4-1
Spindle motor does not move
Yes
Yes
No
No
No
No
Yes
Check whether “RFA5V”
(+5V) voltage is normal.
Correct connection
Check the RFA5V power
supply
Check/Replace Q7
ǃ
Q8.
Check/ Replace U1.
Have no to focus
1. Check U1 42pin FOO signals
2. If there are F+, F-, T+ and T-
signals output from U2.
Check/Replace the loader
Yes
Yes
No
Go
Check whether laser voltage
(2V for VCD & 2.2V for DVD)
on Collector of Q7 and Q8
Check the FFC connection
between 24P and the loader.
1. Whether voltage on pin 44
of U1 varies between 0 and
3.3V (3.3V for VCD and 0V for
DVD),
Trouble shooting chart
Motor no move
Summary of Contents for DVP 1013
Page 21: ...6 2 6 2 Front Board Print Layout Bottom Side for DVP1013 37 ...
Page 23: ...6 4 6 4 Power Board Print Layout Bottom Side for DVP1013 37 ...
Page 28: ...Main Board Print Layout Top Side 6 9 6 9 for DVP1013 37 ...
Page 29: ...6 10 6 10 Main Board Print Layout Bottom Side for DVP1013 37 ...
Page 32: ...REVISION LIST Version 1 0 Initial release 8 1 ...