Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • C0711
Calculite
®
HID Adjustable Accent
C4T4GA-MHT4RF
Page 2 of 4
4 1/2" Aperture, T4.5 Ceramic Metal Halide Glasslite, Flood
(
FC
) is initial footcandles at center of
beam. Beam length (
L
) and beam width (
W
)
are to where the candlepower is reduced
to 50% of the center beam candlepower.
(
C
) is the distance to the center of the
beam.
600
300
900
1,200
30°
60°
1,500
750
2,250
3,000
30°
60°
3,750
7,500
11,250
15,000
30°
60°
30° Aiming Angle
Horizontal Surface
D C
FC L
W
8'
4.6'
161 4.2'
3.6'
10' 5.8'
103 5.2'
4.5'
12' 6.9'
71
6.3'
5.4'
15' 8.7'
46
7.9'
6.7'
20' 11.5' 26
10.5'
9.0'
30° Aiming Angle
Vertical Surface
D C
FC L
W
3'
5.2'
220 5.3'
2.3'
4'
6.9'
124 7.0'
3.1'
6'
10.4'
55 10.5' 4.7'
8'
13.9'
31 14.0' 6.2'
12' 20.8'
14 21.0' 9.3'
30° Aiming Angle
Vertical Surface
D C
FC L
W
2'
3.5'
39 9.1'
2.8'
3'
5.2'
17 13.6' 4.2'
4'
6.9'
10 18.2' 5.7'
6'
10.4'
4
27.2' 8.5'
8'
13.9'
2
36.3' 11.3'
ANGLE WALL
0
143
5
242
10
456
15
865
20 1120
25
1251
30 1136
35
1003
40
823
45
722
50
650
55
465
60
218
65
46
70 12
75
10
80
8
85
5
90
0
ANGLE WALL
0
274
5
488
10
951
15
1753
20
2432
25
2979
30
2993
35
2595
40
1999
45
1534
50
1173
55
649
60
245
65
64
70 26
75
19
80
6
85
0
90
0
ANGLE WALL
0
141
5
288
10
909
15
2640
20
6497
25
12581
30
15817
35
13798
40
9527
45
6823
50
4410
55
1573
60
338
65
45
70
29
75
18
80
11
85
0
90
0
AIMED 30 deg. TOWARD WALL
LAMP: 70W CERAMIC MH, PHILIPS
LUMEN RATING: 6200 LMS.
CBCP: 15817
Beam Angle: 22
AROMAT 70W ELECTRONIC BALLAST
DATE: APR 14, 2004
CERTIFIED TEST REPORT NO. 18688
AIMED 30 deg. TOWARD WALL
LAMP: 39W CERAMIC MH, PHILIPS
LUMEN RATING: 3400 LMS.
CBCP: 2993
Beam Angle: 32
AROMAT 39W ELECTRONIC BALLAST
DATE: APR 13, 2004
CERTIFIED TEST REPORT NO. 18687
AIMED 30 deg. TOWARD WALL
LAMP: 20W CERAMIC MH, GE
LUMEN RATING: 1700 LMS.
CBCP: 1251
Beam Angle: 39
AROMAT 20W ELECTRONIC BALLAST
DATE: APR 15, 2004
CERTIFIED TEST REPORT NO. 18686
30° Aiming Angle
Horizontal Surface
D C
FC L
W
6'
3.5'
23
5.9'
4.9'
8'
4.6'
13
7.9'
6.5'
10' 5.8'
8
9.9'
8.2'
12' 6.9'
6
11.8'
9.8'
15' 8.7'
4
14.8'
12.3'
30° Aiming Angle
Horizontal Surface
D C
FC L
W
8'
4.6'
30
6.3'
5.3'
10' 5.8'
19
7.9'
6.6'
12' 6.9'
14
9.4'
7.9'
15' 8.7'
9
11.8'
9.9'
20' 11.5' 5
15.7'
13.2'
30° Aiming Angle
Vertical Surface
D C
FC L
W
3'
5.2'
42 9.1'
3.4'
4'
6.9'
23 12.2' 4.6'
6'
10.4'
10 18.3' 6.9'
8'
13.9'
6
24.4' 9.2'
12' 20.8'
3
36.5' 13.8'
Candlepower Distribution 20W T4.5 - Flood Reflector
Candlepower Distribution 39W T4.5 - Flood Reflector
Candlepower Distribution 70W T4.5 - Flood Reflector