1
8
Design-in Guide - EasyAir SNS210
MC
August
202
1
To ensure that a luminaire has been assembled correctly
i.e. the wiring of the EasyAir SNS210 MC sensor to Xitanium
SR driver is correct; a visible check can be made.
The luminaire on power up dims up to 30% of maximum
light output in the 1st second followed by dimming up to
100% in the next second.
This behaviour is only visible in non-commissioned
devices i.e. once grouped using Philips MasterConnect
app, this behaviour will cease to exist.
Luminaire Production Test