Diagnostic Software
5.
121202
Reading the data from the UART failed
Example
DS:> 1212 2
121200: The HEX value that was read is: 0x50 0xD1 0x00
Test OK @
Nucleus Name
DS_SYS_VideoLoopThroughStart
Nucleus Number
1213
Description
The video signal, which is conform the user input, is routed from the input to the output.
The input is set using the proper nucleus to route the signal on the board(s). All outputs
are enabled.
Technical
-
Decode the videosignal: PAL / NTSC and Y/C, RGB, CVBS,YUV
-
Initialise the Video Input Processor and check for valid signal
-
Initialise the Video Front End and start capturing frames to memory
-
Initialise the SYNC module
-
Initialise the Video Post Processing and retrieve frames from memory
-
Initialise the mixer
-
Initialise the DENC module
-
Route the signal to all outputs
Execution Time
Less than 1 second, but stays running.
User Input
<vipInput> <VideoOutput> <VideoStandard>
1.
vipInput (CVBS, YC, YUV, RGB, 1 to 9(see table below)).
LECO Premier specific
User input
Video input
Data path to VIP
1
RGB
SCART aux RGB in
2
YC
SCART aux Y/C in
3
CVBS
SCART aux CVBS
4
CVBS
Tuner
5
YC
Front Y/C
6
CVBS
Front CVBS
7
CVBS
SCART TV CVBS
8
YC
CE mode Y/C in
9
CVBS
CE mode CVBS in
10
XPORT
XPORT
2. VideoOutput (YUV, RGB).
3. VideoStandard (PAL, NTSC).
Error
Number
Description
121300
Video LoopthroughStart succeeded
121301
User input is not valid.
121302
Initialisation of the VIP failed.
121303
Unable to stop the loop through before restarting.
121304
Video Signal on the input is not a valid signal.
121305
Initialisation of the VFE failed.
121306
The digital board hardware information is corrupt
Example
DS:> 1213 CVBS RGB PAL
121300:
Test OK @
Nucleus Name
DS_SYS_VideoLoopThroughStop
Nucleus Number
1214
Description
Stop routing the video input to all the outputs.
Technical
Stop the DENC and the Video Front End
Execution Time
Less than 1 second.
User Input
-
Error
Number
Description
121400
VideoLoopthroughStop succeeded
121401
DENC module on Codec failed.
Example
DS:> 1214
121400:
Test OK @
Nucleus Name
DS_SYS_VideoLoop
Nucleus Number
1215