EN 14
3139 785 31150
Firmware Upgrading & Diagnostic Software
5.
5.3
Player Script Interface
5.3.1
5.4
Menu and Command Mode Interface
5.4.1
Nuclei Numeration
Each nucleus has a unique number of four digits. This number
is the input of the command mode.
Figure 5-3
Group number Group name
0
Scripts
1
Codec (e.g. Chrysalis, Leco)
2
Boot EEPROM
3
NVRAM
4
SDRAM
5
Flash
6
Video Input Processor
7
DVIO
8
Progressive Scan
9
Basic Engine
10*
Display and Control Board
11*
Analogue Board
12
System
13*
Electronic Program Guide Board
14*
PCMCIA
[ XX YY
]
Nucleus number
Nucleus group number
CL 06532152_012.eps
051200
5.4.3
Command Mode Interface
Set-Up Physical Interface Components
Hardware required:
•
Service PC
•
one free COM port on the Service PC
•
special cable to connect DVD recorder to Service PC
The service PC must have a terminal emulation program (e.g.
Hyperterminal) installed and must have a free COM port (e.g.
COM1). Activate the terminal emulation program and check
that the port settings for the free COM port are: 19200 bps, 8
data bits, no parity, 1 stop bit and no flow control. The free COM
port must be connected via a special cable to the RS232 port
of the DVD recorder. This special cable will also connect the
test pin, which is available on the connector, to ground (i.e.
activate test pin).
Code number of PC interface cable: 3122 785 90017
Activation of Diagnostic Software
1.
Pull the mains cord from the recorder and reconnect it
again (reboot).
2.
The next welcome message will appear on the PC:
Welcome screen D&S program
Figure 5-5
Now, the prompt 'DS:>' will appear. The diagnostic software is
now ready to receive commands. The commands that can be
given are the numbers of the nuclei. If you see above shown
screen, continue with paragraph 'Nuclei Codes'.
5.4.2
Error Handling
Each nucleus returns an error code. This code contains six
numerals, which means:
Figure 5-4
The nucleus group numbers and nucleus numbers are the
same as above.
[ XX YY ZZ ]
Error code
Nucleus number
Nucleus group number
CL 06532152_013.eps
051200
15*
HDMI
16
Analogue Slave Processor
17
Analogue Board EEPROM
18
Video Matrix
19
Audio Matrix
20
Front End
21
Hard Disk
22*
Di
23*
USB
gital Terrestrial Tuner Module
* Not applicable for DVDR3300H, DVDR3330H and
DVDR5330H
Ranges
If you want that the recorder starts up in Virgin mode, follow this
procedure:
•
Unplug the recorder
•
plug the recorder again while you keep the STAND BY/ON
key pressed
•
the set starts up in Virgin mode.
Virgin mode