background image

INSTALLATION INSTRUCTIONS 
F Series Floodlight 

 

 
 
 
 
 

© 2016  Philips Lighting Holding B.V.  All rights reserved. 

www.philips.com/luminaires

 

Part Number 443561002550 Rev.  F 

Page 

6

 of 

7

 

NEC  and  local  codes.  Follow  wiring 
instruction on ballast. 

IMPORTANT: 

If 

high 

pressure 

sodium  remote  ballast  is  used  make 
sure  the  ballast  is  installed  within  the 
distance  limitations  published  by  the 
ballast manufacturer.  

 

 
PCM-1 Photocell Receptacle Only 

Remove  1/2”  pipe  plug  from  the  ballast 
mastfitter 

base. 

Thread 

the 

1/2” 

photocell  receptacle  into  the  mastfitter 
base,  tighten  securely.  Check  to  see  that 
the  photocell  (provided  by  user)  is  of 
proper  voltage  and  wattage.  Wire  in 
accordance to wiring diagram.  
(See

 FIGURE 15). 

 

WG-10 or WG-4 Wireguard 

Attach  wireguard  to  cored  holes  on  top 
and bottom of fixture with thread cutting 
screws  provided  in  kit  (see 

FIGURE 

16

).  

 

MF-1  Mastfitter  for  Less  Ballast 
Models 

Allows  fixture  head  to  be  remote 
mounted on a vertical 2-3/8” OD tenon x 
4-1/2” tall. Attach fixture mounting arms 
to  the  MF-1  using  hardware  as  covered 
in  steps  4  and  5  of  fixture  assembly. 
Remove  pipe  plug  from  MF-1  and  route 
S.O.  cord  through  a  watertight  cable 
connector (provided by user) for internal 
wiring  to  the  remote  ballast.  Or,  wiring 
can  be  external  to  an  appropriate 
junction  box  or  similar  device  (See 

FIGURE 17

). 

 

HV-1  Trunion  Base  for  Less  Ballast 
Models 

Can  be  mounted  to  any  suitable 
horizontal  or  vertical  surface  suited  for 
the  purpose.  Calibrate  in  10°  increments 
(0°-90°) for horizontal adjustment. There 
are three mounting holes, 7/16” nominal 
diameter  for  3/8”  mounting  bolts 
(provided by user) for mounting the 
HV-1 attach fixture mounting arms to the 
HV-1 using hardware as covered in steps 
4  and  5  of  fixture  assembly  (See 

FIGURE 18

). 

 

WB-1 Wall Mounting Bracket  

For  mounting  floodlight  with  ballast  or 
less  ballast  models  to  a  flat  vertical 
surface  only.  There  are  four  9/16” 
nominal mounting holes in the back plate 
for 1/2” mounting bolts (provided  
 
 
 
by  user).  Wiring  of  fixture  can  be  done 
internally 

(see 

wiring 

instructions) 

through  the  bracket  for  applications 
where  the  wiring  box  is  flush  mounted. 
Or,  can  be  wired  externally  to  an 
appropriate  junction  box  or  similar 
device. (See

 FIGURE 19). 

 
 

WG-10, WG-4 

AL-10, AL-4 

Summary of Contents for F Series

Page 1: ...will VOID THE WARRANTY GENERAL Upon receipt inspect for any freight damage which should be brought to the attention of the delivering carrier See Damage and Shortage Claims for proper steps in filing claims with the carrier Compare the catalog description listed on the packing slip with the label on the carton to assure you have received the correct material This floodlight is designed for outdoor...

Page 2: ...cket housing gasket is seated properly and then tighten the screws securely E OR ED SHAPED LAMPS This lamp shape is primarily found in 400 watt size lamps The BT stabilux collar must be removed before installing an E or ED shaped lamp This is accomplished by compressing the BT split collar by hand and removing from the fixture Inside the stabilux cavity of the fixture there is a E lamp stabilux fo...

Page 3: ...nnector body Slide cable connector nut up the S O cord then slide the rubber grommet approximately 3 up the S O cord Insert S O cord into cable connector body then attach and securely tighten the cable connector nut to 15 ft lbs STEP 7 Remove inspection plate and gasket from back of mastfitter by removing the two screws See FIGURE 5 Mount fixture ballast assembly to 2 3 8 OD vertical pipe tenon by...

Page 4: ...dlight Follow steps 1 through 3 above Next attach the U bracket to the ballast mastfitter as shown in FIGURE 6 CAUTION the two holes in the bracket for the 3 4 long bolts must be toward the top as shown in FIG 6 Mount fixture to the U bracket and attach the three 3 8 16 mounting bolts and lock washers IMPORTANT The 1 2 long bolt is centered over the fixture flange and to the bottom of the mount Ti...

Page 5: ...osite fixture lens There are five 9 16 mounting holes for securing the PX 1 to the cross member three of which can be utilized without bolt interference These are the two on top and the lower horizontal hole in the back plate As a minimum these three holes must be utilized Mounting hardware 1 2 bolts provided by user See FIGURE 10 PM Wood Pole Mounting Brackets Aluminum wood pole mounts with verti...

Page 6: ...MF 1 using hardware as covered in steps 4 and 5 of fixture assembly Remove pipe plug from MF 1 and route S O cord through a watertight cable connector provided by user for internal wiring to the remote ballast Or wiring can be external to an appropriate junction box or similar device See FIGURE 17 HV 1 Trunion Base for Less Ballast Models Can be mounted to any suitable horizontal or vertical surfa...

Page 7: ...om and back for 3 4 NPT conduit Gasket provided for sealing box to the WB 1 Mounting hardware 1 2 mounting bolts provided by user The WB 5 box is supported by the same bolts used to support the WB 1 and need to be long enough to secure both the WB 1 and box to the wall The box straddles the four mounting bolts See FIGURE 20 TH 1 Hanger for Less Ballast Models For mounting floodlights on standard l...