Philips ColorBurst 6 Product Manual Download Page 10

ColorBurst 6    Product Guide

10

 

E

 If installing in a wet or damp location, 

you must mount Luminaires to outdoor-

rated junction boxes, as described below.

E

 For complete instructions on how 

to wire the power / data supply, refer 

to the specific power / data supply’s 

Installation Guide or Specification Sheet. 

For sample wiring diagrams, visit www.

philipscolorkinetics.com/support/wiring/

ls_prod.html/

Start the Installation 

1.  Install all power / data supplies, including any interfaces with controllers. Power 

/ data supplies and external controllers send power and control signals to the 

Luminaires over a single 3-conductor cable. 

2.  Ensure that the number of free power / data supply power ports is adequate.
3.  Verify that all additional supporting equipment (switches, controllers) is in place.
4.  Ensure that all additional parts and tools are available, including:

•  The included 8-32 screws for indoor junction box installations, the included 

10-24 stainless steel screws for outdoor installations, or the included M-4 

screws if using the Mounting Base

•  The included 3/32 in hex key wrench
•  One Mounting Base per Luminaire, or one 102 mm (4 in) round US electrical 

junction box per Luminaire, rated for your application, with 89 mm (3.5 in) 

center-to-center screw holes for attaching the Luminaire’s base. (Refer to 

the junction box manufacturer’s literature for additional items required for 

mounting or sealing.)

•  Medium wire nuts
•  If mounting to a surface using the Mounting Base, #8 screws, suitable for the 

mounting surface, and lock washers

•  If installing to a junction box, or if extending the native power / data cable 

included with the Mounting Base, 18 AWG, 3-conductor stranded copper wire 

as required

•  Conduit as required
•  If installing in a wet or damp location, the included junction box gasket or 

Mounting Base gasket, and contractor-grade room temperature vulcanizing 

(RTV) silicone sealant as required

Install the Luminaires 

ColorBurst 6 Luminaires can be used freestanding with the Mounting Base, or they 

can be mounted to a wall, ceiling, or other suitable surface using the Mounting Base 

or a  junction box suitable for your application. In wet or damp locations, ensure that 

all junction boxes are suitable for the environment and are sealed. 

Mounting ColorBurst 6 to a Junction Box

ColorBurst 6 Luminaires are designed for mounting in a 102 mm (4 in) round US 

electrical junction box, rated for your application, with 89 mm (3.5 in) center-to-

center screw holes for attaching the Luminaire’s base. If installing in a wet or damp 

location, mount Luminaires to outdoor-rated junction boxes and seal them with 

contractor-grade room temperature vulcanizing (RTV) silicone sealant.

1.  Mount junction boxes in accordance with the lighting design plan.
2.  Pull 18 AWG, 3-conductor stranded copper wire from the junction box to the 

power / data supply. The maximum cable for an individual Luminaire is 45.7 m (150 

ft). The total cable length for each power / data supply cannot exceed 121.9 m 

(400 ft). 

3.  If installing in a wet or damp location, run the wire leads from the ColoBurst 6 

Luminaire through the included junction box gasket.

4.  Trim the Luminaire’s 152 mm (6 in) wire leads as necessary, then connect the wire 

leads to the junction box using medium wire nuts. Connect red to 24 VDC, white 

to data, and black to common, and neatly tuck wires into the junction box.

Included with the ColorBurst 6 

Luminaire

ColorBurst 6 Luminaire with accessory attachment ring
Accessory attachment spring
(4) 8-32 screws for installing to junction box indoors
(4) 10-24 stainless steel screws for installing to junction box 

outdoors
(4) color-matched screw caps
3/32 in hex key wrench
Junction box gasket
Installation Instructions

Summary of Contents for ColorBurst 6

Page 1: ...ColorBurst 6 The original architectural LED spotlight with intelligent color light ...

Page 2: ...le range of light positioning Full range of accessories Designed specifically for ColorBurst accessories provide additional options for controlling and dispersing light Top hats half top hats egg crate louvers barn doors and glass spread lenses attach easily to an integrated accessory attachment ring on the ColorBurst 6 housing Versatile mounting options ColorBurst 6 mounts to standard junction bo...

Page 3: ...open and inviting light show colors were designed to dynamically interact with the changing climate of upstate New York displaying warm colors during the cold winter months cool colors in the summer greens in the spring and orange colors in the fall The library uses a variety of Philips color changing LED lighting Luminaires throughout to lend color to computer hubs and work areas for example Colo...

Page 4: ...1 10 98 1 11 1 08 1 06 96 1 08 1 05 1 02 95 1 06 1 02 99 93 1 04 99 96 91 1 02 97 94 90 1 00 96 92 89 99 94 91 88 97 93 90 87 96 91 88 86 50 30 20 1 11 1 11 1 11 1 08 1 07 1 06 1 05 1 03 1 01 1 02 1 00 98 1 00 97 96 98 95 93 96 93 91 95 92 90 93 90 88 92 89 87 91 88 86 50 30 20 1 06 1 06 1 06 1 04 1 03 1 03 1 02 1 01 99 1 00 98 97 98 96 94 97 94 93 95 93 91 94 91 89 92 90 88 91 89 87 90 88 86 50 3...

Page 5: ...80 76 89 81 76 72 86 78 73 69 83 75 70 67 80 72 68 64 70 50 30 0 1 16 1 16 1 16 1 00 1 12 1 09 1 07 95 1 07 1 03 1 00 90 1 02 97 93 85 98 92 88 81 95 88 83 77 91 84 79 74 88 81 76 71 85 77 73 68 82 75 70 66 80 72 67 64 50 30 20 1 11 1 11 1 11 1 05 1 04 1 02 1 00 97 95 95 91 88 90 86 83 86 82 79 83 78 75 79 75 72 76 72 69 74 69 66 71 67 64 50 30 20 1 06 1 06 1 06 1 02 1 00 99 97 95 93 92 89 87 88 8...

Page 6: ...a cable with Mounting Base Temperature Ranges 40 to 50 C 40 to 122 F Operating 20 to 50 C 4 to 122 F Startup 40 to 80 C 40 to 176 F Storage Humidity 0 to 95 non condensing Maximum Luminaires Per Power Data Supply PDS 150e 24V 6 3 per port PDS 60 24V 2 1 per port Certification and Safety Certification UL cUL CE PSE C Tick SAA Environment Dry Damp Wet Location IP66 30 mm 1 2 in Ø11 4 mm 4 5 in 64 mm...

Page 7: ...ps 12NC ColorBurst 6 Luminaires and Mounting Bases ColorBurst 6 White 10 Beam Angle 116 000027 02 910503700735 21 Beam Angle 116 000027 00 910503700733 Black 10 Beam Angle 116 000027 03 910503700736 21 Beam Angle 116 000027 01 910503700734 Mounting Base Includes native 60 ft 15 3 m power data cable White 116 000005 00 910503700111 Black 116 000005 01 910503700112 Power Data supplies PDS 150e 24V D...

Page 8: ...4 Horizontal Spread Lens 36 50 120 000027 00 Horizontal Vertical Spread Lens 40 40 120 000027 01 Accessories Designed specifically for ColorBurst 6 Luminaires accessories provide additional options for controlling and dispersing light Accessories attach securely to the ColorBurst 6 accessory attachment ring with the included retention spring and attachment screws The accessory attachment ring prev...

Page 9: ... to each other Refer to the power data supply s Installation Instructions or Specification Sheet for guidelines on configuring and positioning the power data supply in relation to the controller 2 You can install ColorBurst 6 Luminaires to the optional Mounting Base or to a 102 mm 4 in round U S electrical junction box suitable for your application 3 You can connect up to six ColorBurst 6 Luminair...

Page 10: ...ation the included junction box gasket or Mounting Base gasket and contractor grade room temperature vulcanizing RTV silicone sealant as required Install the Luminaires ColorBurst 6 Luminaires can be used freestanding with the Mounting Base or they can be mounted to a wall ceiling or other suitable surface using the Mounting Base or a junction box suitable for your application In wet or damp locat...

Page 11: ...rotect floors or other finished surfaces in freestanding indoor applications The native 18 3 m 60 ft power data cable is sealed to create a water tight junction when used with the included gasket 1 Determine the Luminaire location as specified in the lighting design plan Ensure that the mounting location is free of debris and that the Mounting Base sits flush to the mounting surface 2 If installin...

Page 12: ...ke sure the power is OFF before mounting and connecting ColorBurst 6 Luminaires 1 Pull each Luminaire cable through a knockout in the side of the power data supply 2 Connect line common ground and data to a provided connector then snap the connector into the connector terminal inside the power data supply housing 3 Using wire nuts connect the green ground wire from each Luminaire cable to the eart...

Page 13: ...spread lenses flush against the Luminaire housing 1 Using the included 3 32 in hex key wrench remove the three screws that secure the accessory attachment ring to the Luminaire housing 2 If installing an accessory place it into the front of the Luminaire housing If installing a spread lens place it into the accessory ring and secure it with the retention spring 3 Align the holes on the accessory r...

Page 14: ...work QuickPlay Pro can automatically discover all of your Luminaires controllers and power data supplies for quick configuration In DMX installations you can address and configure your Luminaires using QuickPlay Pro with iPlayer 3 or SmartJack Pro You can manually enter Luminaire serial numbers or you can import a spreadsheet listing each Luminaire s serial number and starting DMX address For comp...

Page 15: ...olor Kinetics logo ColorBlast ColorBlaze ColorBurst eW Fuse ColorGraze ColorPlay ColorReach iW Reach eW Reach DIMand EssentialWhite eW EvenBalance iColor iColor Cove IntelliWhite iW iPlayer Optibin Powercore and PureGlow are either registered trademarks or trademarks of Philips Lighting Holding B V in the United States and or other countries All other brand or product names are trademarks or regis...

Reviews: