2 EN
— If the filter is not used for 2 days, let the water run about a minute before
use again.
— If the filter is not used for more than a week, remove and drain the cartridge.
Wrap and store it in the chiller of the fridge. Let the water run for 3 minutes
before use again.
— If the filter has been used for a long time and water flow obviously decreases,
remove the cartridge and shake it, then flush it with water from both ends.
— Replace the cartridge every 6 to 12 months based on the tap water quality
and usage frequency. The model number is AWP175.
3 Maintenance
— This product is for tap water only. Do not use water of unknown source.
— Do not install it if the water supply is with water pressure exceeding 0.4MPa.
— If the pressure exceeds 0.4MPa, pressure-reducing valve should be added
which needs to be purchased separately.
— The inlet water temperature should be 5-60°C, otherwise the cartridge will
be damaged.
— The water treated by this product is for showering only. Do not drink the
water filtered by it.
— The cartridge can only be cleaned with water. No detergents should be
used because they will damage the filter."
4 Precautions
This product includes a 2-year warranty from the date of purchase. For more
detail about warranty conditions, please visit: www.Philips.com.
Within two years from the date of purchase, you will receive free warranty
against defects in materials and workmanship, when used in compliance with
the user manual and confirmed by our maintenance service.
The warranty service does not include frequent replaced consumable
components (filter cartridge, granular activated carbon, ion exchange resin,
hollow fiber membrane, etc.), auxiliary devices, transportation fee and
door-to-door service.
5 Warranty
1 EN
This product is mainly used for shower filtraion. Municipal tap water is used
as water supply. It does not need door-to-door installation. Please install it
according to this user manual.
1 Product Introduction
2 Installation
3
4
2
1
Take out the filter cartridge
and remove the covers at
both ends of the cartridge.
Put the cartridge back in the case.
Turn on the tap for 2-3 minutes
to check if there is any leakage.
Connect the hose to the water outlet
end of the filter.
Remove the hose from the water
mixing valve, and connect and tighten
the shower filter with the valve from
the water inlet end.
1
2
2
4
1
3