![Philips 71361 Installation & Operation Manual Download Page 8](http://html.mh-extra.com/html/philips/71361/71361_installation-and-operation-manual_294517008.webp)
Installation & Operation Guide
LightPack LED Module
6
CONNECTING POWER
The LightPack LED Module is supplied with an AC input cable. Some versions are sold with
AC input connectors installed.
WARNING:
DO NOT power module from a dimmed source. Connect to standard
power or mechanical relay ONLY.
Figure 4: AC Power Connection
ing.com
CONNECTING DATA
DMX512 Connections
The LightPack LED Module supports standard USITT DMX512/1990 protocol. A termination
plug (Strand # 71346) is required at the last module in the data link.
Figure 5: DMX512 Connections
LED Luminaire Port Connections
The LightPack LED Module
supports the control of two LED
luminaires through its two LED
Luminaire ports.
To AC Power
AC Input Wiring - 230V Models
Wire Color
Description
Brown
Line
Blue
Neutral
Green/Yellow
Ground
AC Input Wiring - 120V Models
Wire Color
Description
Black
Line
White
Neutral
Green
Ground
DMX 5-Pin Connectors Pinout:
Pin
Signal
1
Common (Drain)
2
DMX512 -
3
4
No Connection
5
No Connection
DMX512 Out/Thru Cable
or
Termination Plug
DMX512 In Cable
2
3
4
1
LED Module 4-Pin Connector Pinout:
Pin
Signal
1
+24 Volts DC
2
Not Used
3
Data
4
Ground
Figure 6: LED Luminaire Connections
WARNING:
The LightPack
LED Module is only for use with
certain LED luminaires. See
"SPECIFICATIONS" on page 9
for more information.