19
English
English
Error
code
Problem
Possible solution
01
The coffee funnel is
clogged.
Switch off the machine and unplug it. Remove the brew group.
Then open the lid of the pre-ground coffee compartment and
insert the spoon handle. Move the handle up and down until
the clogged ground coffee falls down. Visit
www.philips.com/coffee-care
for detailed video instructions.
03
The brew group is dirty
or not well-greased.
Switch off the machine. Rinse the brew group with fresh water,
let it air-dry and then lubricate it. Consult chapter 'Cleaning the
brew group' or visit
www.philips.com/coffee-care
for detailed
video instructions. Then switch the machine on again.
04
The brew group is not
positioned correctly.
Switch off the machine. Remove the brew group and reinsert it.
Make sure that the brew group is in the correct position before
you insert it. Consult chapter 'Handling the brew group or visit
www.philips.com/coffee-care
for detailed video instructions.
Then switch the machine on again.
05
There is air in the water
circuit.
Restart the machine by switching it off and on again. If this
works, dispense 2-3 cups of hot water. Descale the machine if
you have not done so for a longer period of time.
The AquaClean filter
was not prepared
properly before
installation or it is
clogged.
Remove the AquaClean filter and try again to brew a coffee. If
this works, make sure that the AquaClean filter is prepared
properly before you place it back. Put the AquaClean filter
back into the water tank. If this still does not work, the filter
might be clogged and needs to be replaced.
11
Machine needs to
adjust to room
temperature
Allow some time for the machine to adjust from
transport/outdoor temperature to room temperature. Switch
off the machine for 30 minutes and switch it on again. If this
does not work, contact the Consumer Care Center in your
country. For contact details, see the warranty leaflet.
14
The machine is
overheated.
Switch the machine off and switch it back on again after 30
minutes.
Troubleshooting table
This chapter summarizes the most common problems you could encounter with the machine. Support
videos and a complete list of frequently asked questions are available on
www.philips.com/coffee-
care
. If you are unable to solve the problem, contact the Consumer Care Center in your country. For
contact details, see the warranty leaflet.
Problem
Cause
Solution
There are some coffee
residues inside my new
coffee machine.
This machine has been tested
with coffee.
Although it has been carefully cleaned,
there may be some coffee residues left.
However, the machine is absolutely
new.
Summary of Contents for 5400 Series
Page 2: ......
Page 3: ...A2 A1 A3 A4 A14 A8 A7 A6 A9 A12 A13 A10 A11 A5 A17 A15 A A20 A18 A16 A19 A21 A22 A23 A24 ...
Page 44: ...fillpage Saeco ...
Page 45: ...inside back page ...
Page 47: ...25 26 27 28 29 30 31 32 33 34 35 36 2 1 37 5 sec 38 30 sec 39 40 1 2 41 ...
Page 48: ...inside back page ...
Page 49: ......