background image

ANSI

Std.

Rated Approx.

Approx.

Product

Ordering

Nom.

Code/

Pkg.

LCL

MOL

Avg. Life

Initial

Mean

CCT

Number

Code

Watts

Bulb

Base

Ballast Ref.

Qty.

Description

(In.)

(In.)

Hrs.

1

Lumens

2

Lumens

3

CRI

(K)

13093-0

CDM250S50/V/O/4K/ALTO

250

ED-18

Mog.

M168/O

12

G, Clear,Vertical ±15º (4, 5, 6)

3

4

3

4

20,000

22,500

19,125

85

4000

13094-8

CDM400S51/V/O/4K/ALTO

400

ED-18

Mog.

M169/O

12

G, Clear,Vertical ±15º (4, 5, 6)

3

4

3

4

20,000

34,000

28,900

85

4000

Electrical,Technical and Ordering Data

(Subject to change without notice)

MasterColor

®

Ceramic Metal Halide HPS-Retro White

MasterColor technology optimized to operate in existing HPS fixtures,
which means a simple, twist-of-the-wrist conversion

Improved work environment (crisp white light vs. yellow light)

Better for the environment:TCLP

-compliant

Replace yellow light with white light with just a simple twist!

For operation on HPS ballasts; 85% lumen maintenance

No shut off required in 24-hour-a-day/7-day-a-week operations 
(relamp fixtures at or before the end of rated life)

Warnings, Cautions and Operating Instructions

R

“WARNING:

These lamps can cause serious skin

burn and eye inflammation from short wave ultraviolet

radiation if outer envelope of the lamp is broken or 
punctured. Do not use where people will remain for more
than a few minutes unless adequate shielding or other safety
precautions are used. Certain lamps that will automatically
extinguish when the outer envelope is broken or punctured
are commercially available.”This lamp complies with FDA
radiation performance standard 21 CFR subchapter J.
(USA:21CFR 1040.30 Canada:SOR/DORS/80-381)

If the outer bulb is broken or punctured, turn off
at once and replace the lamp to avoid possible
injury from hazardous short wave ultraviolet 
radiation. Do not scratch the outer bulb or subject
it to pressure as this could cause the outer bulb to
crack or shatter. A partial vacuum in the outer
bulb may cause glass to fly if the envelope is struck.

WARNING:

The arc-tube of metal halide lamps 

are designed to operate under high pressure and at 
temperatures up to 1000º C and can unexpectedly rupture
due to internal or external factors such as a ballast failure or
misapplication. If the arc-tube ruptures for any reason, the
outer bulb may break and pieces of extremely hot glass
might be discharged into the surrounding environment. If
such a rupture were to happen,

THERE IS A RISK OF

PERSONAL INJURY, PROPERTY DAMAGE,
BURNS AND FIRE.

These lamps are designed to retain all the glass
particles should an arc tube rupture occur.The 
following operating instructions are recommended
to minimize these occurrences.

RELAMP FIXTURES AT OR BEFORE THE END OF
RATED LIFE.Allowing lamps to operate until they
fail is not advised and may increase the possibility of
inner arc tube rupture.

This lamp contains an arc tube with a filling gas
containing Kr-85 and is distributed by Philips
Lighting Company, a division of Philips Electronics
North America  Corporation, Somerset, New
Jersey, 08875.

CAUTION:

TO REDUCE THE RISK OF PERSONAL

INJURY, PROPERTY DAMAGE, BURNS AND FIRE 
RESULTING FROM AN ARC-TUBE RUPTURE THE 
FOLLOWING 

LAMP OPERATING INSTRUCTIONS

MUST BE FOLLOWED:

LAMP OPERATING INSTRUCTIONS:

1. RELAMP FIXTURES AT OR BEFORE THE END OF

RATED LIFE. Allowing lamps to operate until they fail is
not advised and may increase the possibility of inner arc
tube rupture.

2. Before lamp installation/replacement, shut power off and

allow lamp and fixture to cool to avoid electrical shock
and potential burn hazards.

3. Use only auxiliary equipment meeting Philips and/or 

ANSI standards. Use within voltage limits recommended
by ballast manufacturer.

A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers

electrical data.

4. Periodically inspect the outer envelope. Replace any 

lamps that show scratches, cracks or damage.

5. If a lamp bulb support is used, be sure to insulate the

support electrically to avoid possible decomposition of
the bulb glass.

6. Protect lamp base, socket and wiring against moisture,

corrosive atmospheres and excessive heat.

7.Time should be allowed for lamps to stabilize in color

when turned on for the first time.This may require 
several hours of operation, with more than one start.
Lamp color is also subject to change under conditions 
of excess vibration or shock and color appearance may
vary between individual lamps.

8. Lamps may require 10 to 20 minutes to re-light if there 

is a power interruption.

9.Take care in handling and disposing of lamps. If an arc

tube is broken, avoid skin contact with any of the 
contents or fragments.

WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Protected MasterColor

®

Ceramic Metal Halide

HPS-Retro White

Lamps ED-18 (Vertical Burn ± 15º, Open or Enclosed Fixtures)

1) Rated average life is the life obtained, on the average,

from large representative groups of lamps in laboratory
tests under controlled conditions at 10 or more operat-
ing hours per start. It is based on survival of at least 50%
of the lamps and allows for individual lamps or groups of
lamps to vary considerably from the average.

2) Approximate lumen values listed are for vertical 

operation of the lamp.

3) Approximate lumen output at 40% of lamp rated average life.

4) Performance may not be satisfactory unless operated

within specified operating positions.

5) Heat resisting glass bulb.

6) MasterColor

®

Metal Halide Lamps are not recommended

for use on dimmers and are not warranted if used on
dimmer systems.

This product utilizes ALTO

®

Lamp Technology. ALTO 

products pass the US EPA's Toxicity Characteristic Leaching
Procedure (TCLP) for non-hazardous waste status.

FOOTNOTES for MasterColor

®

Ceramic Metal Halide HPS-Retro White

®

Lamps

Philips Lighting Company 
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050

A Division of Philips Electronics North America Corporation 

Updated 8/04

P-2220-E

Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050  

A Division of Philips Electronics Ltd.

www.philips.com

Summary of Contents for Ceramalux P-2220-E

Page 1: ... hours rated average life vs 24 000 hours rated average life for standard HPS lamps Extra arc tube provides light instantly after momentary power interruption ALTO High Pressure Sodium Passes EPA s TCLP1 test for non hazardous waste MasterColor HPS Retro White Optimized to operate on a high pressure sodium ballast Replace yellow light with crisp bright white light with just a simple twist 1 The TC...

Page 2: ... to change without notice ANSI Std Rated Approx Approx Product Ordering Nom Code Pkg LCL MOL Avg Life Initial Mean CCT Number Code Watts Bulb Base Ballast Ref Qty Description In In Hrs 1 Lumens2 Lumens3 CRI K 30617 5 C70S62 C M 70 BD 17 Med S62 12 G 4 6 9 12 3 7 16 5 7 16 15 000 4400 3960 60 2200 30635 7 C100S54 C M 100 BD 17 Med S54 12 G 4 6 9 12 3 7 16 5 7 16 15 000 7800 7020 60 2200 30637 3 C10...

Page 3: ...N types and 4000 volts for other sizes 7 C150S55 and C150S56 lamps are not electrically interchangeable Different ballasts are required for the proper operation of each lamp type ANSI type S55 ballast is for the 55 volt normal lamp and the ANSI type S56 ballast is for the 100 volt nominal lamp 8 This lamp should be shielded from moisture to prevent breakage 9 For use in fixtures which do not redir...

Page 4: ...hilips Electronics North America Corporation Somerset New Jersey 08875 CAUTION TO REDUCE THE RISK OF PERSONAL INJURY PROPERTY DAMAGE BURNS AND FIRE RESULTING FROM AN ARC TUBE RUPTURE THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED LAMP OPERATING INSTRUCTIONS 1 RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE Allowing lamps to operate until they fail is not advised and may increase the...

Reviews: