Jumper settings
JUMPERS 1 TO 3 can be used for setting SCSI addresses.
Remark: Jumper detection only by Power on or SCSI hand Reset.
Drive will always supply TERM POWER.
Drive will always generate and check parity on SCSI.
Auto
selftest
EXECUTION
- Selftest will be activated by pushing and holding
OPEN/CLOSE button for one complete Open/Close
cycle of tray.
- At Host command : Send diagnostics.
ADDITIONAL INFORMATION
ID 0
1
2
ADDRESS
0
0
0
0
1
1
0
0
2
0
1
0
3
1
1
0
(DEFAULT) 4
0
0
1
5
1
0
1
6
0
1
1
7
1
1
1
TERM
1
= Termination ON (DEFAULT)
0
= Termination OFF