Service Modes, Error Codes, and Fault Finding
EN 24
BJ3.0E PA
5.
Figure 5-5 “Off” to “Semi Stand-by” flowchart (part 3)
G_15960_118c.eps
100306
Yes
MIPS reads the wake up reason
from standby µP.
Semi-Standby
MPIF's should be initialized according the FMS information.
MPIF should deliver 2 observers:
POR= 0; normal operation
ROK = 1; reference frequency is present (coming from AVIP)
(AVIP's need to be started before the MPIF's in order to have a good clock distribution).
AVIP default power-up mode is Standby. The Viper instructs AVIP via I²C to enable all the
PLL's and clocks and hence enter to Full Power mode. See FMS AVIP for further details
and the rest of the initialization.
initialize tuners and Hirate according FMS
information
All observers present with correct state?
Log appropriate
Observer error
No
Yes
Initialize video processing IC's according FMS information:
- Spider
Initialize source selection according FMS
and CHS information
initialize Columbus by triggering CHS Columbus Init interface
initialize 3D Combfilter by triggering CHS 3D Comb filter Init interface
initialize AutoTV by triggering CHS AutoTV Init interface
See appropriate CHS documents for further details.
3-th try?
Log Code as
error code
SP
Enable Alive check mechanism
Wait until Viper starts to
communicate
Viper SW initialization
succeeded
within 20s?
No
Switch POD-MODE and ON-MODE
I/O line high.
Yes
initialize PNX2015 HD subsystem according
FMS information
Disable all supply related protections and
switch off the +2V5, +3V3 DC/DC converter.
switch off the remaining DC/DC
converters
Wait 5ms
Switch Viper in reset
FHP PDP
Set?
Yes
No
Init FHP PDP by triggering
CHS displays
Initialize_display interface
Switch PDPGO low
Send STBYEN = 1
PFCON = 1
VCCON = 1
to PDP display (I²C)
Wait 10ms
Switch the NVM reset
line HIGH.
Wait for the +8V6 to be detected if not yet present. (if
it does not come, the standby µP will enter a
protection mode, this is not a dead end here)
Start 4 seconds preheating timer in case of
an LPL scanning backlight LCD set.
Do not enter semi-standby state in case of an LPL
scanning backlight LCD set before 4s preheating timer has
elapsed.
Flash to Ram image
transfer succeeded
within 30s?
No
Yes
Code = 53
Code = 5
Initialize Ambilight with Lights off.
- Register PIIConfig of the Pacific3: LVDS function should be set to 0
(CMOS input) in the Baby Jaguar platform.
- POIConfig: lvds function should be set to 0 (CMOS out on Baby)
- PanelConfig register: PanelOff = 0, PanelOn = 1. P3 can always be
on, switching of lvds is done through PNX.
Initialize Pacific related Ambilight settings
(if applicable)
Because of a bug in the Pacific IC, all video and
display related Pacific parameters should be
initialized before initializing the ambilight related
Pacific parameters. If not, initializing the video and
display related Pacific parameters will overwrite the
ambilight parameters.
From part B
From part B
From part B
From part A
action holder: MIPS
autonomous action
action holder: St-by