INSTALLATION
A drill and a screwdriver are needed for installation.
Select a location for the unit based on the coverage
angles shown in FIGURE 3.
180°
12m
110°
UNIT(m)
COVERAGE ANGLES
FIGURE 3
WIRING INSTRUCTION
(1) Switch off the power source.
(2) Detach the wall box by unscrewing the screw
adjacent to the control knobs (retain the screw for
later use). (FIGURE 4)
FIGURE 4
(3) Use a screwdriver to break a small hole on the cable
gasket, enabling the power cord to enter the wall
box.
(4) Route the power cord through the cable gasket.
(5) Determine the proper location to mount the light.
Use the wall box as a template to mark the fixing
holes on the wall. Drill the holes and insert the
plastic wall plugs supplied. Fix the wall box using
two screws provided. (FIGURE 5)
m
5
.
3
8
m
FIGURE 5
(6) Strip approximately 6-8mm insulating part of the
wires from the power cord.
(7) Connect the BROWN wire (Live wire) to the terminal
block “L” mark.
Connect the BLUE wire (Neutral wire) to the
terminal block “N” mark. (FIGURE 6)
TO LAMP
LIVE
NEUTRAL
AC POWER
BROWN
BLUE
FIGURE 6
(8) Replace the unit to the wall box by fastening the
screw retained.
ADJUST ANGLE
The lights can be adjusted up to 45° leftward and
rightward respectively; the PIR sensor can be adjusted
90° leftward and 90° rightward. (FIGURE 7a)