Diagnostic Software
5.
Error
Number
Description
120400
Getting the Diagnostics software version succeeded
120401
Getting the Diagnostics software version failed
Example
DS:> 1204
120400: Software Diagnostics Version = 0001
Test OK @
Nucleus Name
DS_SYS_EepromUpload
Nucleus Number
1205
Description
Upload the contents of the NVRAM on the analogue board or the digital board to the
service PC, by using the X-modem protocol
Technical
-
Decode the user input
-
Determine whether to upload the analogue board or digital board NVRAM
-
Start uploading using the XMODEM protocol
-
Determine whether all was uploaded OK
Execution Time
Depends on the chosen NVRAM and the User.
User Input
Choose one of the following parameters for the nucleus:
1.
Upload the contents of the NVRAM of the digital board
2.
Upload the contents of the NVRAM of the analogue board
Choose in the terminal on the control PC -
>
transfer -> receive file
.
Select
X-modem
protocol. Then click
receive
in the dialogue and fill in the file name
in which you want to store the data.
Error
Number
Description
120500
Download succeeded.
120501
User input is not valid.
120502
Something went wrong while copying the data from
NVRAM to SDRAM .
120503
Something went wrong while transferring the data.
120504
User cancelled the upload.
Example
DS:> 1205 1
120500:
Test OK @
Nucleus Name
DS_SYS_EepromDownload
Nucleus Number
1206
Description
Download a file with the contents of the NVRAM for the analogue board or the digital
board from the service PC to the recorder, by using the X-modem protocol
Technical
-
Decode the user input and determine what EEPROM to fill: digital / analogue
-
Store the downloaded (using XMODEM) bytes in SDRAM first
-
Then copy these contents into the EEPROM after verification
Execution Time
Depends on the chosen NVRAM and the User.
User Input
Choose one of the following parameters for the nucleus:
1.
Download the contents of the NVRAM of the digital board
2.
Download the contents of the NVRAM of the analogue board
Choose in the terminal of the control
PC -> transfer -> send file
.
Select
X-modem
protocol. Then choose a file with the Browse button in the dialogue
and click on
send
.
Error
Number
Description
120600
Download succeeded
120601
The write to NVRAM failed.
120602
Timeout. Too many retries.
120603
A file was sent with a wrong header.
120604
User cancelled the download.
120605
User input is not valid.
120606
Unknown Error
Example
DS:> 1206 1
120600:
Test OK @
Nucleus Name
DS_SYS_DvIdNumberSet
Nucleus Number
1207
Description
Set the IEEE 1394 unique ID
Technical
-
Decode the user input
-
Store the id into NVRAM
-
Validate the segment of storage by updating the checksum
Execution Time
Less than 1 second.