3: ... 1 ...

Page 4: ... ...

Page 5: ...FC9066 FC9060 English 6 简体中文 12 ...

Page 6: ... the appliance and save it for future reference Check if the voltage indicated on the appliance corresponds to the local mains voltage before you connect the appliance Do not use the appliance if the plug the cord or the appliance itself is damaged If the mains cord is damaged you must have it replaced by Philips a service centre authorised by Philips or similarly qualified persons in order to avo...

Page 7: ...hole click Fig 4 2 To disconnect the tubes from each other and from the handgrip press the spring loaded lock button and pull the part with the lock button out of the part with the hole Use the same method to connect and disconnect the nozzles 3 Adjust the tube to the length you find most comfortable during vacuum cleaning Fig 5 Tri Active nozzle TheTri Active nozzle is a multi purpose nozzle for ...

Page 8: ... tube If you want to pause for a moment insert the ridge on the nozzle into the parking slot to park the tube in a convenient position Fig 17 Active Fragrance Control The scent granules have been specially developed for use in your Philips vacuum cleaner Only use the Philips s fresh scent granules in your vacuum cleaner If the vacuum cleaner is equipped with Active Fragrance Control keep it out of...

Page 9: ...release tab to open the dustbag compartment cover Fig 25 2 Lift the dustbag holder out of the appliance Fig 26 Make sure you hold the dustbag upright when you lift it out of the appliance 3 Pull at the cardboard tag to remove the full dustbag from the holder Fig 27 When you do this the dustbag is sealed automatically 4 Slide the cardboard front of the new dustbag into the two grooves of the dustba...

Page 10: ...ning replacement items If you have any difficulties obtaining replacement items for this appliance please contact the Philips Customer Care Centre in your country or consult the worldwide guarantee leaflet Dustbags Philips Classic s bag paper dustbags are available under type number FC8021 Philips Clinic s bag high filtration dustbags are available under type number FC8022 Filters Super Clean Air ...

Page 11: ...dustbag or empty the reusable dustbag Perhaps the filters are dirty Replace the filters The nozzle tube or hose may be blocked up To remove the obstruction disconnect the blocked up item and connect it as far as possible the other way around Switch on the vacuum cleaner to force the air through the blocked up item in opposite direction Fig 36 English 11 ...

Page 12: ... FC9066 19 洁旋风吸嘴纤维软垫 20 全方位清洁吸尘嘴 21 放置 存放夹片 22 地毯 硬地面转换开关 23 边刷 24 附件夹 仅限 FC9060 25 伸缩管 26 过滤器栅格 打开状态 27 电源插头 28 摆放固定槽 29 HEPA 高效能过滤网 仅限 FC9066 30 高效能过滤网 仅限 FC9060 31 转轮 32 插槽 33 型号牌 注意事项 使用产品之前 请仔细阅读本用户手册 并妥善保管以供日后参 考 在将产品连接电源之前 请先检查产品所标电压与当地的供电电 压是否相符 如果插头 电源线或产品本身受损 请勿再使用本产品 如果电源软线损坏 为避免危险 必须由制造厂或其维修部或类 似的专职人员来更换 本产品不可由肢体不健全 感觉或精神上有障碍或缺乏相关经验 和知识的人 包括儿童 使用 除非有负责他们安全的人员对他 们使用本产品进行监督或提供相关指导 简体中文 ...

Page 13: ...产品符合关于电磁场 EMF 的相关标准 据目前的科学证明 如果正确使用并 按照本用户手册中的说明进行操作 本产品是安全的 使用准备 连接附件 软管 要连接软管 请将其推入到产品中 会听到咔哒一声 图 2 要卸下软管 请按下按钮并将软管从产品拉出 图 3 伸缩管 1 将硬管互相连结或与握把连结时 按下弯管上的弹簧锁按钮 然后将带有锁定钮的部 分插入带有小孔的部分 将锁定钮对准 牢固地插入小孔内 听到咔哒一声 图 4 2 要将硬管互相分离或与握把分离时 请按下弹簧锁按钮 将带有按钮的部分从带有小 孔的部分拉出 请通过同样的方法来连接及拆卸吸嘴 3 将硬管调整到吸尘过程中感觉最舒适的长度 图 5 全方位清洁吸尘嘴 Tri Active 吸尘嘴是用于清洁地毯和硬质地板的一种多用途吸尘嘴 吸尘嘴侧面的侧毛刷可以清洁更多灰尘和污垢 让您可以沿家具和其他障碍物边缘进 行清洁 图 6 吸尘嘴正面的开口允许...

Page 14: ...即可 图 12 附件支架上可同时存放两个附件 缝隙吸嘴和小号吸嘴 图 13 请注意小号吸嘴必须放在附件存放架上的特定方向 缝隙吸嘴和小号毛刷 图 14 使用本产品 吸尘 1 将电源线从吸尘器中拉出 并将电源插头插入插座 2 用脚推动产品上的 on off 开 关 按钮来开启机器 图 15 调整吸力 吸尘过程中 您可以使用产品顶端的吸力控制旋钮来调节吸力强度 将旋钮调到MAX时 是最大吸力 图 16 对于特别脏的地毯和硬地板 可用最大吸力吸尘 将旋钮调到 MIN 时 是最小吸力 清洁门帘 台布或其他物品时 可用最小吸力 放置硬管 如要暂停使用吸尘器 可通过将吸嘴上的夹片插入摆放固定槽以将硬管放妥 图 17 活性香气控制 特别研制的香味颗粒专用于您的飞利浦真空吸尘器 只能使用飞利浦 s fresh 香味颗 粒 如果吸尘器装备了活性香气控制 那么无论在使用过程中还是使用 后 都不要让儿童接触到它...

Page 15: ...它发出任何香味时 请关闭香味颗粒筒 将香味颗粒筒向 后旋转 直到看不见筒口为止 存放 1 关闭吸尘器的电源 从插座中拔下电源插头 2 按下电源线回卷按钮将电线回卷到吸尘器中 图 22 3 将产品竖立存放并将吸嘴安装到产品上 而后将吸嘴上的夹片插入产品背面的插槽 中 图 23 4 存放前 必须先将全方位清洁吸嘴处于地毯设置 以避免侧面的毛刷被弯曲 图 9 更换 清空集尘袋 更换或清空集尘袋前 切记拔下电器插头 更换纸质集尘袋 在集尘袋已满指示灯的颜色改变时 在吸嘴没有紧贴地板的情况下 请立即更换集 尘袋 图 24 1 按释放钮并将机盖向上拉 可打开集尘袋仓盖 图 25 2 取出集尘袋固定架 图 26 将集尘袋拉出吸尘器时 请确保以向上方向拉出集尘袋 3 拉起纸板片将装满灰尘的集尘袋取掉 图 27 这时 集尘袋会自动封闭 4 将新集尘袋前面的纸板片套入集尘袋固定架上的两个狭槽中 尽量向下按 图...

Page 16: ...取出旧的滤网 图 33 3 将新的滤网插入吸尘器 4 关闭过滤器栅格 推下面的角 直到卡住其位置 图 34 更换 HEPA 高效能过滤网 如果不安装高效能过滤网 本产品还可以安装特殊的 HEPA 高效能过滤网 这种滤网可以 从排出空气中过滤 99 5 的最小为 0 0003 毫米的颗粒 这不仅能过滤正常的室内灰尘 而且还能过滤显微级别的寄生虫和它们的排泄物 众所周知 这些排泄物能引起呼吸道过 敏 每 6 个月更换一次 HEPA 高效能过滤网 1 HEPA 高效能过滤网的更换方法与高效能过滤网的更换方法一样 订购附件或替代品 如果您在购买本产品的附件或替换品时遇到任何困难 请和您所在国家的飞利浦客户服务 中心联系 或参阅全球保证书 集尘袋 飞利浦 Classic s bag 纸质集尘袋的型号是 FC8021 飞利浦 Clinic s bag 高过滤集尘袋的型号是 FC8022 过滤网 高效能...

Page 17: ...贵 国没有飞利浦顾客服务中心 请与当地的飞利浦经销商或与飞利浦家庭小电器的维修中心 联系 环保 弃置产品时 请不要将其与一般生活垃圾堆放在一起 应将其交给官方指定的回收中 心 这样做有利于环保 图 35 故障种类和处理方法 1 吸力不足 确保吸力控制旋钮在最大位置 可能集尘袋已满 更换纸质集尘袋或清空循环使用集尘袋 可能过滤网脏了 请更换过滤网 检查吸嘴 硬管 软管是否被阻塞 要清除阻塞物 请将阻塞的部分拆下 并将它反 向连接 尽可能离远一些 打开吸尘器的电源 强迫气流反方向通过阻塞的部 位 图 36 简体中文 2007 04 26 FC9060 FC9066 1600W 1600W ...

Page 18: ...18 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 ...

Page 19: ...19 22 23 24 25 26 27 28 29 1 2 30 31 32 33 34 35 36 ...

Page 20: ...4222 003 3361 2 ...

Reviews: