Approx.
Rated
Color
Color
Nominal
Product
Ordering
Product
Ordering
Length
Initial
Design
Average
Temp.
Rendering
Watts
Number
Code
Number
Code
Bulb
(In.)
Lumens
1
Lumens
2
Life (Hrs.)
3
(Kelvin)
Index (CRI)
34
23775-0
F34/SPEC30/RS/EW/ALTO
14253-9
F34T12/830/EW/ALTO
T12
48
2800
2660
20,000
3000
82
34
23777-6
F34/SPEC35/RS/EW/ALTO
14254-7
F34T12/835/EW/ALTO
T12
48
2800
2660
20,000
3500
82
34
23779-2
F34/SPEC41/RS/EW/ALTO
14255-4
F34T12/841/EW/ALTO
T12
48
2800
2660
20,000
4100
82
34
Now Available >
14256-2
F34T12/850/EW/ALTO
T12
48
2650
2520
20,000
5000
82
40
27311-0
F40/SPEC30/ALTO
14261-2
F40T12/830/ALTO
T12
48
3200
3040
20,000
3000
82
40
27291-4
F40/SPEC35/ALTO
14262-0
F40T12/835/ALTO
T12
48
3200
3040
20,000
3500
82
40
27295-5
F40/SPEC41/ALTO
14263-8
F40T12/841/ALTO
T12
48
3200
3040
20,000
4100
82
40
Now Available >
14264-6
F40T12/850/ALTO
T12
48
3050
2900
20,000
5000
82
Electrical,Technical and Ordering Data
(Subject to change without notice)
Philips 800 Series T12 Fluorescent Lamps Featuring ALTO
®
Lamp Technology
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Printed in USA 6/05
P-1373-G
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
Old Product:
SPEC
New Product:
Philips 800 Series Lamps
1) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions.
For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier applied to the
designated lamp lumen output.
2) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.
3) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
E
N
VIR
O N M
EN
T
B
E
TT
ER FOR T
H
E
†
†
This fluorescent lamp is better for the environment because of its reduced mercury content. All fluorescent lamps
contain mercury for effective operation, however, Philips lamps with ALTO
®
Lamp Technology average 70% less
mercury than the 2001 industry average for fluorescent lamps up to sixty inches which are not TCLP-compliant.