TECHNICAL DATA
(Subject to alteration)
0
Power output acc. to FTC
at 8 ohm load
(20-20.000 Hz, D
<
0.03%): 75
W continuous sine wave
at 4 ohm load
(20-20.000 Hz, D
<
0.05%) : 90 W continuous sine wave
0
Power output acc. to IEC
at 8 ohm load
(63-12.500 Hz, D
<
0.3%): 80 W continuous sine wave
0
Power output acc. to DIN
(1 kHz, D <0.7%)
at 8 ohm load: 85 W continuous sine wave
at 4 ohm load: 115 W continuous sine wave
at 2 ohm load: 140 W continuous sine wave
0
IHF music power
at 8 ohm load: 95 W
at 4 ohm load: 140
W
at 2 ohm load: 160 W
Harmonic distortion (1 kHz)
:
0.0I
%
Intermodulation distortion: 0.03%
0
Power bandwidth ( -
3 dB)
:
10-30.000 Hz
0
Frequency response: 20-20.000 Hz
0.5 dB
0
S
/
N ratio: 90 dB (weighted)
0
Channel separation (1 kHz) : 70 dB
0
Damping factor at 8 ohms: 80
0
Input sensitivity:
Phono MC: 0.25 mV
/
150 ohm
Phono MM: 2,5 mV
/
47 kohm
Compact Disc: 150 mV
/
20 kohm
Tuner: 150 mV
/
20 kohm
Aux 1
:
150 mV
/
20 kohm
Aux 2: 150 mV
/
20 kohm
Tape 1
:
150 mV
/
20 kohm
DAT
/
Tape 2 : 150 mV
/
20 ko h m
Compact Disc optical: 1
x
Toslink
Compact Disc: 0.5 V p-p
/
75 Ohm
DBS
/
Aux.: 0.5 V p-p
/
75 Ohm
DAT
/
Play
/
Rec: 0.5 V p-p
/
75 Ohm
0
Outputs:
DAT
/
Tape
:
150 mV
/
550 ohm
2
x
2 loudspeakers: 4-8 ohm
Headphones: 8-1000 ohm
Tone control:
bass:
+
8 dB to - 8 dB at 100 Hz
treble:
+
8 dB to - 8 dB at 10 kHz
0
Loudness: + 6 dB at 100 Hz, + 4 dB at 10 kHz
0
Balance control: 0-co dB
0
Power consumption: 330 W
This product complies with the radio interference requirements
as laid down in EC (European Community) regulations.
Important note for users
in U.K.:
The U.K.-version is not fitted with a mains plug
When fitting a mains plug to the mains lead proceed as follows: The wires in the mains lead
are coloured with the following code:
BLUE= NEUTRAL,
BROWN
=
LIVE.
As thesecolours may not correspond with the colour markings identifying the terminals in your
plug proceed as follows: The Brown wire must be connected to the terminal which is marked
with the letter L or coloured Red.
The Blue wire must be connected to the terminal which is marked with the letter N or coloured
Black.
Note: This apparatus must be protected by a 3 Amp Fuse if a
13
Amp plug
is used or, if any
other type of plug is used, by a 5 Amp Fuse either in the plug or adapter or at the distribution
board. If in doubt consult a qualified electric
i
an.