background image

LightPack LED Module

Installation & Operation Guide

7

SETTING MODES AND DMX512 ADDRESS

The operating modes and DMX512 address can be easily configured using the controls located
inside the recess panel. There is one 4-position DIP switch (Configuration Switch) to
configure the modes and three rotary DIP switches to configure the DMX512 address. 

For example (as shown in 

Figure 7

), to set a DMX512 address of 471, set the 100’s dial to "4",

the 10’s dial to "7", and the 1’s dial to "1". To configure the modes, set each of the DIP
switches to either the ON or OFF setting (up or down).

Figure 7:  DIP Switches

To program individual DMX512 address, 8/16 Bit Mode, and Intensity Channel for each
connected luminaire:

Step

1. At Configuration Switch, set Switch 4 to “ON”. 

Step

2. At Configuration Switch, set 8 /16 Bit Mode and Intensity channel switches as 

desired.

Step

3. Set each DMX address dial to desired DMX512 address for first luminaire. 

Step

4. Press and hold Focus / Bump button until first luminaire flashes.

Step

5. Set each DMX address dial to desired DMX512 address for second luminaire. 

Step

6. Press and hold Focus / Bump button until second luminaire flashes (about 5 

seconds).

Step

7. When programming is complete, at Configuration Switch, set Switch 4 to “OFF”.

Configuration Switch

ON = Program On
OFF = Program Off

For Future Use

ON = Intensity Channel On
OFF = Intensity Channel Off

ON = 16-Bit Mode
OFF = 8-Bit Mode

DMX512 Address Switches

000 = DMX Disabled (only 
Focus / Bump Button active)

001 - 512 = DMX512 Address

Summary of Contents for 71361

Page 1: ......

Page 2: ...rand Lighting n assume aucune responsibilité sur toute erreur ou ommission inscrite dans ce manuel Pour tous commentaires ou suggestions concernant des corrections et ou les mises à jour de ce manuel veuillez s ll vous plait contacter le bureau de Strand Lighting le plus proche Information contained in this document may not be duplicated in full or in part by any person without prior written appro...

Page 3: ...quipment for other than intended use g Refer service to qualified personnel SAVE THESE INSTRUCTIONS WARNING You must have access to a main circuit breaker or other power disconnect device before installing any wiring Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation Installing the device with power on may expose you to dangerous voltag...

Page 4: ...t this Guide 3 ACCESSORIES 3 Clamps 3 DMX512 Termination 3 OVERVIEW 4 INSTALLATION 5 Wall Mounting 5 Pipe Mounting 5 CONNECTING POWER 6 CONNECTING DATA 6 DMX512 Connections 6 LED Luminaire Port Connections 6 SETTING MODES AND DMX512 ADDRESS 7 OPERATION 8 LightPack LED Controller Status LED Indicators 8 Focus Bump Button Operation 8 Luminaire Discovery 8 SPECIFICATIONS 9 ...

Page 5: ...isconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control It is recommended that a qualified electrician perform this installation Observe the following precautions when installing operating or servicing the product Disconnect power before servicing Install in dry locations only DO NOT power module from a dimmed source Connect to standard power or mechanical...

Page 6: ... exactly the right number of control channels needed An intensity channel set up option is also available to make your luminaires even easier to use and program CAUTION The LightPack LED Module is for use with specified LED luminaires only NOT FOR USE WITH SCROLLERS For luminaire types refer to SPECIFICATIONS on page 9 Figure 1 LightPack LED Module Overview 1 5 6 3 4 2 7 8 9 SIDE VIEW END VIEW END...

Page 7: ...unit will dissipate heat properly Mounting to wall must comply with local and national codes Figure 2 LightPack LED Module Wall Mounting Pipe Mounting The LightPack LED Module can be mounted on pipe or truss Note that the pipe mount with screws are included with unit Clamps are sold separately or by others See Clamps on page 3 for ordering information The unit must be mounted with the heatsink fin...

Page 8: ...uminaire Port Connections The LightPack LED Module supports the control of two LED luminaires through its two LED Luminaire ports To AC Power AC Input Wiring 230V Models Wire Color Description Brown Line Blue Neutral Green Yellow Ground AC Input Wiring 120V Models Wire Color Description Black Line White Neutral Green Ground DMX 5 Pin Connectors Pinout Pin Signal 1 Common Drain 2 DMX512 3 DMX512 4 ...

Page 9: ... Mode and Intensity Channel for each connected luminaire Step 1 At Configuration Switch set Switch 4 to ON Step 2 At Configuration Switch set 8 16 Bit Mode and Intensity channel switches as desired Step 3 Set each DMX address dial to desired DMX512 address for first luminaire Step 4 Press and hold Focus Bump button until first luminaire flashes Step 5 Set each DMX address dial to desired DMX512 ad...

Page 10: ... Module is set by default for RGBAW LED luminaire operation If you plug in an RGB or WW LED luminaire you will need to cycle through the Focus Bump button presses as described in Focus Bump Button Operation to return to the first color The LightPack LED Module can discover and set itself to control the type of connected luminaire To Discover the connected luminaire Step 1 Connect luminaire to Ligh...

Page 11: ...2 lbs 1 9 kg DMX512 Connections DMX512 In Out thru Output Connections 2 power and data on each Temperature 32 to 122 F 0 to 50 C Humidity Range 5 to 95 Non condensing Standards Compliance ETL cETL listed and CE marked Figure 8 Dimensions C 9 62 in 244 35 mm SIDE VIEW 3 25 in 82 55 mm END VIEW DMX Connectors AC Input BOTTOM VIEW Accessory Mounting Points 2 50 in 63 50 mm 8 56 in 217 43 mm 4 17 in 1...

Page 12: ...Installation Operation Guide LightPack LED Module 10 Part No 2 450226 010 ...